
BinTec CAPI Software System

איבערview
CAPI 1.1 and CAPI 2.0 info values with their appropriate error-codes associated with the capiInfoNumber field are as follows. Both CAPI 1.1 and 2.0 info values are arranged by error class.
CAPI 1.1 Info Values
Error Class 10
Formal error messages and errors during management of Message Queues.
| 0x1001 | Application registration error |
| 0x1002 | Wrong application id |
| 0x1003 | Message error |
| 0x1004 | Wrong capi command |
| 0x1005 | Message queue full |
| 0x1006 | Message queue empty |
| 0x1007 | Messages lost |
| 0x1008 | Error during deinstallation |
Error Class 20
Addressing errors.
| 0x2001 | Wrong controller |
| 0x2002 | Wrong PLCI |
| 0x2003 | Wrong NCCI |
| 0x2004 | פאַלש טיפּ |
Error Class 31
Incorrect parameters.
| 0x3101 | B-channel incorrectly coded |
| 0x3102 | Info mask incorrectly coded |
| 0x3103 | Service SI mask incorrectly coded |
| 0x3104 | Service EAZ mask incorrectly coded |
| 0x3105 | B2 protocol incorrect |
| 0x3106 | Dlpd incorrect |
| 0x3107 | B3 protocol incorrect |
| 0x3108 | NCPD incorrect |
| 0x3109 | NCPI incorrect |
| 0x310אַ | Flags incorrectly coded |
Error Class 32
Unsupported parameters.
| 0x3201 | קאָנטראָללער טעות |
| 0x3202 | Conflict between registrations |
| 0x3203 | Function is not supported |
| 0x3204 | PLCI not active |
| 0x3205 | NCCI not active |
| 0x3206 | B2 protocol not supported |
| 0x3207 | Change of B2 protocol not possible in this state |
| 0x3208 | B3 protocol not supported |
| 0x3209 | Change of B3 protocol not possible in this state |
| 0x320אַ | Parameters used not supported in DLPD |
| 0x320b | Parameters used not supported in NCPD |
| 0x320c | Parameters used not supported in NCPI |
| 0x320d | Data length not supported |
| 0x320e | DTMF number unknown |
Error Class 33
Network errors.
| 0x3301 | Error on setup of D-channel layer 1 |
| 0x3302 | Error on setup of D-channel layer 2 |
| 0x3303 | Error on setup of B-channel layer 1 |
| 0x3304 | Error on setup of B-channel layer 2 |
| 0x3305 | Abort D-channel layer 1 |
| 0x3306 | Abort D-channel layer 2 |
| 0x3307 | Abort D-channel layer 3 |
| 0x3308 | Abort B-channel layer 1 |
| 0x3309 | Abort B-channel layer 2 |
| 0x330אַ | Abort B-channel layer 3 |
| 0x330b | Re-establish B-channel layer 2 |
| 0x330c | Re-establish B-channel layer 3 |
Error Class 34
Network messages (whereby xx refers to the related 1TR6 Error-Cause).
| 0x3400 | Normal call clearing |
| 0x3480 | Normal call clearing |
| 0x3481 | Invalid call reference value |
| 0x3483 | Bearer service not implemented |
| 0x3487 | Call identity does not exist |
| 0x3488 | Call identity in use |
| 0x348אַ | No channel available |
| 0x3490 | Requested facility not implemented |
| 0x3491 | Requested facility not subscribed |
| 0x34a0 | Outgoing calls barred |
| 0x34a1 | באַניצער פאַרנומען |
| 0x34a2 | Negative GBG Comparison |
| 0x34a5 | As SPV not aloud |
| 0x34b0 | Reverse charging not allowed at origination |
| 0x34b1 | Reverse charging not allowed at destination |
| 0x34b2 | Reverse charging rejected |
| 0x34b5 | Destination not obtainable |
| 0x34b8 | Number changed |
| 0x34b9 | ארבעט נישט |
| 0x34ba | User not responding |
| 0x34bb | User access busy |
| 0x34bd | Incoming calls barred |
| 0x34be | רופן פארווארפן |
| 0x34d9 | נעץ קאַנדזשעסטשאַן |
| 0x34da | Remote user initiated |
| 0x34f0 | Local procedure error |
| 0x34f1 | Remote procedure error |
| 0x34f2 | Remote user suspended |
| 0x34f3 | Remote user resumed |
| 0x34ff | User info discarded locally |
Error Class 40
FAX-G3 Errors.
| 0x4001 | Remote station is not a fax G3 machine |
| 0x4002 | Local fax module busy |
| 0x4003 | Disconnected during transfer (remote abort) |
| 0x4004 | Disconnected before transfer (training error) |
| 0x4005 | Disconnected during transfer (local tx data underrun) |
| 0x4006 | Fax module temporary disabled |
| 0x4007 | Local disconnect (local abort) |
| 0x4008 | Disconnect during transfer (remote procedure error) |
| 0x4009 | Remote disconnect (remote abort) |
| 0x400אַ | Line Disconnect during transfer |
| 0x400b | Disconnect before transfer |
| 0x400c | Local Disconnect (SFF coding error) |
CAPI 2.0 Info Values
Error Class 00
Informative values (corresponding message was processed).
| 0x0001 | NCPI not supported by current protocol, NCPI ignored |
| 0x0002 | Flags not supported by current protocol, flags ignored |
| 0x0003 | Alert already sent by another application |
Error Class 10
Error information concerning CAPI_REGISTER.
| 0x1001 | צו פיל אַפּליקאַציעס |
| 0x1002 | Logical block size too small, must be at least 128 bytes |
| 0x1003 | Buffer exceeds 64 kByte |
| 0x1004 | Message buffer size too small, must be at least 1024 byte |
| 0x1005 | Max. number of logical connections not supported |
| 0x1006 | רעזערווירט |
| 0x1007 | The message could not be accepted because of an internal busy condition |
| 0x1008 | OS Resource error (e.g. no memory) |
| 0x1009 | COMMON-ISDN-API not installed |
| 0x100אַ | Controller does not support external equipment |
| 0x100b | Controller does only support external equipment |
Error Class 11
Error information concerning message exchange functions.
| 0x1101 | Illegal application number |
| 0x1102 | Illegal command or subcommand or message length less than 12 octets |
| 0x1103 | The message could not be accepted because of a queue full condition |
| 0x1104 | Queue is empty |
| 0x1105 | Queue overflow, a message was lost |
| 0x1106 | Unknown notification parameter |
| 0x1107 | The message could not be accepted because of an internal busy condition |
| 0x1108 | OS resource error (e.g. no memory) |
| 0x1109 | COMMON-ISDN-API not installed |
| 0x110אַ | Controller does not support external equipment |
| 0x110b | Controller does only support external equipment |
Error Class 20
Error information concerning resource/coding problems.
| 0x2001 | Message not supported in current state |
| 0x2002 | Illegal Controller/PLCI/NCCI |
| 0x2003 | Out of PLCI |
| 0x2004 | Out of NCCI |
| 0x2005 | Out of LISTEN |
| 0x2006 | Out of FAX resources (protocol T.30) |
| 0x2007 | Illegal Message parameter coding |
Error Class 30
Error information concerning requested services.
| 0x3001 | B1 protocol not supported |
| 0x3002 | B2 protocol not supported |
| 0x3003 | B3 protocol not supported |
| 0x3004 | B1 protocol parameter not supported |
| 0x3005 | B2 protocol parameter not supported |
| 0x3006 | B3 protocol parameter not supported |
| 0x3007 | B protocol combination not supported |
| 0x3008 | NCPI not supported |
| 0x3009 | CIP Value unknown |
| 0x300אַ | Flags not supported (reserved bits) |
| 0x300b | Facility not supported |
| 0x300c | Data length not supported by correct protocol |
| 0x300d | Reset procedure not supported by current protocol |
Error Class 33
Protocol error reasons.
- 0x3301 Protocol error layer 1 (broken line or B-channel removed by signaling protocol)
- 0x3302 Protocol error layer 2
- 0x3303 Protocol error layer 3
- 0x3304 Another application got that call
- 0x3311 Connecting not successful (remote station is no FAX G3 machine)
- 0x3312 Connecting not successful (training error)
- 0x3313 Disconnected before transfer (remote station does not support transfer mode, e.g. resolution)
- 0x3314 Disconnected during transfer (remote abort)
- 0x3315 Disconnected during transfer (remote procedure error, e.g. unsuccessful repetition of T.30 commands)
- 0x3316 Disconnected during transfer (local tx data underrun)
- 0x3317 Disconnected during transfer (local rx data overflow)
- 0x3318 Disconnected during transfer (local abort)
- 0x3319 Illegal parameter coding (e.g. SFF coding error)
Error Class 34
Disconnect cause from the network according to ETS 300102-1/Q.931. In the field ‘xx’ the cause value received within a cause information element (octet 4) from the network is indicated.
- 0x3481 Unallocated (unassigned) number
- 0x3482 No route to specified transit network
- 0x3483 No route to destination
- 0x3486 Channel unacceptable
- 0x3487 Call awarded and being delivered in an established channel
- 0x3490 Normal call clearing
- 0x3491 User busy
- 0x3492 No user responding
- 0x3493 No answer from user (user alerted)
- 0x3495 Call rejected
- 0x3496 Number changed
- 0x349a Non-selected user clearing
- 0x349b Destination out of order
- 0x349c Invalid number format
- 0x349d Facility rejected
- 0x349e Response to STATUS ENQUIRY
- 0x349f Normal, unspecified
- 0x34a2 No circuit / channel available
- 0x34a6 Network out of order
- 0x34a9 Temporary failure
- 0x34aa Switching equipment congestion
- 0x34ab Access information discarded
- 0x34ac Requested circuit / channel not available
- 0x34af Resources unavailable, unspecified
- 0x34b1 Quality of service unavailable
- 0x34b2 Requested facility not subscribed
- 0x34b9 Bearer capability not authorized
- 0x34ba Bearer capability not presently available
- 0x34bf Service or option not available, unspecified
- 0x34c1 Bearer capability not implemented
- 0x34c2 Channel type not implemented
- 0x34c5 Requested facility not implemented
- 0x34c6 Only restricted digital information bearer capability is available
- 0x34cf Service or option not implemented, unspecified
- 0x34d1 Invalid call reference value
- 0x34d2 Identified channel does not exist
- 0x34d3 A suspended call exists, but this call identity does not
- 0x34d4 Call identity in use
- 0x34d5 No call suspended
- 0x34d6 Call having the requested call identity has been cleared
- 0x34d8 Incompatible destination
- 0x34db Invalid transit network selection
- 0x34df Invalid message, unspecified
- 0x34e0 Mandatory information element is missing
- 0x34e1 Message type non-existent or not implemented
- 0x34e2 Message not compatible with call state or message type non-existent or not implemented
- 0x34e3 Information element non-existent or not implemented
- 0x34e4 Invalid information element contents
- 0x34e5 Message not compatible with call state
- 0x34e6 Recovery on timer expiry
- 0x34ef Protocol error, unspecified
- 0x34ff Interworking, unspecified
דאָקומענטן / רעסאָורסעס
![]() | CAPI Software System |
רעפערענצן
- באַניצער מאַנואַלmanual.tools

