The Watts LF-MMV-M1-UT is a 1-inch thermostatic mixing valve designed to precisely control water temperature. It features FPT (Female Pipe Thread) union connections and allows for an adjustable temperature range from 80 degrees to 120 degrees Fahrenheit, with a flow rate capacity of 0.5 to 12 GPM. This valve utilizes a solid wax hydraulic principle thermostat to ensure dependable mixing of hot and cold fluids, providing a consistent and safe mixed water temperature. It also incorporates integral check valves and filter washers to prevent cross-flow and restrict mixed water flow if the cold water supply is compromised, enhancing safety.

Figure 1: Watts LF-MMV-M1-UT Thermostatic Mixing Valve. This image displays the brass valve body with three ports and union connections, topped by a light-colored adjustment cap.
2. זיכערקייַט אינפֿאָרמאַציע
ווארענונג: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Always follow local plumbing codes and regulations during installation and operation.
- Ensure all water supplies are shut off before installation or maintenance.
- טראָגט פּאַסיקע פּערזענלעכע שוץ-עקוויפּמענט (PPE) ווי הענטשקעס און אויג-שוץ.
- נישט איבערשטייגן דעם מאקסימום אפעראציע דרוק פון 150 PSI.
- Verify that the mixed water temperature is safe for its intended application, especially in domestic hot water systems to prevent scalding.
- Installation should be performed by a qualified professional in accordance with all applicable codes.
3. סעטאַפּ און ייַנמאָנטירונג
Proper installation is crucial for the optimal performance and safety of the thermostatic mixing valve. Refer to the diagram below for typical installation orientation.
3.1 פאַר-ינסטאַלירונג טשעקס
- Inspect the valve for any signs of damage.
- Ensure all necessary plumbing fittings and tools are available.
- Confirm the water supply lines (hot and cold) are clearly identified.
3.2 ינסטאַללאַטיאָן סטעפּס
- Shut off Water Supply: Turn off the main water supply to the area where the valve will be installed.
- Drain Lines: Open nearby faucets to drain residual water from the pipes.
- Connect Valve:
- Connect the hot water supply to the designated hot inlet (typically marked 'H' or 'HOT').
- Connect the cold water supply to the designated cold inlet (typically marked 'C' or 'COLD').
- Connect the mixed water outlet to the distribution system (typically marked 'M' or 'MIX').
The valve features FPT union connections for ease of installation and removal.
- זיכער קאַנעקשאַנז: Use appropriate pipe sealant or PTFE tape on all threaded connections to ensure a watertight seal. Tighten connections securely but do not overtighten.
- צוריקשטעלן וואַסער צושטעל: שטייטלעך צינדט אן די הויפט וואסער צושטעל און קוקט איבער פאר ליקס.
- רייניקונג לופט: Open faucets downstream to purge air from the system until water flows smoothly.
4. אַפּערייטינג ינסטרוקטיאָנס
The Watts LF-MMV-M1-UT valve is designed for automatic temperature regulation. Once installed, its primary operation involves setting the desired mixed water temperature.
4.1 טעמפּעראַטור אַדזשאַסטמאַנט
- Locate Adjustment Cap: The valve has an adjustment cap on top.
- סטרויערן טעמפּעראַטור: Rotate the adjustment cap to increase or decrease the mixed water temperature. A thermometer should be used at the point of use to verify the desired temperature.
- באַשטעטיקן טעמפּעראַטור: Allow water to flow for a few minutes to stabilize the temperature before making final adjustments. The adjustable range is 80°F to 120°F.
The valve's internal thermostat automatically adjusts the hot and cold water flow to maintain the set temperature, even with fluctuations in supply pressures or temperatures.
5. וישאַלט
Regular maintenance is generally not required for this thermostatic mixing valve under normal operating conditions. However, periodic checks can ensure continued optimal performance.
- Annual Temperature Check: It is recommended to annually verify the mixed water temperature with a thermometer to ensure it remains within the desired and safe range.
- Inlet Strainers/Check Valves: The valve includes integral filter washers and check valves. If flow issues or inconsistent temperatures occur, these components may need inspection and cleaning. This typically requires shutting off water, disassembling the union connections, and carefully removing and cleaning the screens/check valve components.
- לעק דורכקוק: Periodically inspect all connections for any signs of leaks. Address any leaks immediately.
6. טראָובלעשאָאָטינג
| פּראָבלעם | מעגלעך סיבה | לייזונג |
|---|---|---|
| Inconsistent Mixed Water Temperature | Fluctuations in supply pressure/temperature, clogged strainers, or valve malfunction. | Verify supply pressures are stable. Clean inlet strainers. If problem persists, valve may require professional inspection or replacement. |
| No Hot Water or Too Cold Mixed Water | Hot water supply issue, cold water cross-flow, or valve stuck. | Check hot water heater. Inspect check valves for proper function. Ensure valve is not stuck in cold position. |
| No Cold Water or Too Hot Mixed Water | Cold water supply issue, hot water cross-flow, or valve stuck. | Check cold water supply. Inspect check valves. Ensure valve is not stuck in hot position. |
| רידוסט פלאָו קורס | Clogged inlet strainers or debris in the valve. | Shut off water, disassemble union connections, and clean inlet filter washers. |
| ליקס ביי קאַנעקשאַנז | Improperly tightened connections, damaged threads, or insufficient sealant. | Shut off water, re-apply pipe sealant/PTFE tape, and re-tighten connections. Replace damaged fittings if necessary. |
7. ספּעסאַפאַקיישאַנז
| אַטריביוט | דעטאַל |
|---|---|
| מאָדעל נומער | LF-MMV-M1-UT |
| סאָרט | וואטס |
| מאַטעריאַל | מעש |
| ינלעט קאַנעקשאַן טיפּ | National Pipe Tapered (FPT Union Connections) |
| נאָמינאַל גרייס | 1 אינטשעס |
| אַדזשאַסטאַבאַל טעמפּעראַטור ראַנגע | 80°F צו 120°F (26.7°C צו 48.9°C) |
| לויפן קורס | 0.5 to 12 GPM (Gallons Per Minute) |
| מאַקסימום אַפּערייטינג דרוק | 150 PSI (10.3 באַר) |
| נומער פון פּאָרץ | 3 |
| וואַלוו טיפּ | טערמאַסטאַטיק מיקסינג וואַלוו |
| Certifications/Specifications Met | ASSE 1017, ASSE 1069, ASSE 1070 |
| פּונקט וואָג | 2.94 פונט |
| פּעקל דימענשאַנז | 7.3 X 5.5 X 2.4 אינטשעס |
8. וואָראַנטי און שטיצן
For specific warranty information and technical support, please refer to the official Watts website or contact Watts customer service directly. Keep your purchase receipt for warranty claims.