ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer

ינסטראַקשאַנז מאַנואַל

הקדמה

This manual provides detailed instructions for the proper use, setup, and maintenance of your ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer. Please read this manual thoroughly before using the device to ensure accurate readings and safe operation. This device is designed for professional and home use to measure blood pressure non-invasively.

וואָס איז אין די קעסטל

ELKO EL-430 Sphygmomanometer components and packaging

Image showing the ELKO EL-430 Sphygmomanometer packaging and its main components: the high precision gauge, BP bulb with valve, and special design cotton cuff.

Upon opening the package, verify that all components are present and undamaged. The standard package for the ELKO EL-430 includes:

שליסל פֿעיִקייטן

ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer

Image of the ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer, showing the large clock-face gauge, the black cotton cuff, and the inflation bulb.

סעטאַפּ

Before taking a measurement, ensure the device is properly assembled and positioned. The EL-430 is a clock/desk type unit, designed for stable placement during use.

  1. אָפּלייגן קאַמפּאָונאַנץ: Carefully remove the sphygmomanometer, cuff, and inflation bulb from the packaging.
  2. Connect Cuff and Bulb: Ensure the cuff and inflation bulb are securely connected to the gauge via their respective tubes. The dual-tube bladder should be correctly attached.
  3. שטעלן די מיטל: Place the main gauge unit on a stable, flat surface, such as a desk or table, at approximately heart level. The integrated basket can be used to keep the cuff and bulb organized.
  4. פּאַציענט צוגרייטונג: The patient should be seated comfortably with their arm resting on a flat surface, palm facing upwards. Ensure the arm is relaxed and at heart level. Avoid talking or moving during the measurement.

Operating Instructions: Measurement Procedures

Blood Pressure Measurement Procedures

Image illustrating the four key steps for blood pressure measurement: stethoscope placement, cuff inflation, listening for Korotkoff sounds, and controlled deflation.

גיי די סטעפּס פֿאַר פּינטלעך מעזשערמאַנט פון בלוט דרוק:

  1. Cuff Placement and Stethoscope Positioning: Wrap the cuff firmly around the upper arm, ensuring it is snug but not too tight. The lower edge of the cuff should be about 1 inch (2-3 cm) above the elbow joint. Place the stethoscope head over the main artery (brachial artery), which is typically found on the inner side of the arm, underneath the artery mark of the cuff.
  2. ינפלאַציע: With the air release valve completely closed, press the inflation bulb repeatedly and continue pumping until the gauge reads a value 20-30 mmHg above your normal systolic blood pressure. If you do not know your normal systolic pressure, inflate to approximately 180-200 mmHg.
  3. Listening and Recording Systolic Pressure: Slowly open the air release valve to deflate the cuff at a rate of 2-3 mmHg per second. Listen carefully through the stethoscope. The first distinct, rhythmic sound you hear (Korotkoff sound) indicates the systolic pressure (the upper number). Note the reading on the gauge at this exact moment.
  4. Listening and Recording Diastolic Pressure: Continue to slowly deflate the cuff. The point at which the Korotkoff sounds completely disappear indicates the דיאַסטאָליק דרוק (the lower number). Note this reading on the gauge. If the sounds become muffled but do not disappear, the muffled sound point can be considered the diastolic pressure.

פארשטאנד פון בלוט דרוק רידינגז

Blood Pressure Chart and Reading Precautions

Image displaying a blood pressure chart categorizing readings (Normal, Elevated, High Blood Pressure Stages 1 & 2, Hypertensive Crisis) and a list of conditions under which a reading should not be attempted.

Refer to the chart below for general blood pressure categories. Consult a healthcare professional for interpretation of your readings and personalized advice.

Blood Pressure Chart (mmHg)
בלוט דרוק קאַטעגאָריעSystolic (upper number)Diastolic (lower number)
נאָרמאַלווייניקער ווי 120ווייניקער ווי 80
עלעוואַטעד120 - 129ווייניקער ווי 80
הויך בלוט דרוק (כייפּערטענשאַן) סtage 1130 - 13980 - 89
הויך בלוט דרוק (כייפּערטענשאַן) סtage 2140 אָדער העכער90 אָדער העכער
Hypertensive Crisis (consult your doctor immediately)העכער ווי 180העכער ווי 120

DO NOT ATTEMPT A READING...

  1. Within 1 hour of food intake.
  2. Immediately after a tea, coffee, or a smoke.
  3. Within 20 minutes of taking a bath.
  4. While talking or moving your hand/fingers.
  5. When climate is very cold.
  6. When bladder is full or you feel like discharging urine.

וישאַלט און זאָרג

Proper maintenance ensures the longevity and accuracy of your sphygmomanometer.

טראָובלעשאָאָטינג

If you encounter issues with your ELKO EL-430, refer to the following common problems and solutions:

ספּעסאַפאַקיישאַנז

באַשרייַבונגדעטאַל
מאָדעל נומערEL-430
ווייַז טיפּאַנאַלאָג
מעאַסורעמענט ראַנגע0 - 300 mmHg
אַקיעראַסי+/- 3 מ״מ הג
מאַנזשעט טיפּLarge Cotton Cuff with Velcro Fasteners
אַרייַנגערעכנט קאַמפּאָונאַנץCuff, Gauge, Inflation Bulb with Valve
פּונקט וואָג600 ג
פּראָדוקט דימענשאַנז (L x W x H)14L x 14W x 18Th Centimeters
פאַבריקאַנטAnita Industries
לאַנד פון אָריגיןאינדיע
ערשטער דאַטע בנימצא12 פעברואר 2024

וואָראַנטי און שטיצן

For warranty information, technical support, or service inquiries regarding your ELKO EL-430 Sphygmomanometer, please contact the manufacturer directly.

פאַבריקאַנט קאָנטאַקט אינפֿאָרמאַציע:
Anita Industries
New Delhi, India
בליצפּאָסט: info@elkoindia.com
טעלעפאָנירן: +91 9911129201

Please have your model number (EL-430) and date of purchase available when contacting support.

פֿאַרבונדענע דאָקומענטן - EL-430

Preview ELKO RS16 טעלעוויזיע/סאט/ר סאקעט סוף פון לעבן אינסטרוקציעס און באַזייַטיקונג גייד
אן אויספירלעכע אנווייזונג פארן ענד-פון-לעבן באהאנדלונג און באַזייַטיקונג פון די ELKO RS16 TV/SAT/R סאָקעט, אַרייַנגערעכנט פּראָדוקט דעטאַילס, קאָמפּאָנענט אינפֿאָרמאַציע, און ריסייקאַלאַביליטי פּאָטענציעל לויט WEEE דירעקטיוו.
Preview עלקאָ קלוגע ראַדיאַטאָר טערמאָסטאַט מיטל באַניצער גייד
א פולשטענדיגע באַניצער גייד פֿאַר די ELKO סמאַרט ראַדיאַטאָר טערמאָסטאַט, וואָס דעקט קאַמישאַנינג, סעטאַפּ, קאָנפיגוראַציע, באַניץ, טראָובלעשווטינג, און טעכנישע ספּעסיפיקאַציעס. לערנט ווי צו פאַרבינדן, קאָנטראָלירן, און אָטאַמייט דיין הייצונג סיסטעם פֿאַר קאָמפאָרט און ענערגיע עפעקטיווקייט.
Preview ELKO Schuko Socket Outlet with USB 3.0 A Charger - Installation and User Guide
Comprehensive guide for the ELKO Schuko socket outlet featuring dual USB 3.0 A charging ports (Type A and Type C). Includes essential safety warnings, detailed technical specifications, installation steps, and usage instructions for electrical professionals and end-users.
Preview ELKO Plus / ELKO RS16 DCL וואנט אַוטלעט ינסטאַלירונג אינסטרוקציעס
א פולשטענדיגע אינסטאַלאַציע גייד פֿאַר ELKO Plus און ELKO RS16 DCL וואַנט אַוטלעץ. כולל קריטישע זיכערהייט וואָרענונגען, שריט-פֿאַר-שריט מאָנטירונג פּראָצעדורן, דעקל דיסמאַנטלינג, פּלאַג קאַנעקשאַן, טעכנישע ספּעסיפיקאַציעס, און ריכטיק באַזייַטיקונג אינפֿאָרמאַציע. וויכטיק פֿאַר קוואַליפֿיצירטע עלעקטריקער.
Preview ELKO קלוגע ראַדיאַטאָר טערמאָסטאַט באַניצער גייד - ינסטאַלירונג, קאָנפיגוראַציע און אָפּעראַציע
א פולשטענדיגע באַניצער גייד פֿאַר די ELKO סמאַרט ראַדיאַטאָר טערמאָסטאַט (EKO09765), וואָס דעקט ינסטאַלירונג, פּערינג, קאָנפיגוראַציע, טעגלעך נוצן, סקעדזשולינג, אָטאַמאַציע, טראָובלעשווטינג, און טעכנישע ספּעסיפיקאַציעס.
Preview עלקאָ סמאַרט ראַדיאַטאָרטערמאָסטאַט ברוקערהאַנדבאָאָק
דעטאַילעד באַניצער האַנטבאָק פֿאַר עלקאָ סמאַרט ראַדיאַטאָרטערמאָסטאַט, ווי דעקער אַפּערייטינג, נוצן, פּאַרינג, אַוטאָמאַטיאָן, טעות און טעכניש ספּעסאַפאַקיישאַנז פֿאַר אָפּטימאַל היים אַפּערייטינג סיסטעם.