APC AP7921 Switched Rack PDU User Manual

מאָדעל: אַפּ 7921

1. הקדמה און איבערview

The APC AP7921 is a Switched Rack Power Distribution Unit (PDU) designed for efficient power management in rack environments. This 1U horizontal mounting PDU provides eight (8) C13 output receptacles and accepts a 208V-230V input via an IEC-320 C20 connector, supporting a 16A single-phase load. It offers advanced features such as remote individual outlet control, local current monitoring, and remote management capabilities, making it suitable for critical IT infrastructure.

APC AP7921 Switched Rack PDU front view with 8 C13 outlets and display

פיגורע 1.1: פראָנט view of the APC AP7921 Switched Rack PDU, showing the eight C13 output receptacles and the local current monitoring display.

שליסל פֿעיִקייטן:

2. זיכערקייַט אינפֿאָרמאַציע

Read and understand all instructions before installing or operating this equipment. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. פּעקל אינהאַלט

Verify that all components are present upon unpacking. If any items are missing or damaged, contact your vendor or APC support.

4. סעטאַפּ און ייַנמאָנטירונג

4.1 געשטעל מאַונטינג

  1. Identify a 1U (1.75 inches) space in your standard 19-inch server rack.
  2. Attach the provided mounting brackets to the sides of the PDU using the included screws.
  3. Secure the PDU into the rack using appropriate rack screws, ensuring it is firmly seated.

4.2 מאַכט קאַנעקשאַן

  1. Connect the IEC-320 C20 input connector of the PDU to a compatible 208V-230V, 16A power source. Ensure the power source is properly grounded and capable of supplying the required current.
  2. Connect your IT equipment's power cords to the eight (8) C13 output receptacles on the PDU. Distribute the load evenly across the outlets if possible.

5. אָפּעראַציע

5.1 מאַכט אויף

Once the PDU is connected to a power source, it will power on automatically. The local current monitoring display will illuminate, showing the total current draw.

5.2 Local Current Monitoring

The integrated display on the front panel provides real-time information on the total current being drawn by all connected devices. This helps in preventing overloads and managing power capacity.

5.3 Remote Individual Outlet Control

The AP7921 allows for remote control of each individual C13 outlet. This feature enables users to power cycle, turn on, or turn off connected equipment remotely, which is beneficial for troubleshooting or managing power to specific devices without physical access.

5.4 Power Delays

The PDU supports configurable power-on and power-off delays for its outlets. This feature helps in sequencing the startup of equipment to prevent inrush current overloads and manage system dependencies.

6. קאָנפיגוראַטיאָן

The AP7921 PDU offers various configuration options through its network interface for remote management.

6.1 נעץ אַקסעס

Connect the PDU to your network using an Ethernet cable. Access the PDU's web interface via its assigned IP address to configure settings, monitor status, and control outlets. Refer to the network configuration guide for initial setup.

6.2 Alarm Thresholds

Configure alarm thresholds for current draw. The PDU can send alerts via email or SNMP traps if the current exceeds or falls below specified limits, helping to prevent overloads or identify power issues.

6.3 פירמוואַרע דערהייַנטיקונגען

The PDU's firmware is flash upgradeable. Regularly check the APC website for the latest firmware versions to ensure optimal performance and access to new features. Follow the provided instructions for firmware upgrade procedures.

7. וישאַלט

7.1 רייניקונג

Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents. Ensure the PDU is disconnected from the power source before cleaning.

7.2 ענוויראָנמענטאַל קאַנסידעריישאַנז

Ensure the PDU operates within its specified temperature and humidity ranges. Maintain proper airflow around the unit to prevent overheating.

8. טראָובלעשאָאָטינג

8.1 No Power to Outlets

8.2 Overload Indication

8.3 פראבלעמען מיט ווייטערן צוטריט

9. ספּעסאַפאַקיישאַנז

שטריךבאַשרייַבונג
מאָדעל נומערAP7921
אַרייַנשרייַב וואָלtage208V-230V
אַרייַנשרייַב קראַנט16 א
אַרייַנשרייַב קאַנעקטערIEC-320 C20
רעזולטאַט רעקאַפּטאַקלעס8 x IEC-320 C13
פאָרם פאַקטאָר1U Horizontal Rack-Mountable
פּראָדוקט דימענשאַנז (H x W x D)2.7 X 18.5 X 13.5 אינטשעס (בעערעך)
פּונקט וואָג1.54 פונט
שנור לענג7.8 אינטשעס
ספּעציעלע שטריךMountable, Switched Outlets, Remote Management
פאַבריקאַנטAPC

10. וואָראַנטי און שטיצן

For warranty information, technical support, or service inquiries, please refer to the official APC website or contact your local APC representative. Ensure you have your product model number (AP7921) and serial number available when contacting support.

אָנליין רעסורסן: באַזוכן www.apc.com for product documentation, software downloads, and support contact information.

פֿאַרבונדענע דאָקומענטן - AP7921

Preview APC Switched Rack Power Distribution Unit Installation Guide
Installation and operation guide for APC Switched Rack Power Distribution Units (PDUs), covering features, installation, configuration, access, warranty, and support.
Preview APC Easy PDU Metered-by-Outlet Rack Power Distribution Unit Installation Guide
Installation guide for APC Easy PDU Metered-by-Outlet Rack Power Distribution Units (EPDU2116MBO, EPDU2132MBO, EPDU2216MBO, EPDU2232MBO), covering safety, installation, display interface, and specifications.
Preview APC SMT2200/SMT3000 PDU Replacement Installation Guide | Schneider Electric
This guide provides instructions for installing an optional replacement PDU panel for APC SMT2200 and SMT3000 UPS systems. It includes important safety messages, product handling guidelines, and step-by-step installation procedures.
Preview APC NetShelter Rack PDU Advanced & Rack Systems Product Guide
Comprehensive guide to APC NetShelter Rack PDUs, including the advanced 4-in-1 outlet models, basic, metered, switched, and metered-by-outlet options for data center power management. Features specifications, accessories, and rack system solutions.
Preview אַפּק געשטעל פּאָווער דיסטריבוטיאָן יוניט ינסטאַללאַטיאָן גייד
Installation instructions for APC Rack Power Distribution Units (PDUs), including safety precautions, mounting procedures, and display interface information.
Preview APC NetShelter AR1000, AR1001, AR1100 Installation and User Manual
This manual provides detailed instructions for the installation, setup, and maintenance of American Power Conversion (APC) NetShelter rack enclosures, including models AR1000, AR1001, and AR1100. It covers product inventory, warnings, configuration, leveling, stabilization, and warranty information.