SEBSON IR_ES_EA

SEBSON Recessed Ceiling Motion Detector (IR_ES_EA) - Anthracite

ינסטראַקשאַנז מאַנואַל

1. הקדמה

Thank you for choosing the SEBSON Recessed Ceiling Motion Detector. This device is designed for indoor use to automatically control lighting based on motion and ambient light levels. Please read this manual carefully before installation and operation to ensure proper function and safety.

פראָנט view of the SEBSON recessed ceiling motion detector with key specifications overlaid: 8m/360° detection, up to 1000W LED, IP20, 10sec-30min timer, 3-2000 LUX, 230V.
פיגורע 1: איבערview of the motion detector and its main features.

2. זיכערקייַט אינסטרוקציעס

  • די אינסטאַלאַציע מוז דורכגעפירט ווערן דורך אַ קוואַליפֿיצירטן עלעקטריקער לויט די לאָקאַלע וויירינג רעגולאַציעס.
  • Disconnect power at the main circuit breaker before installation or maintenance.
  • Do not exceed the maximum load capacity of the detector (2000W for incandescent, 1000W for LED).
  • דער פּראָדוקט איז דיזיינד בלויז פֿאַר דרינענדיק נוצן. ויסמיידן ויסשטעלן צו נעץ אָדער עקסטרעם טעמפּעראַטורעס.
  • ענשור געהעריק ווענטאַליישאַן אַרום די מיטל.

3. פּראָדוקט פֿעיִקייטן

  • Indoor motion detector for recessed ceiling mounting.
  • Wide detection range of 8 meters and 360 degrees.
  • Adjustable operating duration from 10 seconds to 30 minutes.
  • Adjustable ambient light sensitivity from 3 to 2000 lux.
  • Compatible with LED lighting (max 1000W) and incandescent bulbs (max 2000W).
  • 3-wire connection for reliable operation.

4. פּעקל אינהאַלט

  • 1x SEBSON Recessed Ceiling Motion Detector (Anthracite)
  • 1x ינסטרוקטיאָן מאַנואַל

5. ינסטאַלירונג

וויכטיק: Ensure power is disconnected at the main circuit breaker before starting installation.

  1. Prepare a mounting hole in the ceiling with a diameter of 63-66 mm. Ensure there is sufficient depth (minimum 45 mm) for the detector.
  2. Connect the wiring according to the diagram below. The detector requires a 3-wire connection (Live, Neutral, Switched Live).
  3. Insert the detector into the prepared hole. The spring clips will secure it in place.
  4. Restore power and test the functionality.

5.1. פּראָדוקט איבערview און דימענשאַנז

פראָנט view of the SEBSON recessed ceiling motion detector in anthracite color.
פיגורע 2: פראָנט view of the motion detector. This image shows the anthracite-colored circular housing with the central infrared sensor dome.
Technical drawing showing the dimensions of the motion detector: 75mm diameter, 42mm height, 60mm internal width, 34mm internal height, 31mm spring length, 3mm bezel thickness.
Figure 3: Detailed dimensions of the motion detector. The overall diameter is 75mm, and the height is 42mm. The mounting hole diameter should be between 63-66mm.
זייַט view diagram illustrating the recessed installation, showing a minimum installation depth of 45mm and a ceiling thickness of up to 20mm.
Figure 4: Installation depth requirement. A minimum depth of 45mm is needed for proper recessed mounting.
דערציען view of the motion detector showing the wiring terminal block and spring clips.
פיגורע 5: דערציען view showing the wiring terminal. This is where the Live, Neutral, and Switched Live wires are connected.

6. אפערירן און אדזשאַסטמאַנץ

The motion detector features two adjustable dials on the back for 'TIME' (duration) and 'LUX' (light sensitivity).

דערציען view of the motion detector showing the 'TIME' and 'LUX' adjustment dials. The TIME dial ranges from 10s to 30min, and the LUX dial from 3 to 2000 lux.
Figure 6: Adjustment dials for TIME and LUX settings.

6.1. TIME Adjustment

The 'TIME' dial controls how long the connected light remains on after motion is detected and no further motion is sensed. Rotate the dial to set the desired duration:

  • 10 ס: Minimum duration (10 seconds).
  • 30 מינוט: Maximum duration (30 minutes).

6.2. LUX Adjustment

The 'LUX' dial determines the ambient light level at which the detector will activate. This allows the light to only turn on when it's dark enough.

  • 3: Activates only in very dark conditions (e.g., night).
  • 2000: Activates in all light conditions (day and night).

To set the LUX level, turn the dial to the sun symbol (2000 lux) for testing during daylight. Once satisfied with the detection, adjust the dial towards the moon symbol (3 lux) to the desired ambient light level for automatic operation.

6.3. דעטעקשאַן ראַנגע

Diagram showing the 360-degree detection area of the motion detector, with a maximum range of 8 meters and an installation height between 1.8m and 4m.
Figure 7: Detection range and angle. The detector covers a 360-degree area with a maximum range of 8 meters when installed at a height between 1.8m and 4m.

The detector has a 360° detection angle and a maximum range of 8 meters. Optimal installation height is between 1.8m and 4m. Avoid installing near heat sources, direct sunlight, or areas with significant air movement (e.g., air conditioning vents) to prevent false triggers.

7. וישאַלט

The SEBSON motion detector requires minimal maintenance. Ensure the sensor lens is kept clean and free from dust or obstructions. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.

8. טראָובלעשאָאָטינג

פּראָבלעם מעגלעך סיבה לייזונג
ליכט טוט נישט קער אויף.
  • קיין מאַכט צושטעלן.
  • LUX setting too low (too dark).
  • קיין באַוועגונג נישט דעטעקטירט אין דער ראַנגע.
  • פאַולטי וויירינג.
  • Check circuit breaker and connections.
  • Adjust LUX dial towards the sun symbol.
  • Ensure motion occurs within the detection zone.
  • באַשטעטיקן די וויירינג קאַנעקשאַנז.
ליכט בלייבט שטענדיק אָן.
  • Continuous motion in detection zone.
  • TIME setting too long.
  • Wiring error (e.g., switched live permanently connected).
  • Clear detection zone of constant movement.
  • Adjust TIME dial to a shorter duration.
  • Check wiring for correct connections.
Light turns on without apparent motion.
  • Heat sources (e.g., heater, direct sunlight).
  • Air currents (e.g., open window, AC vent).
  • Small animals.
  • Relocate detector or remove interfering objects.
  • Ensure stable environment.
  • Adjust sensitivity if possible (this model does not have explicit sensitivity adjustment, but careful placement can help).

9. ספּעסאַפאַקיישאַנז

סאָרט SEBSON
מאָדעל נומער IR_ES_EA
קאָליר אַנטראַסייט
דימענסיעס (L X W X H) 7.5 X 7.5 X 7.5 סענטימעטער
וואָג 110 גראַמז
מאַונטינג טיפּ רעסעססעד (סטעליע)
מאַונטינג האָלע דיאַמעטער 63-66 מם
מאַכט מקור אַק מאַכט
מאַקס לאָוד (גלייכנדיק) 2000 וו
Max Load (LED/Energy Saving) 1000 וו
דעטעקשאַן ראַנגע 8 מעטער
דעטעקשאַן ווינקל 360°
Operating Duration (TIME) 10 seconds - 30 minutes
Ambient Light Sensitivity (LUX) 3 - 2000 lux
קאַמפּאַטאַבאַל דעוויסעס Basic lighting controls
רעקאָממענדעד ניצט Residential security, commercial security, automation, energy management
לאַנד פון אָריגין כינע

10. וואָראַנטי און שטיצן

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official SEBSON webזייטל. האַלט דיין קויפן באַווייַז פֿאַר וואָראַנטי קליימז.

© 2026 SEBSON. All rights reserved.