הקדמה
This manual provides detailed instructions for the safe and effective operation of your Elitech DIT-220 Laser Temperature Gun. This non-contact digital infrared thermometer is designed for measuring surface temperatures across a wide range of applications, including cooking, HVAC, automotive, and various DIY projects. It offers instant, accurate readings with adjustable emissivity and a clear laser targeting system.
זיכערקייַט אינפֿאָרמאַציע
Please read all safety warnings and instructions carefully before using the device. Failure to follow these instructions may result in injury or damage to the device.
- לייזער זיכערקייַט: Do not look directly into the laser beam or point it at people or animals. The laser is for targeting purposes only.
- ניט-קאָנטאַקט מעזשערמאַנט: This device measures surface temperature only. It is not intended for measuring human or animal body temperature.
- ויסמיידן דירעקט קאָנטאַקט: Do not touch hot surfaces with the thermometer. Maintain a safe distance as indicated by the distance-to-spot ratio.
- ינווייראַנמענאַל טנאָים: Do not expose the device to extreme temperatures, humidity, or direct sunlight for prolonged periods.
- רייניקונג: ניצן אַ ווייך, דamp שטאָף פֿאַר רייניקונג. דו זאלסט נישט נוצן אַברייסיוו קלינערז אָדער סאָלוואַנץ.
- באַטערי האַנדלינג: זיכער מאַכן אַז די באַטעריע איז ריכטיק פּאָלאַריטעט. אַרויסנעמען די באַטעריעס אויב דער אַפּאַראַט וועט נישט ווערן גענוצט פֿאַר אַ לענגערע צייט.

Image: An infrared thermometer with a warning symbol indicating it is not for human or animal use, emphasizing that it measures surface temperatures only.
פּראָדוקט איבערview
The Elitech DIT-220 is a compact and ergonomic infrared thermometer designed for ease of use and accurate temperature measurement.

Image: The Elitech DIT-220 infrared thermometer, orange and black, shown alongside its retail packaging and two AAA batteries.
שליסל פֿעיִקייטן:
- Wide Temperature Range: -50°C to 530°C (-58°F to 986°F)
- High Accuracy: ±1.5% or ±1.5°C (±2.7°F)
- 12:1 דיסטאַנסע-צו-ספּאָט פאַרהעלטעניש
- Adjustable Emissivity (0.10-1.00)
- Fast Response Time: 0.5 seconds
- באַקקליט לקד ווייַז
- MAX/MIN/AVG Temperature Hold
- Unit Conversion (°F/°C)
- Auto Shut-off and Low Power Indication

Image: A graphic illustrating the key features of the Elitech DIT-220, including its wide temperature range, laser targeting, 12:1 distance-to-spot ratio, adjustable emissivity, fast response, backlit display, MAX/MIN/Average hold, auto shut-off, and low battery reminder.
קאַמפּאָונאַנץ:

Image: A diagram labeling the main components of the Elitech DIT-220: the LCD display, Mode Key, Trigger, and the location for 2 AAA batteries.
- LCD ווייַז: Shows temperature readings, unit, and various indicators.
- לאַזער אַפּערטור: Emits the targeting laser.
- ינפרערעד סענסאָר: Detects infrared radiation for temperature measurement.
- טריגער: אַקטיוויזירט מעסטונג און לאַזער.
- מאָדע שליסל: Cycles through different functions (MAX/MIN, Emissivity, Calibration).
- אַרויף/אַראָפּ קנעפּלעך: Adjust settings and switch units.
- באַטערי אָפּטייל: האלט 2 AAA באַטעריעס.
סעטאַפּ
ייַנמאָנטירונג פון באַטאַרייע:
The Elitech DIT-220 requires 2 AAA batteries (included). To install:
- Open the battery compartment cover located on the handle.
- אַרײַנשטעלן צוויי AAA באַטעריעס, און זיכער מאַכן אַז די פּאָלאַריטעט איז ריכטיק (+/-).
- פאַרמאַכן די באַטאַרייע אָפּטייל דעקן סיקיורלי.
Video: An instructional video demonstrating how to install the batteries and operate the Elitech DIT-220 infrared thermometer, including switching units, activating the laser, and adjusting emissivity.
אַפּערייטינג ינסטראַקשאַנז
1. מאַכט אויף / אַוועק:
- To power on, press the trigger. The device will automatically shut off after a period of inactivity to conserve battery.
2. Unit Conversion (°C/°F):
- מיטן אפאראט אנגעצונדן, דריק די "C/F" button (left button) to switch between Celsius and Fahrenheit.
3. Laser On/Off:
- Press the trigger to activate the laser for targeting.
- To turn off the laser, press the right button (light bulb icon).

Image: The Elitech DIT-220 infrared thermometer in use, with its laser targeting a surface and the digital display showing a temperature reading.
4. MAX/MIN/AVG Value:
- דרוק די "MODE" key to cycle through Maximum (MAX), Minimum (MIN), and Average (AVG) temperature readings.

Image: The Elitech DIT-220 thermometer displaying the MAX, MIN, and AVG temperature values, demonstrating its data hold capabilities.
5. Adjustable Emissivity (0.10-1.00):
Emissivity is the ability of a material to emit thermal energy. Different materials have different emissivities. Adjusting this setting ensures accurate readings for various surfaces.
- דרוק די "MODE" key until "EMS" appears on the display.
- ניצט די אַרויף/אַראָפּ קנעפּלעך צו סטרויערן די עמיסיוויטי ווערט פון 0.10 ביז 1.00.
- The default emissivity is 0.95, suitable for most common surfaces like wood, ceramic, and food.

Image: The Elitech DIT-220 thermometer demonstrating adjustable emissivity for various surfaces, showing recommended values for iron (0.70), oil (0.94), and ice (0.98).
6. Temperature Calibration (-5°C to 5°C):
If necessary, you can calibrate the thermometer for minor adjustments.
- דרוק די "MODE" key until "CAL" appears on the display.
- Use the Up/Down buttons to adjust the calibration value within the range of -5°C to 5°C.
7. Measurement Procedure:
- ריכט דעם טערמאָמעטער אויף דער ציל־איבערפֿלאַך.
- Press and hold the trigger. The laser will activate, and the temperature reading will appear on the display.
- Release the trigger to hold the reading. The "HOLD" icon will appear.
- Ensure the distance-to-spot ratio (D:S) is appropriate for accurate measurement. The DIT-220 has a 12:1 D:S ratio, meaning at 12 inches distance, it measures a 1-inch spot.

Image: The Elitech DIT-220 thermometer measuring the temperature of croissants inside an oven, demonstrating its non-contact capability for high-temperature applications.

Image: A diagram explaining the 12:1 distance-to-spot ratio, showing how the measurement spot size increases with distance from the target.
אַפּפּליקאַטיאָנס
The Elitech DIT-220 is suitable for a wide range of non-contact temperature measurement tasks:
- קוקינג: Checking grill, oven, or food surface temperatures.
- HVAC: Diagnosing heating and cooling systems.
- אויטאָמאָטיוו: Measuring engine components, tires, or brakes.
- ינדאַסטריאַל: Monitoring machinery, electrical panels, or manufacturing processes.
- היים נוצן: Checking insulation, appliance temperatures, or pool water.

Image: A collage showing the Elitech DIT-220 being used in diverse environments such as a kitchen, for HVAC measurement, electrical inspection, auto repair, and on a circuit board, highlighting its versatility.
וישאַלט
- רייניקונג די לענס: The most critical part of the thermometer is the lens. Keep it clean to ensure accurate readings. Use a soft cloth or cotton swab with water or medical alcohol. Do not use abrasive cleaners.
- רייניקונג פון די Casing: רייניקן דעם אַפּאַראַט casinג מיט אַדamp sponge or soft cloth and mild soap.
- סטאָרידזש: Store the thermometer in a dry, dust-free environment when not in use. Remove batteries if storing for extended periods.
- ויסמיידן שעדיקן: Do not drop the device or expose it to strong impacts.
טראָובלעשאָאָטינג
| פּראָבלעם | מעגלעך סיבה | לייזונג |
|---|---|---|
| קיין עקראַן/אַפּאַראַט וועט נישט זיך אָנצינדן | נידעריגע אדער טויטע באַטעריעס; אומרעכטע באַטעריע אינסטאַלאַציע. | פאַרבייַטן באַטעריעס; זיכער מאַכן די ריכטיקע פּאָלאַריטעט. |
| ומפּינקטלעך רידינגז | Dirty lens; incorrect emissivity setting; too far from target; smoke/steam interference. | Clean the lens; adjust emissivity for the target material; move closer to the target; avoid measuring through smoke/steam. |
| לייזער ניט קענטיק | Laser turned off; bright ambient light. | Press the right button to turn on the laser; use in less bright conditions if possible. |
| "LO" אדער "HI" ווערט געוויזן | טעמפּעראַטור איז אַרויס פון די מעסטבאַרע קייט. | Ensure the target temperature is within -50°C to 530°C (-58°F to 986°F). |

Image: An illustration showing that measuring through smoke or steam can lead to inaccurate temperature readings, advising to avoid such conditions.

Image: A tip for accurately measuring glass temperatures: place an opaque material on the glass surface and measure the temperature of that material.
ספּעסאַפאַקיישאַנז
| שטריך | דעטאַל |
|---|---|
| טעמפּעראַטור ראַנגע | -50°C צו 530°C (-58°F צו 986°F) |
| אַקיעראַסי | ±1.5% or ±1.5°C (±2.7°F) |
| דיסטאַנץ-צו-פונקט פאַרהעלטעניש (D:S) | 12:1 |
| עמיסיוויטי | Adjustable from 0.10 to 1.00 (default 0.95) |
| ענטפער צייט | 0.5 סעקונדעס |
| ספּעקטראַל ענטפער | 8-14 μם |
| מאַכט מקור | 2 X AAA באַטעריז (אַרייַנגערעכנט) |
| אַוטאָ שאַט-אַוועק | יא |
| ווייַז טיפּ | על-סי-די דיגיטאַל מיט באַקלייט |
| מאַטעריאַל | פּלאַסטיק |
| דימענשאַנז | 7.52 X 3.9 X 1.42 אינטשעס |
| וואָג | 5.29 אונסעס |
וואָראַנטי און שטיצן
For warranty information, technical support, or service inquiries, please contact Elitech customer service. Refer to the product packaging or the official Elitech webזייטל פֿאַר די מערסט אַקטועלע קאָנטאַקט דעטאַלן.
פאַבריקאַנט: עליטעטש
צוריקקער פּאָליטיק: 30-day refund/replacement (as per Amazon's buybox winner information).