Yellow Jacket 49965

געל דזשאַקעט 49965 טיטאַן 4-ווענטיל טעסט און טשאַרדזשינג מאַניפאָלד באַניצער מאַנואַל

מאָדעל: 49965

1. הקדמה און איבערview

The Yellow Jacket 49965 Titan 4-Valve Test and Charging Manifold is a professional-grade tool designed for comprehensive HVAC/R system diagnostics, evacuation, and charging. Its robust construction and advanced features ensure reliable performance for various refrigerant applications, particularly with R-410A.

שליסל פֿעיִקייטן אַרייַננעמען:

  • Forged Aluminum Alloy Body: Provides lightweight handling combined with durability for repeated use.
  • 4-Valve Design: Enables connection to high/low sides, refrigerant tank, and recovery unit or vacuum pump, facilitating diagnostics, evacuation, and charging without the need to switch hoses.
  • 3/8 Inch Vacuum Port: Allows for the use of a larger hose, potentially reducing evacuation time by up to 33%.
  • זיכט גלאז: Offers clear visibility of refrigerant movement and condition during charging and recovery processes.
  • Contoured Easy-Grip Handles: Designed for positive control and color-coded for quick identification.
  • Heavy Duty Hook: Engineered for secure attachment without pulling out.
Yellow Jacket 49965 Titan 4-Valve Test and Charging Manifold with red and blue gauges.

The image displays the Yellow Jacket 49965 Titan 4-Valve Manifold. It features two large, color-coded gauges: a blue low-pressure gauge on the left and a red high-pressure gauge on the right. Both gauges show scales for R-410A refrigerant, temperature in degrees Fahrenheit, and pressure in psi. The manifold body is gray, with four yellow-handled valves and multiple brass hose connections. The 'TITAN 4-Valve Manifold' and 'YELLOW JACKET' branding are visible on the central body.

2. סעטאַפּ

Before operating the manifold, ensure all components are securely connected and in good condition.

2.1 ערשט דורכקוק

  • Unpack the manifold and inspect for any visible damage.
  • Verify that all valves operate smoothly.
  • Check that the gauges are securely attached and the glass is intact.

2.2 פֿאַרבינדן שלײַכן

The 4-valve design allows for flexible connections. Typically, hoses are connected as follows:

  1. Connect the blue hose to the low-pressure side of the HVAC/R system.
  2. Connect the red hose to the high-pressure side of the HVAC/R system.
  3. Connect the yellow hose to the refrigerant tank or charging cylinder.
  4. Utilize the fourth hose connection (often the 3/8 inch vacuum port) for connection to a vacuum pump for evacuation or a recovery unit, eliminating the need to swap hoses during a service procedure.

2.3 Gauge Interpretation

The manifold features red and blue gauges calibrated for R-410A refrigerant. They display pressure in bar/psi and temperature in degrees Fahrenheit. Familiarize yourself with the scales for accurate readings.

3. אַפּערייטינג ינסטרוקטיאָנס

Always follow industry best practices and safety guidelines when working with refrigerants and HVAC/R systems.

3.1 אַלגעמיינע זיכערקייַט פּריקאָשאַנז

  • טראָגט פּאַסיקע פּערזענלעכע שוץ-עקוויפּמענט (PPE), אַרייַנגערעכנט זיכערהייטס ברילן און הענטשקעס.
  • Ensure proper ventilation when working with refrigerants.
  • Never over-pressurize a system.
  • Refer to the system manufacturer's specifications for correct pressure and charge amounts.

3.2 System Evacuation

To evacuate a system:

  1. Connect the manifold to the system and a vacuum pump via the 3/8 inch vacuum port for efficient evacuation.
  2. Open all manifold valves to allow the vacuum pump to pull a vacuum on the system.
  3. Monitor the low-pressure gauge until the desired vacuum level is achieved.
  4. Close the manifold valves and shut off the vacuum pump. Observe the gauges for any pressure rise, indicating a leak.

3.3 ריפרידזשעראַנט טשאַרדזשינג

To charge a system:

  1. Ensure the system is evacuated and leak-free.
  2. פֿאַרבינדט דעם געלן שלאַנג צום קילשטאָף טאַנק.
  3. Purge air from the yellow hose by slightly opening the tank valve and then cracking the manifold connection.
  4. Open the appropriate manifold valve (typically the low-side valve for vapor charging, or both for liquid charging with proper precautions) to allow refrigerant into the system.
  5. Monitor the system pressures on the gauges and observe refrigerant flow through the sight glass.
  6. Close the manifold valve and refrigerant tank valve once the desired charge is achieved.

3.4 System Testing and Diagnostics

With the manifold connected, you can monitor system pressures to diagnose performance issues. The sight glass aids in observing refrigerant state and oil return.

4. וישאַלט

Regular maintenance ensures the longevity and accuracy of your manifold.

  • רייניקונג: Wipe down the manifold body and gauges with a clean, damp cloth after each use. Avoid harsh chemicals that could damage the gauges or seals.
  • קישקע דורכקוק: Regularly inspect hoses for cracks, wear, or damage. Replace any compromised hoses immediately to prevent leaks.
  • וואַלוו אָפּעראַציע: Periodically check that all valves turn smoothly and seal completely when closed.
  • מאָס אַקיעראַסי: While gauges are factory calibrated, professional calibration may be required periodically to ensure continued accuracy. Consult a qualified technician for calibration services.
  • סטאָרידזש: Store the manifold in a clean, dry place, preferably in a protective case, to prevent damage.

5. טראָובלעשאָאָטינג

די סעקציע באהאנדלט אלגעמיינע פראבלעמען וואס איר קענט באגעגענען.

  • Inaccurate Gauge Readings: Ensure gauges are not damaged. Verify proper connection to the system. If persistent, professional calibration may be needed.
  • ריפרידזשעראַנט ליקס: Check all hose connections for tightness. Inspect hoses and manifold body for visible damage. Use a leak detector to pinpoint the source.
  • Valves Not Sealing: Inspect valve seats for debris or damage. If a valve does not seal, it may require servicing or replacement.

6. ספּעסאַפאַקיישאַנז

באַשרייַבונגדעטאַל
מאָדעל נומער49965
סאָרטגעל רעקל
מאַטעריאַלאַלומינום, גלאז
פֿאָדעם טיפּ3/8 Inch NPT (National Pipe Thread)
ריפרידזשעראַנט קאַמפּאַטאַבילאַטיר -410 אַ
Gauge ScaleDegrees F, bar/psi
פאַבריקאַנטFotronic Corporation
פּעקל דימענשאַנז12.5 X 12 X 5.3 אינטשעס
פּונקט וואָג6.2 פונט
UPC686800499659

7. וואָראַנטי און שטיצן

For specific warranty information regarding your Yellow Jacket 49965 Titan 4-Valve Test and Charging Manifold, please refer to the documentation provided with your purchase or contact Yellow Jacket directly. Warranty terms typically cover manufacturing defects for a specified period.

For technical support, service, or replacement parts, please contact the manufacturer or an authorized Yellow Jacket distributor. Always provide your model number (49965) when seeking support.

פֿאַרבונדענע דאָקומענטן - 49965

Preview Yellow Jacket HVAC/R Charging Systems & Diagnostic Tools Catalog
This catalog showcases Yellow Jacket's comprehensive range of HVAC/R charging systems and diagnostic tools, including the YJACK™ Series wireless sensors, P51 TITAN® Digital Manifolds, ManTooth® Wireless Gauges, and various BRUTE II® and Series 41 manifolds. The products are designed for accurate measurements, efficient system analysis, and enhanced user experience in HVAC/R applications.
Preview יעלאָו דזשאַקעט רעקאָווערXLT און רעקאָווערX קילשטאָף רעקאָווערי מאשינען
א פולשטענדיגע גייד צו יעלאָו דזשאַקעט'ס RecoverXLT און RecoverX קילשטאָף אָפּזוך מאשינען, מיט דעטאַלן פון פֿעיִקייטן, ספּעציפֿיקאַציעס, אָפּעראַציע, און פֿאַרגלייַך טשאַרץ פֿאַר HVAC/R פּראָפעסיאָנאַלן.
Preview Yellow Jacket P51-870 TITAN Digital Manifold Quick Start Guide
A quick start guide for the Yellow Jacket P51-870 TITAN Digital Manifold, covering operation modes, settings, and data management.
Preview געלע דזשאַקעט טיטאַןמאַקס™ באַניצער מאַנואַל
א פולשטענדיגע באַניצער מאַנואַל פֿאַר די YELLOW JACKET TITANMAX™ דיגיטאַל מאַניפאָולד, מיט דעטאַלן וועגן אירע פֿעיִקייטן, אָפּעראַציע, סעטטינגס, וישאַלט, און טראָובלעשווטינג פֿאַר HVAC פּראָפעסיאָנאַלס. כולל מאָדעל נומערן P/N 40880, 40881, 40885, 40887.
Preview געל דזשאַקעט TITANMAX™ דיגיטאַל מאַניפאָלד שנעל אָנהייב גייד
Quick start guide for the Yellow Jacket TITANMAX™ Digital Manifold, covering setup, connections, main features, and settings for HVAC technicians. Learn how to power on, connect probes, navigate menus, and configure settings for pressure, temperature, vacuum, and psychrometric measurements.
Preview YELLOW JACKET® TITANMAX™ Digital Manifold User Manual
Comprehensive user manual for the YELLOW JACKET® TITANMAX™ digital manifold (models 40880, 40881, 40885, 40887). Covers HVAC system diagnostics, pressure, temperature, vacuum, leak testing, psychrometric analysis, datalogging, and YJACK VIEW® app integration. Includes safety, maintenance, and troubleshooting.