AEM 30-0300

AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge User Manual

1. הקדמה

This manual provides comprehensive instructions for the installation, operation, and maintenance of the AEM 30-0300 X-Series Wideband UEGO Air/Fuel Ratio (AFR) Sensor Controller Gauge. The AEM X-Series Wideband UEGO gauge utilizes advanced X-Digital technology to deliver fast and accurate air/fuel ratio readings, crucial for optimal engine tuning and monitoring.

2. זיכערקייַט אינפֿאָרמאַציע

WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.

Always ensure proper ventilation when working on vehicles. Disconnect the vehicle's battery before performing any electrical work. Incorrect installation or use can lead to vehicle damage or personal injury. If you are unsure about any installation steps, consult a qualified automotive technician.

3. וואָס איז אין דער קעסטל

The AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge package includes the following components:

Contents of AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge kit

Image 3.1: All components included with the AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge. This includes the gauge, wideband sensor, various wiring harnesses, and mounting accessories.

4. שליסל פֿעיִקייטן

The AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge offers several advanced features:

5. סעטאַפּ און ייַנמאָנטירונג

Proper installation is critical for the accurate and reliable operation of your AEM X-Series Wideband UEGO Gauge. It is recommended that installation be performed by a qualified professional.

5.1 ינסטאַלירונג פון סענסאָרס

The wideband UEGO sensor must be installed in the exhaust system. For optimal performance, install the sensor at least 18 inches downstream from the exhaust port, before any catalytic converters. Ensure the sensor bung is welded securely and the sensor is oriented to prevent condensation buildup.

5.2 Gauge Mounting

Mount the gauge in a location that is easily visible to the driver and protected from direct moisture and extreme heat. The gauge fits into a standard 52mm (2-1/16 inch) opening.

זייַט view of AEM 30-0300 gauge showing mounting studs

בילד 5.1: זייט view of the AEM 30-0300 gauge, illustrating its compact design and the rear mounting studs for secure installation into a dashboard or gauge pod.

5.3 וויירינג קאַנעקשאַנז

The gauge requires power, ground, and connections to the wideband sensor. Additionally, there are output wires for data logging and feedback control. Refer to the official AEM user guide PDF for detailed wiring diagrams specific to your application.

AEM 30-0300 wideband sensor and wiring harnesses

Image 5.2: The wideband sensor and associated wiring harnesses. Proper connection of these components is essential for accurate AFR readings and data output.

For detailed wiring diagrams and installation steps, please refer to the official AEM User Guide PDF linked in Section 9.

6. אַפּערייטינג ינסטרוקטיאָנס

Once properly installed and powered, the AEM X-Series Wideband UEGO Gauge will display the current Air/Fuel Ratio (AFR) or Lambda value. The gauge automatically calibrates the sensor upon startup.

6.1 לייענען דעם דיספלעי

The large seven-segment display shows the numerical AFR value. The outer LED sweep provides a quick visual reference of the AFR range. The gauge typically displays AFR values from 8:1 (rich) to 20:1 (lean).

Close-up of AEM 30-0300 gauge display showing AFR reading

בילד 6.1: נאָענט־אַרויף view of the AEM 30-0300 gauge display, showing a typical AFR reading and the surrounding LED sweep for quick visual interpretation.

6.2 Mode and Select Buttons

The gauge features 'MODE' and 'SEL' (Select) buttons, typically located on the front or side of the unit. These buttons allow you to cycle through display modes (e.g., AFR, Lambda) or perform specific functions as outlined in the detailed user manual.

7. וישאַלט

The AEM X-Series Wideband UEGO Gauge and sensor are designed for durability, but proper maintenance ensures longevity and accuracy.

8. טראָובלעשאָאָטינג

If you encounter issues with your AEM X-Series Wideband UEGO Gauge, consider the following common troubleshooting steps:

For more detailed troubleshooting guides and error codes, refer to the complete AEM User Guide PDF.

9. ספּעסאַפאַקיישאַנז

באַשרייַבונגווערט
מאָדעל נומער30-0300
מאָס טיפּWideband UEGO AFR Sensor Controller Gauge
טעכנאָלאָגיעX-Digital
ווייַזDigital 7-segment with LED sweep
רעזולטאַט סיגנאַלז0-5v Analog, RS232 Serial Port, AEMnet (CANbus)
מאָס דיאַמעטער52mm (2-1/16 inch)
פּונקט וואָג0.01 ounces (Controller/Gauge only)
פאַבריקאַנטAEM

10. וואָראַנטי און שטיצן

For warranty information, please refer to the documentation provided with your product or visit the official AEM website. AEM provides technical support for its products. If you require assistance with installation, operation, or troubleshooting beyond the scope of this manual, please contact AEM customer service directly.

11. נאָך רעסאָורסעס

For the most detailed and up-to-date installation instructions, wiring diagrams, and advanced features, please download the official AEM User Guide PDF:

דאַונלאָודן אפיציעלע באַניצער גייד (PDF)

פֿאַרבונדענע דאָקומענטן - 30-0300

Preview AEM 30-4110 Gauge-Type UEGO Controller Installation Instructions
Detailed installation instructions for the AEM 30-4110 Gauge-Type UEGO Controller. Learn how to install, wire, and calibrate this advanced air/fuel ratio monitoring system for performance vehicles.
Preview AEM EMS 30-6300 Installation Instructions for Mitsubishi Eclipse, Talon, Laser, Galant VR4
Comprehensive installation guide for the AEM Engine Management System (EMS) P/N 30-6300, designed for 1990-1994 Mitsubishi Eclipse Turbo, Talon Tsi, Dodge/Eagle Talon Tsi, Mitsubishi Eclipse RS, and Mitsubishi Galant VR4. Covers software installation, ECU removal/installation, calibration, tuning, troubleshooting, sensor configuration, wiring, and pinout diagrams.
Preview AEM 30-3511 Infinity PnP Adapter Harness Installation Manual for 2003-2005 Mitsubishi EVO 8
Comprehensive installation manual for the AEM 30-3511 Infinity Plug and Play Adapter Harness for 2003-2005 Mitsubishi EVO 8 models. Covers overview, kit contents, options, important application notes, installation steps, setup wizard, and pinout information.
Preview AEM EMS P/N 30-6320 Installation Guide for Mitsubishi Lancer Evolution IX & VIII
Comprehensive installation instructions and technical details for the AEM EMS P/N 30-6320 Plug and Play Engine Management System for Mitsubishi Lancer Evolution IX and VIII models. Includes setup, tuning notes, wiring diagrams, pinouts, and warranty information.
Preview How to Convert AEM TestPro REMOTE to MAIN Unit
Step-by-step guide from AEM on how to temporarily convert a TestPro REMOTE unit to a MAIN unit to increase productivity for specific network testing tasks.
Preview AEM 21-8128DC Installation Instructions for 2015 Ford F150 EcoBoost
Detailed installation guide for the AEM 21-8128DC performance air intake system for 2015 Ford F150 EcoBoost 2.7L and 3.5L Turbo models. Includes parts list and step-by-step instructions.