עקסטעק SDL150

Extech SDL150 Dissolved Oxygen Meter SD Logger User Manual

מאָדעל: SDL150

1. הקדמה

The Extech SDL150 is a Dissolved Oxygen Meter with an integrated SD card data logger. This device is designed for precise measurement of dissolved oxygen (DO) concentration and temperature in various applications. It records data directly onto an SD card in Excel format for easy transfer and analysis on a personal computer.

Key features include a dual backlit display, automatic temperature compensation, offset adjustment for relative measurements, and user-programmable sampלינג רייץ.

Extech SDL150 Dissolved Oxygen Meter with probe

פיגורע 1: Extech SDL150 Dissolved Oxygen Meter and Probe. This image shows the main unit with its digital display and control buttons, connected to the dissolved oxygen probe.

2. פּאַקעט אינהאַלט און סעטאַפּ

2.1. פּעקל אינהאַלט

Verify that all items are present and in good condition upon unpacking. The standard package includes:

  • Extech SDL150 Dissolved Oxygen Meter
  • Dissolved Oxygen Probe with built-in temperature sensor
  • 6 רענטגענ אַאַ באַטעריז
  • SD card (2G capacity)
  • Two spare replacement membranes for the DO probe
  • Electrolyte solution for the DO probe
  • שווער קעריינג פאַל

2.2. ערשט סעטאַפּ

  1. ייַנמאָנטירונג פון באַטאַרייע: Open the battery compartment on the back of the meter and insert the 6 AA batteries, observing correct polarity.
  2. SD קאָרט ינסערשאַן: Locate the SD card slot, typically on the side of the meter. Insert the provided 2G SD card until it clicks into place.
  3. Probe Preparation:
    • Unscrew the protective cap from the dissolved oxygen probe.
    • Fill the probe's membrane cap with the supplied electrolyte solution. Ensure no air bubbles are trapped.
    • Carefully screw the membrane cap back onto the probe, ensuring the membrane is intact and free of damage.
  4. פּראָבע קשר: Connect the prepared DO probe to the designated input port on the top of the SDL150 meter.
  5. מאַכט אויף: דרוק די מאַכט קנעפּל צו קער אויף די מיטל.

3. אַפּערייטינג ינסטרוקטיאָנס

3.1. גרונטלעכע מעסטונג

  1. קאליבראציע: Before first use and periodically thereafter, calibrate the dissolved oxygen probe according to the instructions in the full user manual (not provided here). This typically involves air calibration or zero-oxygen solution calibration.
  2. טבילה: Immerse the DO probe into the sample solution. Ensure the membrane is fully submerged and free from air bubbles.
  3. לייענען ווייַז: The dual backlit display will show the dissolved oxygen concentration (in mg/L or %) and the temperature (in °F or °C).
  4. Units Selection: ניצן די פונקציע button to cycle through different measurement units (mg/L, %, °F, °C) if applicable.
Extech SDL150 Dissolved Oxygen Meter in use in a laboratory setting

פיגורע 2: Extech SDL150 in a laboratory environment. The meter is shown measuring dissolved oxygen in a beaker, demonstrating its application.

3.2. דאַטן לאָגינג

  • Manual Logging: דרוק די לאָג button to manually store the current reading. The meter can store up to 99 manual readings.
  • Automatic Logging:
    • Access the settings menu (refer to the full manual for specific button combinations) to set the desired sampלענג קורס.
    • אַמאָל די sampling rate is set, activate automatic logging. The meter will record up to 20 million readings on the 2G SD card.
    • Data is stored in Excel-compatible format for easy transfer to a PC via the SD card.

3.3. נאָך פאַנגקשאַנז

  • דאַטן האַלטן: דרוק די האַלטן קנעפּל צו איינפֿרירן די איצטיקע אויסשטעלונג. דריק נאכאמאל צו באַפֿרײַען.
  • מינימום / מאַקס: ניצן די MIN / MAX קנעפּל צו view the minimum and maximum recorded values during a measurement session.
  • באַקלייט: The display features a backlight for improved visibility in low-light conditions. Activate it using the dedicated backlight button (often indicated by a light bulb icon).
  • אַוטאָ מאַכט אַוועק: The meter includes an auto power-off function to conserve battery life. This feature can typically be disabled or adjusted in the settings.
  • אָפסעט אַדזשאַסטמאַנט: The offset adjustment function allows for zeroing the meter for relative measurements. Consult the full manual for detailed instructions on using this feature.

4. וישאַלט

4.1. Probe Membrane and Electrolyte Replacement

The dissolved oxygen probe requires periodic maintenance, specifically the replacement of the membrane and electrolyte solution. This ensures accurate readings and extends the life of the probe.

  1. Unscrew the membrane cap from the probe body.
  2. Carefully remove the old membrane and discard it.
  3. Rinse the probe tip and the inside of the new membrane cap with distilled water.
  4. Fill the new membrane cap with fresh electrolyte solution, ensuring no air bubbles are present.
  5. Gently screw the new membrane cap onto the probe body. Avoid overtightening.
  6. Allow the probe to stabilize for a few minutes before use and perform a calibration.

4.2. רייניקונג און סטאָרידזש

  • מעטער רייניקונג: ווישט אָפּ די אויסערלעכע זייט פון דעם מעטער מיט אַ ווייכן, טרוקענעם שטאָף.amp שטאָף. דו זאלסט נישט נוצן אַברייסיוו קלינערז אָדער סאָלוואַנץ.
  • זאָנד רייניקונג: After each use, rinse the probe tip with distilled water. Store the probe with its protective cap on, ideally with a small amount of electrolyte solution to keep the membrane moist, as specified in the full manual.
  • לאנג-טערמין סטאָרידזש: For extended storage, remove the batteries from the meter and ensure the probe is properly prepared as per the full manual's instructions. Store the unit and accessories in the hard carrying case in a cool, dry place.

5. טראָובלעשאָאָטינג

This section provides general guidance for common issues. For detailed troubleshooting steps, refer to the comprehensive user manual provided with your Extech SDL150.

  • קיין מאַכט: קאָנטראָלירט די אינסטאַלאַציע פון ​​די באַטעריעס און זיכערט זיך אַז זיי זענען נישט אויסגעשעפּט. טוישט אויס אויב נייטיק.
  • ומפּינקטלעך רידינגז:
    • דורכפירן אַ קאַלאַבריישאַן.
    • Check the probe membrane for damage or air bubbles. Replace the membrane and electrolyte if needed.
    • Ensure the probe is properly connected to the meter.
  • SD קאַרטל רעקאָרדירט ​​נישט:
    • Verify the SD card is correctly inserted.
    • Check if the SD card is full. Transfer data to a PC and clear the card if necessary.
    • Ensure the logging function is activated and the sampling rate is set.

6. ספּעסאַפאַקיישאַנז

פּאַראַמעטערווערט
Dissolved Oxygen Range0 to 20.0 mg/L (0 to 100.0%)
טעמפּעראַטור ראַנגע0 צו 50 ° C (32 צו 122 ° F)
מעאַסורעמענט אַקיעראַסי+/-0.5%
טעמפּעראַטור פאַרגיטיקונגAutomatic, 0 to 50°C
דאַטאַ לאָגינג קאַפּאַציטעט99 manual readings, 20M readings via 2G SD card
דאַטאַ פֿאָרמאַטExcel compatible (.xls)
פּיסי צובינדBuilt-in (via SD card)
מאַכט מקור6 x אַאַ באַטעריז (אַרייַנגערעכנט)
דימענסיעס (L X W X H)7.2 X 2.9 X 1.9 אינטשעס (18.3 X 7.4 X 4.8 סענטימעטער)
וואָג1.61 פונט (0.73 קג)

7. וואָראַנטי און שטיצן

For information regarding warranty coverage, technical support, or service, please contact Extech customer service. Refer to the official Extech website or the documentation included with your product for current contact details and warranty terms.

פאַבריקאַנט: עקסטעטש

פֿאַרבונדענע דאָקומענטן - SDL150

Preview Extech Comprehensive Catalog: Environmental Meters, Anemometers, and Test Equipment
Explore Extech's extensive range of high-quality environmental meters, thermo-anemometers, gas detectors, water quality testers, sound meters, light meters, and other precision test and measurement instruments designed for industrial, HVAC/R, and professional applications.
Preview עקסטעק 45170 4-אין-1 הומידיטי, טעמפּעראַטור, לופטפלוס, און ליכט מעטער באַניצער מאַנואַל
באַניצער מאַנואַל פֿאַר די EXTECH 45170, אַ 4-אין-1 מעטער וואָס מעסט הומידיטי, טעמפּעראַטור, לופט שטראָם און ליכט. כולל אָפּעראַציע, ספּעסיפיקאַציעס און וואָראַנטי אינפֿאָרמאַציע.
Preview מאַנואַל פֿאַר די ראַדיאַזיאָנע UV-AB Extech UV505
גאַנץ מאַנואַל פֿאַר די UV-AB Extech UV505 מיסוראַטאָרי. אַרייַננעמען אינסטרוקציעס אָפּעראַטיווע, ספּעציפיש טעכנאָלאָגיע, אינפֿאָרמאַציע און מאַנופאַקטורינג.
Preview עקסטעק UV505 UV-AB ליכט מעטער באַניצער מאַנואַל
באַניצער מאַנואַל פֿאַר די עקסטעק UV505 UV-AB ליכט מעטער. דאָס דאָקומענט גיט דעטאַלירטע אינפֿאָרמאַציע וועגן די אַפּאַראַט'ס פֿעיִקייטן, אָפּעראַציע, ספּעציפֿיקאַציעס, זיכערהייט מיטלען און וישאַלט פֿאַר מעסטן UVA און UVB ליכט.
Preview עקסטעק EX810 1000 Amp קלעממעטער מיט יר טערמאָמעטער נוצן
דעטאַילעד באַניצער-האַנדרויד פֿאַר עקסטעטש עקס810 1000 Amp קלעממעטער מיט אַ געבויט-אין יר טערמאָמעטער. באַווייזן אינסטרוקציעס, זיכערקייַט און טעכניש ספּעסאַפאַקיישאַנז פֿאַר פּינטלעך מיטינג פון ספּאַנינג, סטרים, קעגנשטעל, קאַפּאַציטעט, אָפטקייַט און טעמפּעראַטור.
Preview עקסטעק EX650 סעריע באַניצער גייד: 600A אמת RMS דיגיטאַל Clamp מעטער
א פולשטענדיקע באַניצער פירער פֿאַר די עקסטעק EX650 סעריע פון ​​600A טרו RMS דיגיטאַל קלאַוויאַטור.amp מעטערס, וואָס דעקן מאָדעלן EX650 און EX655. לערנט וועגן אָפּעראַציע, פֿעיִקייטן, זיכערקייט און ספּעציפֿיקאַציעס פֿאַר גענויע AC/DC וואָלומעןtagע, קראַנט, קעגנשטעל, און מער מעסטונגען.