True TRUE988284

True 988284 Temperature Control Kit 077B6856 Instruction Manual

Model: TRUE988284

1. פּראָדוקט איבערview

The True 988284 Temperature Control Kit 077B6856 is a genuine Original Equipment Manufacturer (OEM) replacement part designed for True Refrigeration units. This kit ensures the proper regulation of temperature within your commercial refrigeration equipment, maintaining optimal operating conditions for safety, reliability, and performance.

True 988284 Temperature Control Kit with dial and capillary tube

בילד 1.1: איבערview of the True 988284 Temperature Control Kit, showing the control unit, dial, and capillary tube.

שליסל פֿעיִקייטן:

2. זיכערקייַט אינפֿאָרמאַציע

וויכטיק: Read all instructions carefully before installation or operation. Failure to follow these instructions may result in property damage, personal injury, or death.

3. פּעקל אינהאַלט

באַשטעטיקן אַז אַלע קאָמפּאָנענטן זענען פאַראַן און נישט געשעדיגט ווען איר עפֿנט דעם פּאַקעט.

Components of the True 988284 Temperature Control Kit including control unit, dial, screws, and connectors

Image 3.1: Contents of the True 988284 Temperature Control Kit, typically including the control module, temperature dial, mounting screws, and electrical connectors.

4. ינסטאַלירונג אינסטרוקציעס

This section provides general guidance for replacing a temperature control kit. Specific installation steps may vary depending on your True Refrigeration model. Refer to your unit's service manual for detailed, model-specific instructions.

  1. דיסקאַנעקט מאַכט: Locate the main power supply to the refrigeration unit and disconnect it. Verify that power is off using a voltagE tester.
  2. Access Control Area: Depending on your unit, you may need to remove access panels or grilles to reach the existing temperature control.
  3. דאָקומענט וויירינג: Before disconnecting any wires, take clear photos or make a diagram of the existing wiring connections to the old temperature control. Note the position of the capillary tube sensor.
  4. אַראָפּנעמען אַלטע קאָנטראָל:
    • Carefully disconnect the electrical wires from the old control.
    • Unmount the old control from its housing.
    • Gently remove the capillary tube sensor from its sensing location (e.g., evaporator coil, air return).
  5. אינסטאַלירן נייע קאָנטראָל:
    • Insert the new capillary tube sensor into the exact same sensing location as the old one. Ensure it is securely positioned for accurate temperature readings. Avoid kinking or damaging the tube.
    • Mount the new temperature control module in the same position as the old one using the provided screws.
    • Connect the electrical wires to the new control according to your documented wiring diagram. Ensure connections are secure.
  6. ריאַסעמבאַל: פֿאַרבײַטן אַלע צוטריט פּאַנעלן אָדער גרילן וואָס זענען אַוועקגענומען געוואָרן.
  7. ומקערן מאַכט: Reconnect the main power supply to the refrigeration unit.
  8. טעסט אָפּעראַציע: Allow the unit to run for a period and monitor the temperature to ensure proper operation and temperature regulation. Adjust the dial as needed.

באַמערקונג: If you are unsure about any step, consult a qualified refrigeration technician.

5. אַפּערייטינג ינסטרוקטיאָנס

The temperature control kit features a rotary dial for adjusting the desired temperature within your True Refrigeration unit.

6. וישאַלט

The True 988284 Temperature Control Kit is designed for durability and reliability. Regular maintenance of the overall refrigeration unit is crucial for its longevity and efficient operation.

7. טראָובלעשאָאָטינג

If your refrigeration unit is experiencing temperature issues after installing this kit, consider the following common troubleshooting steps:

פּראָבלעםמעגלעך סיבהלייזונג
Unit not cooling or too warm
  • Temperature dial set too high (warmer)
  • Capillary tube not properly seated or damaged
  • פרייַ עלעקטריקאַל קשר
  • Other refrigeration system issues (e.g., low refrigerant, dirty condenser)
  • Adjust dial to a colder setting.
  • Verify capillary tube placement and condition.
  • Check and secure all wiring connections (with power disconnected).
  • Consult a qualified technician for system diagnosis.
Unit freezing contents or too cold
  • Temperature dial set too low (colder)
  • Capillary tube sensing incorrect temperature (e.g., too close to evaporator)
  • קאָנטראָל אַפּאַראַט מאַלפאַנגקשאַן
  • Adjust dial to a warmer setting.
  • Ensure capillary tube is correctly positioned away from direct evaporator contact if applicable.
  • If issues persist, the control unit may require replacement or further diagnosis by a technician.
טעמפּעראַטור וואַקסירט ברייט
  • Improper capillary tube placement
  • קאָנטראָל אַפּאַראַט מאַלפאַנגקשאַן
  • Refrigeration system issues
  • Verify capillary tube placement.
  • Consult a qualified technician for diagnosis.

ווארענונג: Do not attempt repairs beyond your technical capabilities. Always prioritize safety and consult a professional for complex issues.

8. ספּעסאַפאַקיישאַנז

שטריךדעטאַל
סאָרטאמת
מאָדעל נומערTRUE988284
פּראָדוקט דימענשאַנז6 X 6 X 4 אינטשעס
פּונקט וואָג4.8 אונסעס
אָפּעראַציע מאָדעאָטאַמאַטיק
קאָנטאַקט טיפּנאָרמאַללי עפֿן
קאַנעקטער טיפּשרויף טערמינאַלס
טערמינאַלשרויף
קרייַז טיפּ1-וועג
מאַונטינג טיפּייבערפלאַך בארג
אַקטואַטאָר טיפּדרוק קנעפּל
קאָנטאַקט מאַטעריאַלקופּער, מעשינג
ערשטער דאַטע בנימצא15 יוני 2011

9. וואָראַנטי און שטיצן

As a genuine OEM part, this True 988284 Temperature Control Kit is manufactured to high standards. For specific warranty information, please refer to the documentation provided with your original True Refrigeration unit or contact True Refrigeration directly.

קונה שטיצן:

For technical assistance, troubleshooting beyond this manual, or to inquire about warranty claims, please contact True Refrigeration customer support or an authorized service provider.

פֿאַרבונדענע דאָקומענטן - TRUE988284

Preview אמתע קאָממערזיעללע כּוהלטעקניק: אַלגעמיינער רעגעלונגסלייטפאַדן
פאַרהאַנדלונג פון טעמפּעראַטור רעגולאַטיאָנס אין אמת קאַמערשאַל קיילים און געפרייערז. דערהייַנטיקונגען פֿאַר מעטשאַניקאַל און עלעקטראָניש סטעuerונגען מיט ספּעציעלע מאָדעלס אינפֿאָרמאַציע.
Preview TRUE מאַנופאַקטורינג ינסטאַלירונג מאַנואַל שנעל אָנהייב גייד
דאס דאקומענט גיט וויכטיגע אינסטאַלאַציע, אָפּעראַציע און וישאַלט גיידליינז פֿאַר TRUE Manufacturing קאמערציעלע קיל און הייצונג אַפּפּליאַנסעס. עס כולל זיכערהייט וואָרענונגען, ספּעסיפיקאַציעס, סעטאַפּ פּראָוסידזשערז און זאָרג אינסטרוקציעס.
Preview טרו TH מאָדעלן העאַטעד קאַבינעטן ינסטאַלירונג מאַנואַל
א פולשטענדיגע אינסטאַלאַציע, אָפּעראַציע און וישאַלט פירער פֿאַר True TH מאָדעלס באַהייצטע קאַבינעטן. דעקט זיכערהייט, עלעקטרישע, סעטאַפּ, זאָרג און וואָראַנטי אינפֿאָרמאַציע פֿון True Manufacturing Co., Inc.
Preview True T-23DF-HC קאמערציעלע פרידזשידער/פריזער אינסטאַלירונג און אָפּעראַציע מאַנואַל
א פולשטענדיגע אינסטאַלאַציע, אָפּעראַציע, וישאַלט, און זיכערהייט גייד פֿאַר די True T-23DF-HC צוויי-קאַמער קאמערציעלע פרידזשידער/פריזער. כולל טראָובלעשווטינג, רייניקונג אינסטרוקציעס, און וואָראַנטי אינפֿאָרמאַציע.
Preview טרו CVM סעריע אינסטאַלאַציע מאַנואַל
א פולשטענדיגע אינסטאַלאַציע, אָפּעראַציע און וישאַלט מאַנואַל פֿאַר True CVM סעריע קילער וניץ. דעקט זיכערהייט מיטלען, עלעקטרישע רעקווייערמענץ, אינסטאַלאַציע פּראָצעדורן, לעוועלינג, סילינג, פּאָליצע מאַונטינג און אַלגעמיינע וישאַלט.
Preview מאַנועל ד'ינסטאַלאַטיאָן און דעמאַרראַגע ראַפיד אמת
גייד גאַנץ פֿאַר די ינסטאַללאַטיאָן, די יוטאַלאַזיישאַן און די רעפריגעראַטיאָן פון קליידער און די קאַנדזשעלאַטיאָן אמת מאַנופאַקטורינג קאָו, ינק.