Reznor UDXC-150 150,000 BTU LP Gas Unit Heater Instruction Manual

מאָדעל: UDXC-150 | בראַנד: רעזנאר

וויכטיק סאַפעטי אינפֿאָרמאַציע

Read and understand all instructions before installing, operating, or servicing this unit heater. Failure to follow these instructions could result in property damage, personal injury, or death.

  • גאַז זיכערקייַט: This unit uses LP (Liquid Propane) gas. Ensure all gas connections are properly sealed and tested for leaks. Installation must comply with local codes and national standards.
  • עלעקטריקאַל זיכערקייַט: Ensure the unit is properly grounded and connected to the correct power supply as specified. Disconnect power before servicing.
  • ווענטילאַטיאָן: Proper venting is crucial to prevent carbon monoxide poisoning. Ensure the exhaust system is correctly installed and maintained.
  • ייַנמאָנטירונג: Only qualified personnel should install and service this appliance. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death.
  • פאָרלייג 65 ווארענונג: דער פּראָדוקט קענען ויסשטעלן איר צו קעמיקאַלז אַרייַנגערעכנט בלייַ, וואָס איז באַוווסט צו די שטאַט פון קאַליפאָרניאַ צו פאַרשאַפן ראַק און געבורט חסרונות אָדער אנדערע רעפּראָדוקטיווע שאָדן. פֿאַר מער אינפֿאָרמאַציע גיין צו www.P65Warnings.ca.gov.

פּראָדוקט איבערview

The Reznor UDXC-150 is a 150,000 BTU LP Gas Unit Heater designed for commercial and industrial applications such as garages, workshops, warehouses, and factories. It features a forced-air design with a low static propeller fan for efficient heat distribution.

Reznor UDXC-150 LP Gas Unit Heater

בילד: פראָנט view of the Reznor UDXC-150 LP Gas Unit Heater.

שליסל פֿעיִקייטן:

  • Propane Compatibility: Designed for LP gas, suitable for various indoor commercial or industrial settings.
  • הויך פאָרשטעלונג: 150,000 BTU output with two heating levels (low fire 87,150 BTU / high fire 124,500 BTU) and 83% thermal efficiency.
  • מאַונטינג ווערסאַטילאַטי: Threaded-nut retainers at four suspension points allow for ceiling or wall mounting (mounting hardware sold separately).
  • דוראַבאַל קאַנסטראַקשאַן: Features a TCORE2 titanium-stabilized aluminized steel heat exchanger.
  • אַוואַנסירטע קאָנטראָלס: Patented single-burner combustion, integrated circuit board with display, built-in disconnect, and current status LED for diagnostics.

טעכניש ספּעסאַפאַקיישאַנז

שטריךבאַשרייַבונג
סאָרטReznor (1HVAC)
מאָדעל נומערUDXC-150 | 1043187R
היץ רעזולטאַט150,000 בריטישע טערמישע איינהייטן (BTU)
ברענוואַרג טיפּLiquid Propane (LP Gas) - Convertible from Natural Gas
טערמאַל עפיקאַסי83%
נומער פון ספּידז2 (Low Fire: 87,150 BTU / High Fire: 124,500 BTU)
Ampעראַגע11 Amps
פּראָדוקט דימענשאַנז48.88"ד רענטגענ 41"וו רענטגענ 34.13"ה
מאַונטינג טיפּCeiling Mount / Wall Mount (Mounting hardware sold separately)
דרינענדיק / דרויסנדיק באַניץדרינענדיק
ספּעציעלע שטריךשנעל באַהיצונג
היץ עקסטשאַנגערTCORE2 Titanium-Stabilized Aluminized Steel
Reznor UDXC-150 Unit Heater Dimensions

Image: Diagram showing the dimensions of the Reznor UDXC-150 unit heater.

סעטאַפּ און ינסטאַלירונג

Proper installation is critical for the safe and efficient operation of your Reznor UDXC-150 unit heater. Consult a qualified HVAC professional for installation to ensure compliance with all local and national codes.

פאַר-ינסטאַלירונג טשעקס:

  • Verify that the unit's BTU output is appropriate for the space to be heated.
  • Ensure adequate clearance from combustible materials as specified in the installation manual.
  • Confirm that the gas supply (LP) and electrical supply meet the unit's requirements.
  • If converting from natural gas to LP, ensure the provided LP conversion kit is correctly installed by a qualified technician.

מאָונטינג:

The UDXC-150 can be ceiling-mounted or wall-mounted using appropriate brackets (sold separately). The unit includes threaded-nut retainers at four suspension points for secure attachment.

Reznor UDXC-150 Unit Heater Ceiling Mounted

Image: Reznor UDXC-150 unit heater installed and suspended from a ceiling, highlighting its mounting options.

Gas and Electrical Connections:

  • Connect the LP gas supply line to the unit, ensuring all connections are tight and leak-free.
  • Wire the unit to the electrical supply according to the wiring diagram in the full installation manual. This includes connections for the fan, combustion blower, and integrated circuit board.

ווענטינג:

The unit is compatible with Category I double-wall B-vent pipe for vertical or horizontal venting. Ensure the vent pipe is properly sized, installed, and sealed to safely exhaust combustion byproducts.

אַפּערייטינג ינסטראַקשאַנז

Once installed and all connections are verified, follow these steps to operate your Reznor UDXC-150 unit heater:

  1. מאַכט אויף: Ensure the main electrical supply to the unit is switched on.
  2. גאַז צושטעלן: Open the manual gas shut-off valve to allow LP gas to flow to the unit.
  3. טערמאַסטאַט סעטטינגס: Set the thermostat to your desired temperature. The unit will automatically cycle on and off to maintain this temperature.
  4. Heat Output Selection: The UDXC-150 offers two heat output levels. Refer to the full manual for instructions on how to select between low fire (87,150 BTU) for milder conditions and high fire (124,500 BTU) for colder periods.
  5. ערשט סטאַרטאַפּ: Upon initial startup or after a prolonged shutdown, it may take a few minutes for the gas lines to purge air, and the unit may attempt ignition multiple times before successfully lighting.
  6. שאַטדאַון: To turn off the unit, lower the thermostat setting below the ambient temperature or switch off the main electrical supply. For extended shutdowns, close the manual gas shut-off valve.
Reznor UDXC-150 Heating Flexibility

Image: Graphic illustrating the heating flexibility of the Reznor UDXC-150 with its dual BTU output for varying temperatures.

וישאַלט

Regular maintenance ensures the longevity and efficient operation of your unit heater. Perform the following checks periodically:

  • יערלעך דורכקוק: Have a qualified service technician inspect the unit annually, preferably before the heating season.
  • ריינקייַט: Keep the area around the heater clear of debris and obstructions. Ensure the air intake and discharge grilles are clean.
  • ווענטילאַציע סיסטעם קאָנטראָל: Inspect the vent pipe for any signs of corrosion, leaks, or blockages.
  • קאָמפּאָנענט דורכקוק: Check electrical connections for tightness and signs of wear. Inspect the fan and motor for proper operation and lubrication if required.

טראָובלעשאָאָטינג

If your Reznor UDXC-150 unit heater is not operating correctly, refer to the following common issues before contacting a service technician:

  • No Heat/Unit Not Starting:
    • Check if the electrical power supply is on.
    • ענשור אַז די גאַז צושטעלן וואַלוו איז אָפן.
    • Verify the thermostat is set above the ambient temperature.
    • Check the unit's integrated circuit board display and status LED for diagnostic codes. Refer to the full manual for code interpretations.
  • ניט גענוגיק היץ:
    • Confirm the unit is operating on the high fire setting if maximum heat is desired.
    • Ensure no obstructions are blocking the air intake or discharge.
    • Check for proper ventilation and insulation of the heated space.
  • ומגעוויינטלעך נויזיז אָדער אָודערז:
    • Immediately shut off the gas supply and electrical power.
    • Do not attempt to operate the unit. Contact a qualified service technician.

For detailed troubleshooting steps and error code explanations, consult the complete installation and operation manual provided with your unit.

וואָראַנטי און שטיצן

This Reznor UDXC-150 unit heater is backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or contact Reznor customer support.

If you require technical assistance, parts, or service, please contact the authorized dealer or service center where you purchased the unit. Ensure you have your model number (UDXC-150) and serial number available when contacting support.

For general inquiries or to locate an authorized service provider, visit the official Reznor website or contact 1HVAC, the brand associated with this product.

פֿאַרבונדענע דאָקומענטן - UDXC-150

Preview רעזנאָר סופיט סאַספּענשאַן קיט ינסטאַלירונג גייד פֿאַר עלעקטרישע און גאַז-פייערד אַפּאַראַט כיטערס
אינסטאַלאַציע אינסטרוקציעס און קאָמפּאָנענט דעטאַילס פֿאַר די Reznor CK22 סופיט סאַספּענשאַן קיט, קאָמפּאַטיבל מיט EHU עלעקטרישע און UDXC, UDX, UDZ גאַז-פייערד יוניט כיטערס. לערנט ווי זיכער צו מאָנטירן דיין Reznor כיטער.
Preview Reznor Gas Conversion Kit Installation for Gas-Fired Unit Heaters
This document provides installation instructions for Reznor gas conversion kits for various gas-fired unit heater models, including UBX, UBXC, UBZ, UDX, UDXC, UDZ, UDAP, UDAS, UDBP, and UDBS. It details component selection, safety precautions, and installation steps for converting between natural gas and propane, as well as for high-elevation installations.
Preview Reznor Relay Kit Installation Guide for Multiple Unit Control (CL31/CL32)
Comprehensive installation guide for Reznor CL31 and CL32 relay kits, enabling multiple unit control for various Reznor electric and gas-fired heaters. Includes component lists, detailed installation steps, and wiring specifications.
Preview רעזנאָר סופיט סאַספּענשאַן קיט ינסטאַלירונג פֿאַר עלעקטרישע און גאַז-פייערד אַפּאַראַט כיטערס (אָפּציע CK22)
אינסטאַלאַציע גייד פֿאַר די Reznor CK22 דעקע סאַספּענשאַן קיט, דיזיינד פֿאַר EHU, UDX, UDXC, און UDZ עלעקטרישע און גאַז-געפֿײַערטע יוניט כיטערס. כולל קיט קאָמפּאָנענטן און אינסטאַלאַציע סטעפּס.
Preview רעזנאָר ווערטיקאַל לאָוווער קיט ינסטאַלירונג גייד פֿאַר גאַז-פייערד יוניט כיטערס (OPT-CD1)
אינסטאַלאַציע אינסטרוקציעס פֿאַר די Reznor OPT-CD1 ווערטיקאַל לאָוווער קיט, דיזיינד פֿאַר גאַז-געפֿײַערטע אַפּאַראַט כיטערס (מאָדעלן UBX, UBXC, UBZ, UDX, UDXC, UDZ, UEZ). כולל קאָמפּאָנענט רשימה און שריט-פֿאַר-שריט אַסעמבלי גייד.
Preview Reznor UBXC/UDXC Gas-Fired Unit Heater Replacement Parts Manual
This manual provides detailed replacement parts information for Reznor UBXC and UDXC series gas-fired unit heaters. It includes sections on serial number decoding, electrical components, fan and motor assemblies, blower assemblies, cabinet components, heat exchanger and burner assemblies, venter and flue wrapper components, and various accessories and options.