BinTec CAPI Software System Owner’s Manual

BinTec CAPI Software System Owner’s Manual

BinTec-logo

BinTec CAPI Software System

BinTec-CAPI-Software-System-product-image

איבערview

CAPI 1.1 and CAPI 2.0 info values with their appropriate error-codes associated with the capiInfoNumber field are as follows. Both CAPI 1.1 and 2.0 info values are arranged by error class.

CAPI 1.1 Info Values

Error Class 10
Formal error messages and errors during management of Message Queues.

0x1001 Application registration error
0x1002 Wrong application id
0x1003 Message error
0x1004 Wrong capi command
0x1005 Message queue full
0x1006 Message queue empty
0x1007 Messages lost
0x1008 Error during deinstallation

Error Class 20
Addressing errors.

0x2001 Wrong controller
0x2002 Wrong PLCI
0x2003 Wrong NCCI
0x2004 פאַלש טיפּ

Error Class 31
Incorrect parameters.

0x3101 B-channel incorrectly coded
0x3102 Info mask incorrectly coded
0x3103 Service SI mask incorrectly coded
0x3104 Service EAZ mask incorrectly coded
0x3105 B2 protocol incorrect
0x3106 Dlpd incorrect
0x3107 B3 protocol incorrect
0x3108 NCPD incorrect
0x3109 NCPI incorrect
0x310אַ Flags incorrectly coded

Error Class 32
Unsupported parameters.

0x3201 קאָנטראָללער טעות
0x3202 Conflict between registrations
0x3203 Function is not supported
0x3204 PLCI not active
0x3205 NCCI not active
0x3206 B2 protocol not supported
0x3207 Change of B2 protocol not possible in this state
0x3208 B3 protocol not supported
0x3209 Change of B3 protocol not possible in this state
0x320אַ Parameters used not supported in DLPD
0x320b Parameters used not supported in NCPD
0x320c Parameters used not supported in NCPI
0x320d Data length not supported
0x320e DTMF number unknown

Error Class 33
Network errors.

0x3301 Error on setup of D-channel layer 1
0x3302 Error on setup of D-channel layer 2
0x3303 Error on setup of B-channel layer 1
0x3304 Error on setup of B-channel layer 2
0x3305 Abort D-channel layer 1
0x3306 Abort D-channel layer 2
0x3307 Abort D-channel layer 3
0x3308 Abort B-channel layer 1
0x3309 Abort B-channel layer 2
0x330אַ Abort B-channel layer 3
0x330b Re-establish B-channel layer 2
0x330c Re-establish B-channel layer 3

Error Class 34
Network messages (whereby xx refers to the related 1TR6 Error-Cause).

0x3400 Normal call clearing
0x3480 Normal call clearing
0x3481 Invalid call reference value
0x3483 Bearer service not implemented
0x3487 Call identity does not exist
0x3488 Call identity in use
0x348אַ No channel available
0x3490 Requested facility not implemented
0x3491 Requested facility not subscribed
0x34a0 Outgoing calls barred
0x34a1 באַניצער פאַרנומען
0x34a2 Negative GBG Comparison
0x34a5 As SPV not aloud
0x34b0 Reverse charging not allowed at origination
0x34b1 Reverse charging not allowed at destination
0x34b2 Reverse charging rejected
0x34b5 Destination not obtainable
0x34b8 Number changed
0x34b9 ארבעט נישט
0x34ba User not responding
0x34bb User access busy
0x34bd Incoming calls barred
0x34be רופן פארווארפן
0x34d9 נעץ קאַנדזשעסטשאַן
0x34da Remote user initiated
0x34f0 Local procedure error
0x34f1 Remote procedure error
0x34f2 Remote user suspended
0x34f3 Remote user resumed
0x34ff User info discarded locally

Error Class 40
FAX-G3 Errors.

0x4001 Remote station is not a fax G3 machine
0x4002 Local fax module busy
0x4003 Disconnected during transfer (remote abort)
0x4004 Disconnected before transfer (training error)
0x4005 Disconnected during transfer (local tx data underrun)
0x4006 Fax module temporary disabled
0x4007 Local disconnect (local abort)
0x4008 Disconnect during transfer (remote procedure error)
0x4009 Remote disconnect (remote abort)
0x400אַ Line Disconnect during transfer
0x400b Disconnect before transfer
0x400c Local Disconnect (SFF coding error)

CAPI 2.0 Info Values

Error Class 00
Informative values (corresponding message was processed).

0x0001 NCPI not supported by current protocol, NCPI ignored
0x0002 Flags not supported by current protocol, flags ignored
0x0003 Alert already sent by another application

Error Class 10
Error information concerning CAPI_REGISTER.

0x1001 צו פיל אַפּליקאַציעס
0x1002 Logical block size too small, must be at least 128 bytes
0x1003 Buffer exceeds 64 kByte
0x1004 Message buffer size too small, must be at least 1024 byte
0x1005 Max. number of logical connections not supported
0x1006 רעזערווירט
0x1007 The message could not be accepted because of an internal busy condition
0x1008 OS Resource error (e.g. no memory)
0x1009 COMMON-ISDN-API not installed
0x100אַ Controller does not support external equipment
0x100b Controller does only support external equipment

Error Class 11
Error information concerning message exchange functions.

0x1101 Illegal application number
0x1102 Illegal command or subcommand or message length less than 12 octets
0x1103 The message could not be accepted because of a queue full condition
0x1104 Queue is empty
0x1105 Queue overflow, a message was lost
0x1106 Unknown notification parameter
0x1107 The message could not be accepted because of an internal busy condition
0x1108 OS resource error (e.g. no memory)
0x1109 COMMON-ISDN-API not installed
0x110אַ Controller does not support external equipment
0x110b Controller does only support external equipment

Error Class 20
Error information concerning resource/coding problems.

0x2001 Message not supported in current state
0x2002 Illegal Controller/PLCI/NCCI
0x2003 Out of PLCI
0x2004 Out of NCCI
0x2005 Out of LISTEN
0x2006 Out of FAX resources (protocol T.30)
0x2007 Illegal Message parameter coding

Error Class 30
Error information concerning requested services.

0x3001 B1 protocol not supported
0x3002 B2 protocol not supported
0x3003 B3 protocol not supported
0x3004 B1 protocol parameter not supported
0x3005 B2 protocol parameter not supported
0x3006 B3 protocol parameter not supported
0x3007 B protocol combination not supported
0x3008 NCPI not supported
0x3009 CIP Value unknown
0x300אַ Flags not supported (reserved bits)
0x300b Facility not supported
0x300c Data length not supported by correct protocol
0x300d Reset procedure not supported by current protocol

Error Class 33
Protocol error reasons.

  • 0x3301 Protocol error layer 1 (broken line or B-channel removed by signaling protocol)
  • 0x3302 Protocol error layer 2
  • 0x3303 Protocol error layer 3
  • 0x3304 Another application got that call
  • 0x3311 Connecting not successful (remote station is no FAX G3 machine)
  • 0x3312 Connecting not successful (training error)
  • 0x3313 Disconnected before transfer (remote station does not support transfer mode, e.g. resolution)
  • 0x3314 Disconnected during transfer (remote abort)
  • 0x3315 Disconnected during transfer (remote procedure error, e.g. unsuccessful repetition of T.30 commands)
  • 0x3316 Disconnected during transfer (local tx data underrun)
  • 0x3317 Disconnected during transfer (local rx data overflow)
  • 0x3318 Disconnected during transfer (local abort)
  • 0x3319 Illegal parameter coding (e.g. SFF coding error)

Error Class 34
Disconnect cause from the network according to ETS 300102-1/Q.931. In the field ‘xx’ the cause value received within a cause information element (octet 4) from the network is indicated.

  • 0x3481 Unallocated (unassigned) number
  • 0x3482 No route to specified transit network
  • 0x3483 No route to destination
  • 0x3486 Channel unacceptable
  • 0x3487 Call awarded and being delivered in an established channel
  • 0x3490 Normal call clearing
  • 0x3491 User busy
  • 0x3492 No user responding
  • 0x3493 No answer from user (user alerted)
  • 0x3495 Call rejected
  • 0x3496 Number changed
  • 0x349a Non-selected user clearing
  • 0x349b Destination out of order
  • 0x349c Invalid number format
  • 0x349d Facility rejected
  • 0x349e Response to STATUS ENQUIRY
  • 0x349f Normal, unspecified
  • 0x34a2 No circuit / channel available
  • 0x34a6 Network out of order
  • 0x34a9 Temporary failure
  • 0x34aa Switching equipment congestion
  • 0x34ab Access information discarded
  • 0x34ac Requested circuit / channel not available
  • 0x34af Resources unavailable, unspecified
  • 0x34b1 Quality of service unavailable
  • 0x34b2 Requested facility not subscribed
  • 0x34b9 Bearer capability not authorized
  • 0x34ba Bearer capability not presently available
  • 0x34bf Service or option not available, unspecified
  • 0x34c1 Bearer capability not implemented
  • 0x34c2 Channel type not implemented
  • 0x34c5 Requested facility not implemented
  • 0x34c6 Only restricted digital information bearer capability is available
  • 0x34cf Service or option not implemented, unspecified
  • 0x34d1 Invalid call reference value
  • 0x34d2 Identified channel does not exist
  • 0x34d3 A suspended call exists, but this call identity does not
  • 0x34d4 Call identity in use
  • 0x34d5 No call suspended
  • 0x34d6 Call having the requested call identity has been cleared
  • 0x34d8 Incompatible destination
  • 0x34db Invalid transit network selection
  • 0x34df Invalid message, unspecified
  • 0x34e0 Mandatory information element is missing
  • 0x34e1 Message type non-existent or not implemented
  • 0x34e2 Message not compatible with call state or message type non-existent or not implemented
  • 0x34e3 Information element non-existent or not implemented
  • 0x34e4 Invalid information element contents
  • 0x34e5 Message not compatible with call state
  • 0x34e6 Recovery on timer expiry
  • 0x34ef Protocol error, unspecified
  • 0x34ff Interworking, unspecified

דאָקומענטן / רעסאָורסעס

PDF thumbnailCAPI Software System
Owner's Manual · CAPI Software System, Software System

רעפערענצן

פרעגן אַ קשיא

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

פרעגן אַ קשיא

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.