Derale 13020

Derale 13020 Transmission Cooler Mounting Kit Instruction Manual

מאָדעל: 13020

1. פּראָדוקט איבערview

The Derale 13020 Transmission Cooler Mounting Kit provides essential components for installing a remote transmission cooler. This kit is designed for vehicles equipped with 5/16 inch transmission cooler lines and includes a 180-degree Fahrenheit in-line thermostat to regulate fluid temperature. It is compatible with Derale remote mount coolers and can also be used with other compatible cooler models.

Proper installation of this kit ensures efficient operation of your transmission cooler, contributing to the longevity and performance of your vehicle's transmission system.

2. קאָמפּאָנענטן רשימה

Before beginning installation, verify that all components listed below are present in your kit:

Derale 13020 Transmission Cooler Mounting Kit components including hose, fittings, thermostat, clamps, און ייַזנוואַרג.

Figure 1: All components included in the Derale 13020 Transmission Cooler Mounting Kit. This includes a coiled black rubber hose, various brass and black compression fittings, a 180-degree F in-line thermostat, metal hose clamps, bolts, washers, nuts, electrical connectors, and zip ties.

  • Transmission Hose: Flexible black rubber hose for fluid transfer.
  • 5/16 inch Compression Fittings: Brass fittings for secure hose connections (quantity: 2).
  • 180°F In-line Thermostat: Thermal switch with electrical terminals to control fluid flow or an auxiliary fan (quantity: 1).
  • Hose Barbs/Fittings: Additional black fittings for various connections (quantity: 2).
  • קישקע קלamps: מעטאַל קלamps for securing hose connections (quantity: 4).
  • מאַונטינג ייַזנוואַרג: Bolts, washers, and nuts for securing components (quantity: 4 sets).
  • עלעקטריקאַל קאַנעקטערז: Spade terminals, tap connector, and ring terminal for thermostat wiring (various).
  • זיפּ טייז: For securing hoses and wiring (quantity: 4).

3. סעטאַפּ און ייַנמאָנטירונג

זיכערקייַט פּריקאָשאַנז:

  • Ensure the vehicle is turned off, cooled down, and securely supported on jack stands or a lift.
  • Disconnect the negative battery terminal before performing any electrical work.
  • טראָגט פּאַסיקע פּערזענלעכע שוץ-עקוויפּמענט, אַרייַנגערעכנט זיכערהייט ברילן און הענטשקעס.
  • Have a drain pan ready to collect any transmission fluid that may spill.

ינסטאַלירונג סטעפּס:

  1. Identify Transmission Cooler Lines: Locate the existing transmission cooler lines on your vehicle. Typically, these run from the transmission to the radiator or an existing cooler. Consult your vehicle's service manual for specific routing.
  2. באַשטימען מאַונטינג אָרט: Choose a suitable location for your remote transmission cooler (not included) and the in-line thermostat. Ensure adequate airflow for the cooler and easy access for connections.
  3. Cut Transmission Line: Carefully cut one of the 5/16 inch transmission cooler lines at the desired point for installing the in-line thermostat or for routing to the remote cooler. Use a sharp hose cutter to ensure a clean cut.
  4. Install Compression Fittings: רוק אַ קישקע קלamp onto each end of the cut transmission line. Insert the barbed end of the 5/16 inch compression fittings into the cut lines and secure with the hose clamps. Ensure a tight, leak-free connection.
  5. פֿאַרבינדן טערמאָסטאַט: Connect the in-line thermostat into the fluid path. The thermostat is designed to open at 180°F, allowing fluid to flow to the remote cooler. Use the provided hose and additional fittings to connect the thermostat to the remote cooler and back to the transmission line. Secure all hose connections with hose clamps.
  6. בארג קאַמפּאָונאַנץ: Use the provided mounting hardware (bolts, washers, nuts) and zip ties to securely mount the remote cooler, thermostat, and any new hose runs to a stable part of the vehicle chassis. Avoid areas with excessive heat or moving parts.
  7. Electrical Connection (Thermostat): The 180°F in-line thermostat typically controls an auxiliary fan for the remote cooler. Connect the thermostat's electrical terminals using the provided spade connectors. Route wiring safely away from hot or moving components. Connect one terminal to a fused 12V ignition source and the other to the positive lead of the auxiliary fan. Ensure a proper ground connection for the fan. Consult a wiring diagram if unsure.
  8. Refill and Check Fluid: After all connections are made and secured, refill the transmission fluid to the manufacturer's recommended level. Start the engine and allow it to reach operating temperature.
  9. קאָנטראָלירן פֿאַר ליקס: Thoroughly inspect all new connections for any signs of fluid leaks. Tighten connections as necessary.

4. אָפּעראַציע

Once installed, the Derale 13020 kit facilitates the operation of your remote transmission cooler. The 180°F in-line thermostat plays a crucial role in regulating transmission fluid temperature. When the fluid temperature reaches 180°F, the thermostat will activate (e.g., open a bypass or engage an auxiliary fan), allowing the remote cooler to dissipate excess heat. This ensures that the transmission fluid operates within optimal temperature ranges, preventing overheating and maintaining fluid integrity.

The system operates automatically, requiring no manual intervention during normal driving conditions.

5. וישאַלט

Regular inspection of your transmission cooler system is recommended to ensure continued optimal performance:

  • פליסיק לעוועל טשעק: Periodically check your transmission fluid level according to your vehicle manufacturer's recommendations.
  • לעק דורכקוק: Visually inspect all hose connections, fittings, and the cooler itself for any signs of transmission fluid leaks. Address any leaks immediately.
  • שלאַנג צושטאַנד: Check the transmission hoses for cracks, hardening, or signs of wear. Replace any damaged hoses.
  • מאָונטינג זיכערהייַט: Ensure all mounted components (cooler, thermostat, hoses) remain securely fastened.
  • עלעקטריקאַל קאַנעקשאַנז: Verify that all electrical connections to the thermostat and auxiliary fan (if applicable) are clean, tight, and free from corrosion.

6. טראָובלעשאָאָטינג

If you encounter issues with your transmission cooler system after installing the Derale 13020 kit, consider the following:

  • Transmission Overheating:
    • Check for proper fluid level.
    • Ensure the remote cooler has adequate airflow and is not obstructed.
    • Verify the 180°F thermostat is functioning correctly (e.g., activating the fan or opening the fluid path when hot).
    • Inspect for kinks or blockages in the transmission lines.
  • פליסיק ליקס:
    • Re-check all hose clamps and compression fittings for tightness.
    • Inspect hoses for cuts or punctures.
    • Ensure fittings are properly seated and not cross-threaded.
  • Thermostat Malfunction:
    • Verify electrical connections to the thermostat are secure and receiving power.
    • Test the thermostat's continuity or activation point if possible (requires specialized tools).

אויב די פראבלעם מיט די פראבלעם לייזט נישט אויס, איז רעקאמענדירט צו באראטן זיך מיט א קוואַליפֿיצירטן אויטאמאטיוון טעכניקער.

7. ספּעסאַפאַקיישאַנז

שטריךבאַשרייַבונג
טייל נומער13020
Thermostat Activation Temperature180°F (82°C)
Line Compatibility5/16 inch transmission cooler lines
פּעקל דימענשאַנז (ל רענטגענ ד רענטגענ ה)9.25 X 9.25 X 4.75 אינטשעס
פּונקט וואָג2.63 פונט (1.19 קג)
לאַנד פון אָריגיןפֿאַראייניקטע שטאַטן

8. וואָראַנטי און שטיצן

For information regarding product warranty, technical support, or replacement parts, please contact Derale Performance directly through their official webזייטל אדער קונה סערוויס קאנאלן. האַלט אייער קויף קוויטל ווי אַ באַווייַז פון קויפן.

פאַבריקאַנט: Derale

Webפּלאַץ: www.derale.com

פֿאַרבונדענע דאָקומענטן - 13020

Preview דעראַלע 13021 און 15721 אין-ליין ווענטילאַטאָר טערמאָסטאַט סוויטש ינסטאַלירונג אינסטרוקציעס
דעטאַלירטע אינסטאַלאַציע אינסטרוקציעס פֿאַר די Derale 13021 און 15721 אין-ליין פאָכער טערמאָסטאַט סוויטש, אַרייַנגערעכנט קיט אינהאַלט, אויף-אַרייַנגאַנג און אין-ליין אינסטאַלאַציע פּראָוסידזשערז, וויירינג גיידאַנס, און זיכערקייַט וואָרענונגען.
Preview SPC Performance GM Torsion Key Front Leveling Kit Installation Instructions (11'-19' 8-Lug)
Detailed installation instructions for the SPC Performance GM Torsion Key Front Leveling Kit, designed for 2011-2019 8-lug GM trucks. Covers measuring ride height, removing and installing torsion keys and adjuster brackets, unloading torsion bars, and final adjustments. Includes important safety warnings and vehicle owner information.
Preview IBM Thinkpad T60 Touchpad Replacement Guide
A step-by-step guide to replacing the touchpad on an IBM Thinkpad T60 laptop, detailing the removal process with clear instructions and safety precautions.
Preview AcuRite פּראָיעקציע וועקער זייגער 13020/13026: אינסטרוקציע מאַנואַל און סעטאַפּ גייד
א פולשטענדיגע אינסטרוקציע מאנואל פאר די AcuRite פראיעקציע וועקער זייגער מאדעלן 13020 און 13026. דעקט אינפארמאציע וועגן אויפשטעלן, אייגנשאפטן, אפעראציע, פראבלעם-לייזונג, ספעציפיקאציעס, און וואראנטי.
Preview AcuRite Projection Alarm Clock 13020/13026: User Manual & Setup Guide
Comprehensive user manual for the AcuRite Projection Alarm Clock models 13020 and 13026. Learn about setup, features, operation, troubleshooting, specifications, and warranty.
Preview AcuRite פּראָיעקציע וועקער זייגער 13020/13026 אינסטרוקציע מאַנואַל
אן אויספירלעכע אינסטרוקציע מאנואל פאר די AcuRite פראיעקציע וועקער זייגער מאדעלן 13020 און 13026, וואס באדעקט סעטאפ, אפעראציע, אייגנשאפטן, טראבלושינג, און ספעציפיקאציעס.