GOYOJO GT129-B

GOYOJO Digital Gauss Meter GT129-B Instruction Manual

Model: GT129-B | Brand: GOYOJO

1. הקדמה און איבערview

The GOYOJO Digital Gauss Meter GT129-B is a precision instrument designed for accurate measurement of magnetic fields. It is suitable for various applications including permanent magnets, DC motors, magnetic separators, and industrial components with residual magnetism. This device provides precise readings up to 2000 mT (20000 Gs) and features N/S pole detection, making it an essential tool for laboratory, manufacturing, and research environments.

GOYOJO Digital Gauss Meter GT129-B displaying a magnetic field reading

Image: The GOYOJO Digital Gauss Meter GT129-B in operation, showing its display and key features.

2. פּראָדוקט פֿעיִקייטן

  • הויך פּרעסיסיאָן מעזשערמאַנט: Offers three levels of accuracy (Class 1, 2, and 5) for flexible use. Basic error is ±2% for measurements up to 1000 mT and ±5% for those above 1000 mT, ensuring reliable results.
  • אויטאָמאַטישע ראַנגע סוויטשינג: The device automatically adjusts its measurement range, switching to 2000 mT when readings exceed 200 mT.
  • Multiple Unit Display: Supports measurements in militesla (mT) and gauss (Gs), with easy conversion (1 mT = 10 Gs).
  • באַניצער-פרייַנדלעך פּלאַן: Features one-key zeroing, maximum value retention, a clear 4-digit backlit display, and automatic shutdown after 5 minutes of inactivity to conserve battery life.
  • Versatile Hall Probes: Compatible with various Hall probes for specific applications, ensuring accurate magnetic field detection across different materials and industries.
  • נידעריק מאַכט קאַנסאַמשאַן: Powered by a single 9V battery (included), offering energy efficiency and convenience for portable use.
Close-up of the GOYOJO Digital Gauss Meter's Hall probe connection and the probe itself

בילד: דעטאַלירט view of the high-standard radial Hall probe and its connection to the meter.

3. פּעקל אינהאַלט

באַשטעטיקט אַז אַלע זאכן וואָס זענען אויסגערעכנט אונטן זענען אַרייַנגערעכנט אין אייער פּעקל:

  • הויפּט אַפּאַראַט x1
  • Magnetic Probe x1
  • סטאָרידזש קאַסע x1
  • Small Screwdriver x1
  • 9 וו באַטאַרייע x1
  • באַניצער מאַנואַל x1
Contents of the GOYOJO Digital Gauss Meter GT129-B package, including the main unit, probe, case, and accessories

Image: All components included in the GOYOJO Digital Gauss Meter GT129-B package.

4. סעטאַפּ

  1. ייַנמאָנטירונג פון באַטאַרייע: Open the battery compartment on the back of the main unit. Insert the provided 9V battery, ensuring correct polarity. Close the compartment securely.
  2. פּראָבע קשר: Connect the Hall probe to the designated port on the top of the main unit. Ensure the connection is firm to prevent inaccurate readings.
  3. ערשטע איינשטראָם: דרוק די ON/OFF button to power on the device. The display will illuminate.
Diagram showing how to connect the Hall probe to the GOYOJO Digital Gauss Meter and perform a measurement

Image: Visual guide for connecting the probe and initiating a measurement.

5. אַפּערייטינג ינסטרוקטיאָנס

5.1 מאַכט אויף / אַוועק

  • דרוק די ON/OFF קנעפּל צו דרייען דעם מעטער אן אדער אויס.
  • דער מיטל וועט אויטאָמאַטיש מאַכט אַוועק נאָך 5 מינוט פון ינאַקטיוויטי.

5.2 Zeroing the Device

  • Before taking a measurement, ensure the probe is away from any magnetic fields.
  • דרוק די נול button to reset the display to 0.00 mT. This ensures accurate readings by compensating for any ambient magnetic interference.

5.3 מעאַסורינג

  • Position the Hall sensor at the tip of the probe perpendicular to the magnetic field you wish to measure.
  • The measurement value will be displayed on the screen. Allow the value to stabilize for an accurate reading.

5.4 Unit Switching (mT/Gs)

  • דרוק די UNIT button to toggle between militesla (mT) and gauss (Gs) display units. (1 mT = 10 Gs).

5.5 באַקלייט קאָנטראָל

  • דרוק די ליכט button to turn the display backlight on or off for improved visibility in various lighting conditions.
Close-up of the GOYOJO Digital Gauss Meter's backlit display and the LIGHT button

Image: The backlit display function, showing the clarity in dim conditions.

6. מעזשערמאַנט מאָדעס

6.1 שפּיץ מאָדע

  • דרוק די שפּיץ button to enter Peak Mode. In this mode, the meter will display and hold the maximum magnetic field value detected during the measurement period.

6.2 Real Mode

  • דרוק די שפּיץ button again to exit Peak Mode and return to Real Mode, where the meter displays real-time magnetic field readings.
ווייַז עקסamples of Peak Mode and Real Mode on the GOYOJO Digital Gauss Meter

Image: Comparison of Peak Mode and Real Mode displays.

7. N/S Pole Detection

The GOYOJO Digital Gauss Meter GT129-B can automatically detect and display the polarity of a magnetic field. When the magnetic field passes the front of the Hall sensor, the screen displays "N" for North pole. When it passes the back, it displays "S" for South pole. This feature is crucial for applications requiring specific magnetic orientations.

Diagram illustrating N/S pole auto-detection with a horseshoe magnet and the GOYOJO Digital Gauss Meter

Image: Visual explanation of N/S pole detection using the meter.

8. אַפּפּליקאַטיאָנס

The GOYOJO Digital Gauss Meter GT129-B is versatile and can be used in various scenarios to accurately measure working magnetic fields, surface magnetic fields, residual magnetism, and leakage magnetism. Typical applications include:

  • Guitar Pickups: Measuring magnetic field strength for audio equipment.
  • Permanent Magnets: Inspecting the strength and polarity of various permanent magnets.
  • רעדנער: Analyzing magnetic fields in speaker components.
  • Magnetic Separators: Checking the effectiveness of magnetic separation equipment.
  • Demagnetizers: Verifying the demagnetization process.
  • DC מאָטאָרס: Assessing magnetic fields within DC motor assemblies.
Collage of images showing various applications of the GOYOJO Digital Gauss Meter, including guitar pickups, permanent magnets, speakers, magnetic separators, demagnetizers, and DC motors

בילד: עקסamples of diverse applications for the digital gauss meter.

9. ספּעסאַפאַקיישאַנז

The following table outlines the technical specifications for the GOYOJO Digital Gauss Meter GT129 series, with a focus on model GT129-B:

שטריךGT129 AGT129 BGT129 C
אַקיעראַסי± 1.0%± 2.0%±2.0% (0-1000mT), ±5.0% (1000mT-2000mT)
מעאַסורינג קייט0-2000mT (20000Gs)0-2000mT (20000Gs)0-2000mT (20000Gs)
האַכלאָטע200MT resolution:0.01MT (0.1G) / 2000MT resolution:0.1MT (1G)200MT resolution:0.01MT (0.1G) / 2000MT resolution:0.1MT (1G)200MT resolution:0.01MT (0.1G) / 2000MT resolution:0.1MT (1G)
קייט200mT (2000Gs) / 2000mT (20000Gs)200mT (2000Gs) / 2000mT (20000Gs)200mT (2000Gs) / 2000mT (20000Gs)
אַוטאָ ראַנגע סוויטשFor measurements below 200mT, the range will display 200MT. For measurements above 200IT, the range will automatically switch to 2000IT.
זאָנד סענסאָרHigh-precision Hall sensor, approximately 1 meter in length
אַפּאַראַט סוויטטשינגTwo units can be switched: mT and Gs, 1MT=10Gs
באַקלייט מאָדעמיט באַקלייט
שפּיץ האָלד פֿונקציעPEAK mode can hold the maximum measurement value
אָטאַמאַטיק אַוועק5 מין
מאַכט צושטעלן9 וו באַטאַרייע x1
באַניץ סוויווע0°C~50°C, 20%~85%RH, Non-condensing
סטאָרידזש סוויווע-20°C~70°C, <85%RH, Non-condensing
גרייס160 מם × 75 מם × 34 מם
וואָגוועגן 260 ג
Detailed specifications table for GOYOJO Digital Gauss Meter models GT129 A, B, and C

Image: Comprehensive specifications for the GT129 series.

10. וישאַלט

  • רייניקונג: Use a soft, dry cloth to clean the meter's exterior. Do not use abrasive cleaners or solvents.
  • באַטערי פאַרבייַט: When the low battery indicator appears on the display, replace the 9V battery promptly to ensure continued accurate operation.
  • פּראָבע באַהאַנדלונג: Handle the Hall probe with care. Avoid bending or subjecting it to excessive force, as this can damage the sensor. Keep the probe tip clean.
  • סטאָרידזש: Store the meter and probe in the provided storage case when not in use. Keep it in a dry environment, away from extreme temperatures and direct sunlight.

11. טראָובלעשאָאָטינג

  • קיין דיספּלעי/מעטער טוט זיך נישט אן:
    • קאָנטראָלירט צי די 9V באַטאַרייע איז ריכטיק אינסטאַלירט און האט גענוג אָפּצאָל. טוישט עס אויב נייטיק.
    • פאַרזיכערן די ON/OFF button is pressed firmly.
  • ומפּינקטלעך רידינגז:
    • Perform a zero calibration by pressing the נול button in an area free of magnetic fields.
    • Ensure the Hall sensor is positioned perpendicular to the magnetic field being measured.
    • Check for any physical damage to the probe or its connection.
  • Display Backlight Not Working:
    • דרוק די ליכט button to toggle the backlight.
    • If the issue persists, the battery might be low.

12. וואָראַנטי אינפֿאָרמאַציע

For detailed warranty information regarding your GOYOJO Digital Gauss Meter GT129-B, please refer to the warranty card included in your product packaging or visit the official GOYOJO webזייטל. האַלט אייער קויף קוויטל ווי אַ באַווייַז פון קויפן פֿאַר קיין וואָראַנטי קליימז.

13. שטיצע אינפֿאָרמאַציע

Should you require technical assistance, have questions about operation, or need service for your GOYOJO Digital Gauss Meter GT129-B, please contact GOYOJO customer support. Contact details can typically be found on the official GOYOJO webפּלאַץ אָדער אין די דאַקיומענטיישאַן צוגעשטעלט מיט דיין קויפן.

פֿאַרבונדענע דאָקומענטן - GT129-B

Preview GOYOJO SRG-1 Portable Roughness Tester User Manual
User manual for the GOYOJO SRG-1 Portable Roughness Tester, detailing its features, operation, technical specifications, maintenance, and data definitions.
Preview Water Activity Meter WA-160A Calibration Guide
Step-by-step instructions for calibrating the GOYOJO Water Activity Meter WA-160A, ensuring accurate moisture readings.
Preview GOYOJO CTG Series Coating Thickness Gauge User Manual
Comprehensive user manual for the GOYOJO CTG Series (CTG1, CTG2, CTG3) coating thickness gauges. Includes setup, calibration procedures, PC software operation, and technical specifications for non-destructive material testing.
Preview PDQ GT Series Grade 1 Heavy Duty Cylindrical Lock - Architectural Submittal Sheet
Comprehensive architectural submittal sheet detailing specifications, functions, finishes, and options for the PDQ GT Series Grade 1 Heavy Duty Cylindrical Lock, designed for commercial and institutional applications.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.