Zoeller 10-0623

Zoeller 10-0623 A-Pak Indoor/Outdoor Alarm System Instruction Manual

1. פּראָדוקט איבערview

The Zoeller 10-0623 A-Pak Indoor/Outdoor Alarm System is designed to provide an audible and visual warning in the event of a high water condition. This system is suitable for various applications, including sump pumps, sewage pumps, and other wastewater management systems. It features a durable alarm unit and a reliable float switch to ensure timely alerts.

שליסל פֿעיִקייטן:

  • Horn rated at 82 decibels at 10 feet for clear audibility.
  • Integrated alarm test and horn silence switch with auto-reset functionality.
  • Terminal connections for easy integration with a pump and float switch.
  • Includes a 15-foot float switch for flexible installation.

2. זיכערקייַט אינפֿאָרמאַציע

WARNING: Risk of electrical shock. Failure to disconnect power before servicing could result in injury or death.

  • Always disconnect power to the alarm system and any connected equipment before performing installation, maintenance, or troubleshooting.
  • זיכער מאַכן אַז אַלע עלעקטרישע פֿאַרבינדונגען זענען אין לויט מיט די לאָקאַלע עלעקטרישע קאָודן און סטאַנדאַרדן.
  • This unit operates on 120 Volts. Verify the power source matches the unit's requirements.
  • Do not operate the alarm system if any components are damaged.
  • Installation should be performed by a qualified electrician or service professional.
  • האַלטן קינדער און אַנאָטערייזד פּערסאַנעל אַוועק פון די ינסטאַלירונג געגנט.

3. פּעקל אינהאַלט

באַשטעטיקן אַז אַלע זאכן זענען פאַראַן אין פּעקל:

  • Zoeller A-Pak Indoor/Outdoor Alarm Unit
  • 15 ft. Float Switch
  • Mounting Hardware (screws, clamp)
קוילעלדיק view of the Zoeller 10-0623 A-Pak Indoor/Outdoor Alarm System, including the alarm unit, float switch, and mounting hardware.

פיגורע 1: קוילעלדיק view of the Zoeller 10-0623 A-Pak Indoor/Outdoor Alarm System, including the alarm unit, float switch, and mounting hardware.

4. ינסטאַלירונג אינסטרוקציעס

4.1 Mounting the Alarm Unit

  1. Select a suitable location for the alarm unit. It can be mounted indoors or outdoors, ensuring it is easily accessible for testing and silencing.
  2. Use the provided mounting screws to securely attach the alarm unit to a wall or sturdy surface. Ensure the unit is level.
פראָנט view of the Zoeller A-Pak alarm unit, showing the red warning light, horn grille, and the test/silence switch.

פיגורע 2: פראָנט view of the Zoeller A-Pak alarm unit, showing the red warning light, horn grille, and the test/silence switch.

4.2 Installing the Float Switch

  1. Determine the desired high water level at which the alarm should activate. The float switch should be positioned so that it triggers at this level.
  2. Secure the float switch cable using the provided clamp or other suitable means, ensuring the float can move freely.
  3. Ensure the float switch is not obstructed by any pipes or other equipment within the basin אָדער טאַנק.
נאָענט-אַרויף view of the float switch with its electrical cable, which detects water levels.

פיגורע 3: נאָענט-אַרויף view of the float switch with its electrical cable, which detects water levels.

4.3 עלעקטריקאַל קאַנעקשאַנז

IMPORTANT: All electrical wiring must be performed by a qualified electrician and conform to all national and local electrical codes.

  • Ensure power is disconnected at the circuit breaker before making any connections.
  • Connect the float switch wires to the designated terminals within the alarm unit. Refer to the wiring diagram inside the alarm unit's cover for specific connections.
  • Connect the alarm unit to a dedicated 120 Volt power supply. It is recommended that the alarm unit and the pump it monitors are on separate circuits to ensure the alarm functions even if the pump's circuit blows.
  • Secure all wiring connections and ensure no bare wires are exposed.

5. אַפּערייטינג ינסטרוקטיאָנס

5.1 שרעק אַקטאַוויישאַן

The alarm system is designed to activate when the water level rises and lifts the float switch to its activation point. Upon activation:

  • The red warning light on top of the alarm unit will illuminate.
  • The audible horn will sound at 82 decibels.

5.2 שטיל מאַכן דעם אַלאַרם

To silence the audible horn after an alarm event:

  • Locate the 'SILENCE' switch on the front of the alarm unit.
  • Toggle the switch to the 'SILENCE' position. The horn will stop, but the red warning light will remain illuminated until the water level drops and the float switch deactivates.
  • The alarm system features an auto-reset function. Once the water level returns to normal and the float switch drops, the system will automatically reset, and the red warning light will turn off.

5.3 טעסטן דעם אלארם

Regular testing of the alarm system is recommended to ensure proper functionality:

  • Locate the 'TEST' switch on the front of the alarm unit.
  • Toggle the switch to the 'TEST' position. The red warning light should illuminate, and the horn should sound.
  • Return the switch to its normal operating position after testing.

6. וישאַלט

The Zoeller A-Pak alarm system requires minimal maintenance. Regular checks ensure continued reliable operation:

  • מאָנטליכע טעסט: Perform the alarm test as described in Section 5.3 to confirm the horn and light are functioning.
  • Float Switch Inspection: Periodically inspect the float switch and its cable for any signs of damage, wear, or obstruction. Ensure it moves freely.
  • ריינקייַט: Keep the alarm unit free from dust, dirt, and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
  • וויירינג קאָנטראָל: Annually, or if any issues arise, visually inspect all wiring connections for tightness and integrity. Ensure no corrosion or damage is present.

7. טראָובלעשאָאָטינג

פּראָבלעםמעגלעך סיבהלייזונג
Alarm does not sound or light up during test.קיין מאַכט צו די אַפּאַראַט.
פאַלשע וויירינג פֿאַרבינדונג.
געשעדיגטע אלארם איינהייט.
קוק די קרייַז צוימען און מאַכט צושטעלן.
באַשטעטיקן אַז אַלע עלעקטרישע פֿאַרבינדונגען זענען זיכער (מאַכן זיכער אַז די מאַכט איז ערשט אויסגעלאָשן).
Contact customer support for replacement if unit is damaged.
שרעק סאָונדס קעסיידער.Float switch stuck in 'up' position.
Actual high water condition.
פאָלטי לאָזנ שווימען באַשטימען.
Check float switch for obstructions and ensure free movement.
Investigate and resolve the high water condition.
Test float switch; replace if faulty.
Alarm does not silence.Silence switch malfunction.
Water level still high.
Ensure the silence switch is fully engaged.
The light will remain on until the water level drops and the float switch resets. Address the high water condition.
Alarm activates at incorrect water level.Float switch positioned incorrectly.
Float switch cable length incorrect.
Adjust the mounting position of the float switch to the desired activation level.
Ensure the float switch cable is secured at the correct height.

8. ספּעסאַפאַקיישאַנז

Image illustrating the dimensions of the Zoeller A-Pak alarm unit, showing a height of approximately 8.6 inches (21 cm).

Figure 4: Dimensions of the Zoeller A-Pak alarm unit.

אַטריביוטווערט
פאַבריקאַנטזאללער
מאָדעל נומער10-0623
מאַכט מקורקאָרדעד עלעקטריק
Voltage120 וואלטס
געזונט מדרגה82 דב
פּונקט וואָג3.89 פונט
פּראָדוקט דימענשאַנז8 X 13.5 X 6 אינטשעס
Float Switch Length15 פֿיס

9. וואָראַנטי און שטיצן

For specific warranty information regarding your Zoeller 10-0623 A-Pak Indoor/Outdoor Alarm System, please refer to the documentation included with your purchase or visit the official Zoeller website. If you require technical assistance, replacement parts, or have questions not covered in this manual, please contact Zoeller customer support directly.

Zoeller Company Contact Information:
Refer to the official Zoeller webזייטל אדער פּראָדוקט פּאַקאַדזשינג פֿאַר די מערסט אַקטועלע קאָנטאַקט דעטאַלן.

פֿאַרבונדענע דאָקומענטן - 10-0623

Preview זאָלער אַפּאַק אַלאַרם סיסטעמען: הויך וואַסער און זומפּ פּאָמפּע מאָניטאָרינג
לערנט וועגן זאָלער'ס APak אַלאַרם סיסטעמען, אַרייַנגערעכנט אינעווייניקסטע און דרויסנדיקע מאָדעלן מיט Z Control® פֿעיִקייטן פֿאַר פאַרלאָזלעכע הויך וואַסער אָנזאָג, פּאָמפּע דורכפאַל אַלערץ, און ווייַט מאָניטאָרינג.
Preview Zoeller 900 Series Preassembled Sump Pump Systems - Easy Installation
Discover the Zoeller 900 Series preassembled sump pump systems, designed for fast and easy installation. Features include automatic float switch, durable cast iron pump, and various basin options for residential and commercial use. Learn about model specifications and performance.
Preview Zoeller AquaNot 585 Battery Backup Pedestal Sump Pump Technical Data Sheet
Detailed technical specifications and performance data for the Zoeller AquaNot 585 Battery Backup Pedestal Sump Pump system, including product features, battery requirements, and installation cautions.
Preview זאָלער אַקוואַנאָט פיט 508/53/63/98 זומפּ פּאָמפּע סיסטעם ינסטאַלירונג גייד
קאָמפּרעהענסיווע אינסטאַלאַציע אינסטרוקציעס פֿאַר די Zoeller Aquanot Fit 508/53/63/98 פאַר-אַסעמבאַלד זומפּ פּאָמפּע סיסטעם מיט 12V DC באַטאַרייע באַקאַפּ. לערנט וועגן סעטאַפּ, אָפּעראַציע און וישאַלט.
Preview Zoeller Basement Sentry 12 Volt Backup Sump Pump System Technical Data Sheet
Technical data sheet for the Zoeller Basement Sentry 12 Volt Backup Sump Pump System, including product specifications, pump details, DC charger information, LED indicators, float switch, LCD screen, buttons, battery case, auxiliary alarm contact, technology, fittings, performance data, and warranty information.
Preview Zoeller AquaNot 508 Spin 12V DC Battery Backup Pump: Installation, Operation, and Maintenance Guide
Comprehensive installation, operation, maintenance, and troubleshooting instructions for the Zoeller AquaNot 508 Spin 12V DC Battery Backup Pump system. It details system features, warranty information, battery selection, and safety precautions.