Thank you for choosing the ECOELER YWT102 4-Hour Countdown Timer Switch. This device is designed to provide convenient and energy-efficient control over your lights, fans, and other household appliances by automatically turning them off after a set period. Please read this manual thoroughly before installation and operation to ensure proper use and safety.
פּראָדוקט פֿעיִקייטן
- 8 Pre-Set Countdown Options: Select from 1 min, 5 mins, 10 mins, 15 mins, 30 mins, 60 mins, 2 hours, or 4 hours.
- Manual ON/OFF Override: Easily override any countdown setting for instant control.
- ענערגיע שפּאָרן: Automatically turns off connected loads, preventing accidental energy waste.
- פּשוט אָפּעראַציע: Features a Countdown mode and a Constant On mode.
- LED ינדיקאַטאָר: A blue LED light indicates the selected time and makes the switch easy to locate in the dark.
- ברייט אַפּלאַקיישאַן: Suitable for lights, ceiling fans, bathroom fans, and heaters in various rooms like bathrooms, closets, pantries, garages, and laundry rooms.
- זיכערהייט סערטיפיקאַטיאָנס: ETL listed, supporting LED/CFL, Incandescent (800W), Fluorescent (1200VA) light bulbs, and motors (1/2 HP).

זיכערקייַט אינפֿאָרמאַציע
- ווארענונג: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that the power is off before wiring.
- ינסטאַלירן לויט אַלע נאציאנאלע און היגע עלעקטריקאַל קאָודז.
- Use only with copper or copper clad wire.
- This device requires a neutral wire for operation. If your switch box does not have a neutral wire, this product is not compatible.
- Do not exceed the maximum load ratings: 15A, 120V AC, 60Hz. Incandescent: 800W, Fluorescent: 1200VA, LED/CFL: 600W, Motor: 1/2 HP.
ייַנמאָנטירונג
Follow these steps carefully for safe and correct installation:
- קער אַוועק מאַכט: Locate the circuit breaker or fuse that controls the switch you are replacing and turn it off. Verify that the power is off using a voltagE tester.
- אַראָפּנעמען אַלטן סוויטש: Carefully remove the existing wall plate and switch from the electrical box. Disconnect the wires from the old switch.
- אידענטיפיצירן דראָטן: Identify the following wires in your electrical box:
- Load Wire (Red): Connects to the light or fan.
- Hot Wire (Black): Incoming power from the circuit breaker.
- נייטראל דראָט (ווייס): Required for this timer switch.
- Ground Wire (Green/Bare Copper): For safety.
- Wire the Timer Switch: Use the provided wire nuts to connect the wires from the electrical box to the corresponding wires on the ECOELER timer switch.
- פאַרבינדן די רויט wire from the timer to the מאַסע wire from the box.
- פאַרבינדן די שוואַרץ wire from the timer to the הייס wire from the box.
- פאַרבינדן די ווייַס wire from the timer to the נייטראַל wire from the box.
- פאַרבינדן די גרין wire from the timer to the ערד wire from the box.
- שטעלן די סוויטש: Carefully push the wired switch into the electrical box. Secure it with the mounting screws.
- ינסטאַלירן וואנט פּלאַטע: Attach the included wall plate.
- ומקערן מאַכט: קער די מאַכט צוריק אויף די קרייַז צוימען.

אָפּעראַציע
The ECOELER YWT102 timer switch offers two primary modes of operation: Countdown Mode and Constant On Mode.
קאָונטדאָוון מאָדע
This mode allows you to set the connected load to turn off automatically after a specified duration.
- אויסקלייַבן צייט: Press the "Timer Select Button" (up/down arrows) to cycle through the available countdown options: 1 min, 5 mins, 10 mins, 15 mins, 30 mins, 60 mins, 2 hours, or 4 hours. The corresponding LED indicator will light up.
- Start Countdown: Press the large "Manual ON/OFF" button once. The connected light or fan will turn on, and the countdown will begin. The timer will remember the last selected time for future use.
- Cancel Countdown: To turn off the load before the countdown completes, press the "Manual ON/OFF" button again.
Constant On Mode (Manual Override)
This mode keeps the connected load continuously on, bypassing the countdown timer.
- Activate Constant On: With the load off, press and hold the "Manual ON/OFF" button for more than 5 seconds. The load will turn on and remain on indefinitely.
- Deactivate Constant On: To turn off the load from Constant On mode, press the "Manual ON/OFF" button once.

ספּעסאַפאַקיישאַנז
| שטריך | באַשרייַבונג |
|---|---|
| מאָדעל נומער | YWT102 |
| אָפּעראַציע מאָדע | ON-OFF, Countdown Timer |
| קראַנט רייטינג | 15 Amps |
| אַפּערייטינג וואָלtage | 120 וואלטס (AC) |
| וואָסtage | 1800 וואטס |
| מאַסע קאַמפּאַטאַבילאַטי | Incandescent: 800W, Fluorescent: 1200VA, LED/CFL: 600W, Motor: 1/2 HP |
| באַשטימען טיפּ | Push Button, Countdown Timer |
| מאַונטינג טיפּ | וואנט בארג |
| קאָנטראָל מעטאָד | ריר |
| מאַטעריאַל | Copper, Metal, Polycarbonate |
| נומער דימענשאַנז (L X W X H) | 42 x 37 x 120 מילימעטער (1.65 x 1.46 x 4.72 אינטשעס) |
| אויבערשטער טעמפּעראַטור רייטינג | 50 דיגריז סעלסיוס |
| אינטערנאַציאָנאַלע פּראַטעקשאַן שאַץ | IP40 |
| סערטיפיקאַטיאָנס | FCC, cETL |
| נייטראַל דראָט פארלאנגט | יא |

טראָובלעשאָאָטינג
| פּראָבלעם | מעגלעך סיבה / לייזונג |
|---|---|
| Switch does not turn on/off. |
|
| די LED אינדיקאַטאָרן צינדן זיך נישט אָן. |
|
| Timer does not count down or turns off prematurely. |
|
וישאַלט
The ECOELER YWT102 Countdown Timer Switch requires minimal maintenance. To ensure longevity and proper function:
- רייניקונג: Wipe the switch and wall plate with a soft, damp שטאָף. דו זאלסט נישט נוצן אַברייסיוו קלינערז אָדער סאָלוואַנץ.
- רעגולער טשעקס: Periodically check for any loose connections or signs of wear. If any issues are found, turn off power at the circuit breaker before inspecting.
וואָראַנטי און שטיצן
וואָראַנטי: דער פּראָדוקט קומט מיט אַ איין יאָר וואָראַנטי פֿון די קויפן טאָג.
קונה שטיצן: If you have any questions, require assistance, or encounter issues with your ECOELER Countdown Timer Switch, please contact ECOELER ELECTRIC INC customer support.