הקדמה
The NOCO Genius GEN2 is a fully-automatic, smart marine battery charger designed for 12V onboard battery systems. This 2-bank charger provides 10 amps per bank, totaling 20 amps, for charging and maintaining lead-acid batteries. Its rugged, waterproof design (IP68 and NEMA 6P rated) ensures reliable operation in harsh marine environments, capable of submersion up to 3 meters. The GEN2 features advanced charging technology to detect, diagnose, recover, charge, and maintain various lead-acid battery types, including Wet Cell (Flooded), Gel Cell, AGM, and Deep-Cycle batteries, preventing overcharge. It incorporates safety protections against reverse polarity, sparks, short circuits, open circuits, and thermal runaway.
וואָס איז אין די קעסטל
- GEN2 On-Board Battery Charger
סעטאַפּ
מאָונטינג די טשאַרדזשער
The GEN2 charger is designed for easy installation directly onto your marine vessel or other applications. Ensure the mounting surface is secure and allows for proper cable routing. Use the provided mounting hardware to secure the unit. The charger's compact design allows for flexible placement.

Image: NOCO Genius GEN2 charger with all cables, showing its compact form factor.
באַטערי קאַנעקשאַן
פֿאַרבינדט דעם פּאָזיטיוון (+) output cable from Bank 1 to the positive terminal of your first 12V battery. Connect the negative (-) output cable from Bank 1 to the negative terminal of the same battery. Repeat this process for Bank 2 and your second 12V battery. Ensure all connections are secure and free from corrosion. The charger is designed to work with two independent 12V batteries.

בילד: אויבן view of the GEN2 charger, illustrating the separate connections for Bank 1 and Bank 2, along with the AC input.
מאַכט קאַנעקשאַן
Once batteries are securely connected, plug the AC input cord into a suitable 120V AC power outlet. The charger will automatically begin its charging process.
אַפּערייטינג ינסטראַקשאַנז
גאָר אָטאַמאַטיק אָפּעראַציע
The GEN2 charger operates automatically. Once connected to batteries and AC power, it will detect the battery condition, diagnose any issues, and begin the appropriate charging cycle without user intervention.
טשאַרדזשינג ינדיקאַטאָרס
The charger features LED indicators for each bank. A red light indicates charging in progress, and a green light indicates the battery is fully charged and in maintenance mode. These indicators provide a clear visual status of each battery's charge state.

בילד: ווינקלדיק view of the GEN2 charger, highlighting the charge status indicators for Bank 1 and Bank 2.

Image: Detailed close-up of the GEN2's charge indicators, showing the 'CHARGE' label and the 12V OUT 10A specification for each bank.
קאָמפּאַטיבלע באַטערי טייפּס
The charger is compatible with Wet Cell (Flooded), Gel Cell, AGM, and Deep-Cycle 12V lead-acid batteries ranging from 25-230Ah.
וישאַלט מאָדע
After fully charging, the GEN2 automatically transitions to a maintenance mode, continuously monitoring the battery and providing optimal charge to prevent self-discharge without overcharging. This ensures batteries remain fully charged and healthy over extended periods.
וישאַלט
רעגולער דורכקוק
Periodically inspect all cables and connections for signs of wear, damage, or corrosion. Ensure the charger's housing is clean and free from debris. Damaged cables should be replaced immediately by a qualified professional.
רייניקונג
Clean the exterior of the charger with a damp cloth. Do not use harsh chemicals or abrasive cleaners. Ensure the charger is unplugged from AC power before cleaning.
וואָטערפּרוף פּלאַן
While the charger is waterproof, ensure the AC plug and battery connections are kept dry when not in use or during installation to prevent electrical hazards. The waterproof rating applies to the main unit, not necessarily exposed connections.
טראָובלעשאָאָטינג
Charger Not Activating
- Ensure the AC power cord is securely plugged into a live outlet.
- Verify that battery connections are correct (positive to positive, negative to negative) and secure.
- קוק אויב די באַטאַרייע וואָלtage is extremely low; some chargers may require a minimum voltage to initiate charging. Consult NOCO support for very low voltage battery recovery procedures.
געפירט ינדיקאַטאָר ישוז
- If no LEDs illuminate, recheck AC power and battery connections.
- If a fault indicator (e.g., flashing red) appears, refer to the NOCO support website or contact customer service for specific fault code interpretations.
סלאָו טשאַרדזשינג
- Ensure the battery capacity is within the recommended range (25-230Ah).
- Verify that the AC power source is stable.
- Extremely cold temperatures can affect charging performance and duration.
אָוווערכיטינג
- Ensure the charger has adequate ventilation and is not covered.
- If the charger feels excessively hot, disconnect it immediately and contact support. The GEN2 has thermal protection, but persistent overheating indicates an underlying issue.
ספּעסאַפאַקיישאַנז
| שטריך | באַשרייַבונג |
|---|---|
| סאָרט | NOCO |
| מאָדעל | GEN2 |
| Ampעראַגע | 20 Ampס (10 Ampס פּער באַנק) |
| Voltage | 12 וואלטס |
| פּונקט וואָג | 9.06 פונט |
| פּראָדוקט דימענשאַנז | 9.37"ד רענטגענ 11.02"וו רענטגענ 6.3"ה |
| וואָטערפּרוף רייטינג | IP68, NEMA 6P (Submersible up to 3 meters) |
| קאָמפּאַטיבלע באַטערי טייפּס | Wet Cell (Flooded), Gel Cell, AGM, Deep-Cycle 12V Lead-Acid |
| Compatible Battery Capacity | 25-230 אַה |
| זיכערקייַט סערטיפיקאַטיאָנס | UL1236, ISO 8846 Marine Standards, Ignition Protection US Coast Guard 33 CFR 183.410 |

Image: Dimensions of the NOCO Genius GEN2 charger.
וואָראַנטי און שטיצן
וואָראַנטי
The NOCO Genius GEN2 On-Board Battery Charger is backed by a 5-Year Limited Warranty. Please retain your proof of purchase for all warranty claims. The warranty covers defects in material and workmanship under normal use.
שטיצן
For technical assistance, troubleshooting, or warranty inquiries, please visit the official NOCO website or contact their customer support directly. You can find the most current contact information and detailed support resources on the NOCO Store or their official product support pages.