GIDIGI GX-pS01EU

GIDIGI 6-in-1 Soil pH and Humidity Tester Instruction Manual

Model: GX-pS01EU

הקדמה

This manual provides detailed instructions for the GIDIGI 6-in-1 Soil pH and Humidity Tester, model GX-pS01EU. This device is designed to measure six critical parameters for plant health: soil moisture, pH, electrical conductivity (EC), soil temperature, sunlight intensity, and air humidity. Understanding these factors helps optimize growing conditions for various plants in gardens, farms, and indoor settings.

פּראָדוקט פֿעיִקייטן

  • 6-אין-1 מולטיפונקציאָנאַליטעט: Measures soil moisture, pH, EC, temperature, sunlight, and air humidity.
  • שנעל און פּינטלעך רידינגז: Utilizes advanced probe technology for quick and precise data acquisition.
  • Large Backlit LCD Screen: Features a clear digital display with green backlighting for easy reading in various light conditions. The screen head can rotate 45° for optimal viewינג ווינקל.
  • באַניצער-פרייַנדלעך אָפּעראַציע: Simple insertion into soil, quick data display within 10 seconds, and a one-touch screen lock function.
  • ברייט אַפּלאַקיישאַן קייט: Suitable for diverse environments including gardens, farms, potted plants, succulents, and hydroponic systems.
  • מאַכט מקור: Operates on 4 AAA 1.5V batteries (included).
GIDIGI 6-in-1 Soil Tester with LCD screen inserted into soil. Measures pH, EC, temperature, soil moisture, air humidity, and light. Features a 45° angled probe and requires 4 AAA batteries.

Image: GIDIGI 6-in-1 Soil Tester with LCD screen inserted into soil. Measures pH, EC, temperature, soil moisture, air humidity, and light. Features a 45° angled probe and requires 4 AAA batteries.

קאַמפּאָונאַנץ איבערview

Diagram of the GIDIGI soil tester showing its components: LCD screen, pH, EC, Temperature, Humidity, Air Humidity, Light, Power display, Power button, HOLD/Temp button, CAL button, pH reference electrode, EC and humidity electrode, pH measurement electrode, Metal spear tip, and Battery compartment.

Image: Diagram of the GIDIGI soil tester showing its components: LCD screen, pH, EC, Temperature, Humidity, Air Humidity, Light, Power display, Power button, HOLD/Temp button, CAL button, pH reference electrode, EC and humidity electrode, pH measurement electrode, Metal spear tip, and Battery compartment.

The device consists of a main unit with an LCD screen and control buttons, and a long probe. Key components include:

  • LCD פאַרשטעלן: Displays all measurement parameters.
  • מאַכט קנעפּל: טורנס די מיטל אויף / אַוועק.
  • HOLD/Temp Button: Locks the current reading and switches between temperature units.
  • CAL קנעפּל: Used for calibration of pH and EC.
  • פּראָבע: Consists of a pH reference electrode, EC and humidity electrode, pH measurement electrode, and a metal spear tip for soil insertion.
  • באַטערי אָפּטייל: Located at the back, holds 4 AAA batteries.

סעטאַפּ און באַטעריע ינסטאַלירונג

The GIDIGI soil tester requires 4 AAA 1.5V batteries for operation. These are typically included with the product.

  1. געפֿינען די באַטאַרייע אָפּטייל אויף די צוריק פון די מיטל.
  2. עפענען די באַטאַרייע אָפּטייל דעקן.
  3. אַרײַנשטעלן 4 AAA באַטעריעס, און זיכער מאַכן אַז די פּאָלאַריטעט איז ריכטיק (+/-).
  4. פאַרמאַכן די באַטאַרייע אָפּטייל דעקן סיקיורלי.

אַפּערייטינג ינסטראַקשאַנז

Four-step diagram showing how to use the soil tester: 1. Turn on the meter. 2. Insert the probe into the soil about 2.6 inches. 3. Wait for the reading to stabilize. 4. Clean the probe thoroughly with clear water.

Image: Four-step diagram showing how to use the soil tester: 1. Turn on the meter. 2. Insert the probe into the soil about 2.6 inches. 3. Wait for the reading to stabilize. 4. Clean the probe thoroughly with clear water.

  1. מאַכט אויף: דרוק די מאַכט קנעפּל צו קער אויף די מיטל.
  2. Prepare Soil: If the soil is too dry, water the test area and wait for 10 minutes before testing. Do not insert the probe into dry, hard soil, as this may damage the tester.
  3. אַרייַנלייגן פּראָבע: Insert the probe into the soil, ensuring it covers the two small holes (lowest line) on the probe, typically about 2.6 inches (6-10 cm) deep.
  4. לייענען דאַטן: Wait approximately 10 seconds for the readings to stabilize on the LCD screen.
  5. שלאָס לייענען: Press the HOLD/Temp button to lock the current display. Press again to unlock.
  6. ריין פּראָבע: After each use, clean the sensor thoroughly with water.

קאַלאַבריישאַן

עק קאַליבראַטיאָן

The EC meter is factory calibrated. However, to maintain precision, it is recommended to calibrate it once a month.

Five-step diagram for EC calibration: 1. Clean the probe and dry it. 2. Immerse the probe in EC 1413 solution up to the lowest measurement line. 3. Press CAL to enter calibration mode (mS blinking). 4. Hold CAL for 5 seconds, then use up/down buttons to adjust the value to 1.41 mS. Release CAL. 5. Rinse the probe with filtered water.

Image: Five-step diagram for EC calibration: 1. Clean the probe and dry it. 2. Immerse the probe in EC 1413 solution up to the lowest measurement line. 3. Press CAL to enter calibration mode (mS blinking). 4. Hold CAL for 5 seconds, then use up/down buttons to adjust the value to 1.41 mS. Release CAL. 5. Rinse the probe with filtered water.

  1. Clean the probe thoroughly with water and dry it.
  2. Immerse the probe into EC 1413 calibration solution, ensuring the solution reaches the lowest measurement line on the probe.
  3. Press the "CAL" button. The "mS" indicator will blink, indicating calibration mode.
  4. Hold the "CAL" button for 5 seconds. Then, use the up/down buttons to adjust the displayed value until it reaches 1.41 mS. Release the button.
  5. Rinse the probe with filtered water after calibration.

פּה קאַלאַבריישאַן

Always start pH calibration with a pH 7.00 solution, regardless of whether you are calibrating for acidic or alkaline levels.

Four-step diagram for pH calibration: 1. Immerse the probe in pH 7.00 solution up to the lowest measurement line. 2. Press CAL, and the pH value will blink on the screen. 3. Hold CAL for 5 seconds. The calibration is complete after 3 blinks. 4. Rinse the probe with filtered water and dry excess water.

Image: Four-step diagram for pH calibration: 1. Immerse the probe in pH 7.00 solution up to the lowest measurement line. 2. Press CAL, and the pH value will blink on the screen. 3. Hold CAL for 5 seconds. The calibration is complete after 3 blinks. 4. Rinse the probe with filtered water and dry excess water.

  1. Immerse the probe into pH 7.00 calibration solution, ensuring the solution reaches the lowest measurement line.
  2. Press the "CAL" button. The pH value on the screen will blink, indicating calibration mode.
  3. Hold the "CAL" button for 5 seconds. The calibration will be completed after 3 blinks.
  4. Rinse the probe with filtered water and gently dry any excess water.

Measurement Ranges and Applications

Displaying multiple measurements including pH, light, moisture, temperature, and salinity. The device features a green LCD screen and a probe for soil insertion.

Image: Displaying multiple measurements including pH, light, moisture, temperature, and salinity. The device features a green LCD screen and a probe for soil insertion.

מעאַסורעמענט פּאַראַמעטערס:

  • pH Sensor: Range 0-14. Indicates soil acidity or alkalinity. (e.g., 3-4 Strongly Acidic, 5-6 Moderately Acidic, 7 Neutral, 8-9 Slightly Alkaline, 10-14 Strongly Alkaline)
  • Light Scale: Range 0-9999 lux. Indicates sunlight intensity. (e.g., 0-3 Dark, 3-6 Normal, 6-9 Bright)
  • Humidity Sensor (Soil): 5 levels. (e.g., 0-1 Very Dry, 2-3 Dry, 4-5 Normal, 6 Wet)
  • לופט הומידיטי: Range 0-99% RH.
  • טעמפּעראַטור: Range 0.0°C-80.0°C (32.0°F-176.0°F).
  • Salt Sensor (EC): Range 0-5000 mg/L.

טיפּיש אַפּלאַקיישאַנז:

Digital hygrometer device with LCD screen displaying temperature and humidity readings. Surrounding images show various outdoor environments where the device can be used, such as organic gardening, ornamental landscapes, trees, composting, flower pots, and seedbeds.

Image: Digital hygrometer device with LCD screen displaying temperature and humidity readings. Surrounding images show various outdoor environments where the device can be used, such as organic gardening, ornamental landscapes, trees, composting, flower pots, and seedbeds.

The GIDIGI soil tester is suitable for a wide range of applications:

  • Organic Gardening
  • Ornamental Landscapes
  • Trees and Shrubs
  • קאַמפּאָוסטינג
  • פּאָטטעד געוויקסן
  • Seedbeds and Soil Sowing
  • Hydroponic Systems (NFT, Drip, Aeroponics, Wick system, Flood & Drain, Water culture)
Image showing the GIDIGI soil tester with its probe testing the electrical conductivity of hydroponic solutions. The screen displays numerical readings, and accompanying images illustrate various hydroponic cultivation methods like NFT, Drip, Aeroponics, Wick system, Flood & Drain, and Water culture.

Image: The GIDIGI soil tester with its probe testing the electrical conductivity of hydroponic solutions. The screen displays numerical readings, and accompanying images illustrate various hydroponic cultivation methods like NFT, Drip, Aeroponics, Wick system, Flood & Drain, and Water culture.

It can be used with various soil types including common soil, coco fiber, potting mixes, sandy soil, clay soil, silty soil, and saline-alkaline soil.

Maintenance and Important Notes

Important notes for the soil tester: Do not leave the probe immersed in liquid for too long. Ensure the pH electrode is fully submerged during calibration. The EC is factory calibrated, pH should be calibrated every two weeks. Ensure the electrode is inserted 6-10 cm into the soil. Clean the pH electrode after use to prevent dirt accumulation.

Image: Important notes for the soil tester: Do not leave the probe immersed in liquid for too long. Ensure the pH electrode is fully submerged during calibration. The EC is factory calibrated, pH should be calibrated every two weeks. Ensure the electrode is inserted 6-10 cm into the soil. Clean the pH electrode after use to prevent dirt accumulation.

  • זאָנד רייניקונג: Always clean the probe thoroughly with clear water after each use to prevent residue buildup and ensure accurate future readings.
  • Avoid Prolonged Immersion: Do not leave the probe immersed in liquid for extended periods.
  • Soil Insertion Depth: For accurate readings, ensure the electrode is inserted 6-10 cm (approximately 2.6 inches) into the soil.
  • pH Calibration Frequency: While the EC is factory calibrated, pH should be calibrated every two weeks to maintain precision.
  • Dry Soil Warning: Never insert the probe into dry, hard soil without pre-watering the area, as this can damage the sensor.

טראָובלעשאָאָטינג

If you encounter issues with your GIDIGI soil tester, consider the following:

  • ומפּינקטלעך רידינגז:
    • Ensure the probe is clean and free of debris.
    • Verify that the soil is adequately moist before testing.
    • Perform a calibration for both pH and EC as described in the Calibration section.
    • Ensure the probe is inserted to the correct depth (6-10 cm).
  • קיין דיספּלעי/שוואַכע דיספּלעי:
    • Check the batteries. Replace all 4 AAA batteries if they are low or depleted.
    • זיכער מאַכן אַז די באַטעריעס זענען אַרײַנגעשטעלט מיט דער ריכטיקער פּאָלאַריטעט.
  • מיטל נישט קער אויף:
    • Confirm batteries are correctly installed and charged.
    • דריקן און האַלטן די מאַכט קנעפּל פֿאַר אַ ביסל סעקונדעס.

ספּעסאַפאַקיישאַנז

פּאַראַמעטערווערט
מאָדעל נומערGX-pS01EU
פּעקל דימענשאַנז31.5 X 10.4 X 4.4 סענטימעטער
וואָג380 גראַמז
ASINB0DW94S6XT
ערשטער בנימצא טאָג6 פעברואר 2025

שטיצן

For any questions, technical assistance, or support regarding your GIDIGI 6-in-1 Soil pH and Humidity Tester, please refer to the contact information provided with your purchase or visit the manufacturer's official webזייטל. ביטע באַהאַלטן אייער קויפן באַווייַז פֿאַר וואָראַנטי קליימז.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.