tekmar 152

Tekmar Two Stage Setpoint Control 152 User Manual

מאָדעל: 152

הקדמה

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Tekmar Two Stage Setpoint Control 152. This microprocessor-based control is designed to function either as a two-stage setpoint control or as two independent setpoint controls. It supports two-stagע באַהיצונג, צוויי-סtage cooling, or a combined heating/cooling interlock function. When configured for independent operation, it can manage any combination of heating or cooling devices. Please read this manual thoroughly before installation and operation to ensure proper use and optimal performance.

זיכערקייַט אינפֿאָרמאַציע

ווארענונג: ימפּראַפּער ייַנמאָנטירונג, אַדזשאַסטמאַנט, אָלטעריישאַן, דינסט אָדער וישאַלט קענען אָנמאַכן פאַרמאָג שעדיקן, שאָדן אָדער טויט. לייענען די ייַנמאָנטירונג און אַפּערייטינג אינסטרוקציעס ונ דורך איידער איר ינסטאַלירן אָדער סערוויסינג דעם עקוויפּמענט.

פּראָדוקט איבערview

The Tekmar 152 control features a digital display and intuitive buttons for setting parameters. It is designed for precise temperature management in HVAC systems.

Tekmar Two Stage Setpoint Control 152 front view

פיגורע 1: פראָנט view of the Tekmar Two Stage Setpoint Control 152. This image shows the white rectangular control unit with a grey central panel. The panel includes a digital display at the top, three buttons below it labeled "Setpoint", "Differential", and "Delay", and two arrow buttons (up and down) for navigation. The Tekmar logo and model number "Two Stage Setpoint Control 152" are also visible.

שליסל פֿעיִקייטן:

סעטאַפּ און ינסטאַלירונג

Before beginning installation, ensure all power to the HVAC system is disconnected at the main breaker.

מאָונטינג:

  1. Select a suitable location for the control, away from direct sunlight, drafts, and heat sources.
  2. Mount the control securely to a wall or electrical box using appropriate fasteners.

וויירינג:

Refer to the wiring diagram provided with the product packaging for specific connections. General steps include:

  1. Connect the power supply wires to the designated terminals on the control.
  2. Connect the sensor wires to the sensor input terminals.
  3. Connect the output wires for heating/cooling stages to the appropriate terminals, ensuring correct polarity.
  4. Double-check all connections for tightness and correct wiring before restoring power.

Note: Professional installation is recommended to ensure compliance with all electrical codes and optimal system performance.

אַפּערייטינג ינסטראַקשאַנז

The Tekmar 152 control is operated using the three main buttons and the up/down arrow buttons on the front panel.

Setting the Setpoint:

  1. Press the "Setpoint" button. The current setpoint value will flash on the digital display.
  2. Use the "Up" or "Down" arrow buttons to adjust the setpoint to the desired temperature or value.
  3. Press the "Setpoint" button again to confirm and save the new setting, or wait a few seconds for it to save automatically.

Adjusting Differential:

The differential setting determines the temperature band around the setpoint before the control activates or deactivates a stage.

  1. Press the "Differential" button. The current differential value will flash.
  2. Use the "Up" or "Down" arrow buttons to adjust the differential.
  3. Press the "Differential" button again to confirm.

Configuring Delay:

The delay setting prevents rapid cycling of equipment, extending its lifespan.

  1. Press the "Delay" button. The current delay value will flash.
  2. Use the "Up" or "Down" arrow buttons to adjust the delay time.
  3. Press the "Delay" button again to confirm.

צוויי-זtage vs. Independent Control:

The operating mode (two-stage or independent) is typically configured during initial setup by a qualified technician. Consult your installer or the full technical manual for details on changing this mode.

וישאַלט

The Tekmar 152 control requires minimal maintenance.

Note: For any internal maintenance or repairs, contact a qualified service technician.

טראָובלעשאָאָטינג

פּראָבלעםמעגלעך סיבהלייזונג
Control display is blankקיין מאַכט צושטעלןCheck circuit breaker and wiring connections to the control.
System not responding to setpointIncorrect setpoint/differential; Sensor fault; Wiring issueVerify setpoint and differential settings. Check sensor wiring and sensor operation. Inspect output wiring.
Equipment cycles too frequentlyDifferential too small; Delay setting too shortIncrease the differential setting. Increase the delay time.
ומפּינקטלעך טעמפּעראַטור רידינגזFaulty sensor; Sensor placement issueCheck sensor for damage. Relocate sensor if it's in a draft or near a heat source.

If the problem persists after attempting these solutions, contact a qualified HVAC technician or Tekmar customer support.

ספּעסאַפאַקיישאַנז

וואָראַנטי און שטיצן

For warranty information, please refer to the documentation included with your product or visit the official Tekmar webפּלאַץ.

For technical support or service inquiries, please contact Tekmar customer service. Contact details can typically be found on the manufacturer's webזייטל אדער פּראָדוקט פּאַקאַדזשינג.

Visit the official Tekmar Store on Amazon

פֿאַרבונדענע דאָקומענטן - 152

Preview tekmar 152 Two Stage Setpoint Control: Applications, Specifications, and Wiring Diagrams
Comprehensive guide to the tekmar 152 Two Stage Setpoint Control. Explore its use in Domestic Hot Water (DHW), Pool/Spa, and Fan Coil/Slab heating systems. Includes detailed operation, specifications, settings, and electrical wiring diagrams.
Preview tekmar Wi-Fi Setpoint Control 170: Installation, Operation, and Maintenance Manual
Comprehensive guide for installing, operating, and maintaining the tekmar Wi-Fi Setpoint Control 170. Covers features, setup, applications, troubleshooting, and technical specifications for smart home climate control.
Preview Tekmar Invita 564 HVAC Interface Module and Thermostat Installation Guide
Detailed guide for installing and configuring the Tekmar Invita 564 HVAC Interface Module, WiFi Thermostat, and Outdoor Sensor with a Bosch IDS Single-Stage Furnace. Includes wiring diagrams and setup menu options.
Preview tekmar Programmable Thermostat 510 & 511 Data Brochure
Explore the tekmar Programmable Thermostat 510 and 511 with this comprehensive data brochure. Learn about features, installation, operation, sensor compatibility, and technical specifications for efficient climate control.
Preview Troubleshooting Guide for tekmar 423 Universal Reset Module
Comprehensive troubleshooting guide for the tekmar 423 Universal Reset Module, covering sensor inputs, sensor checks, outdoor sensor notes, bypassing outdoor sensor, boiler firing issues, mixing control problems, floating action valve checks, variable speed pump operation, bus configuration, and DHW settings. Includes a detailed sensor resistance table.
Preview tekmar 30XP Series Troubleshooting Guide
Comprehensive troubleshooting guide for the tekmar 30XP, 301P, 302P, 303P, 304P, and 306P zone pump controllers. Covers common issues like zone pump not turning on, no call detection, thermostat problems, and blown fuses.