ProLine 116-502

ProLine 116-502 Gas Ball Valve

ינסטראַקשאַנז מאַנואַל

1. פּראָדוקט איבערview

The ProLine 116-502 Gas Ball Valve is a forged brass valve designed for reliable shut-off in natural gas or LP gas applications. It features a durable 1-piece body construction and convenient 3/8-inch flare x flare connections. The valve is equipped with a chrome-plated ball and a quarter-turn lever handle for easy operation. This product is CSA 3-88 certified, ensuring compliance with safety and performance standards for gas appliances.

ProLine 116-502 Gas Ball Valve with yellow lever handle and flare connections.

This image displays the ProLine 116-502 Gas Ball Valve, featuring a brass body, a yellow quarter-turn lever handle, and 3/8-inch flare connections on both ends. The valve is designed for gas applications.

2. זיכערקייַט אינפֿאָרמאַציע

ווארענונג: ימפּראַפּער ייַנמאָנטירונג, אַדזשאַסטמאַנט, אָלטעריישאַן, דינסט אָדער וישאַלט קענען פאַרשאַפן פאַרמאָג שעדיקן, שאָדן אָדער טויט. לייענען די ייַנמאָנטירונג, אַפּערייטינג און וישאַלט אינסטרוקציעס ונ דורך איידער ינסטאָלינג אָדער סערוויסינג דעם עקוויפּמענט.

  • Always ensure gas supply is turned off before installation or maintenance.
  • די אינסטאַלאַציע מוז דורכגעפירט ווערן דורך אַ קוואַליפֿיצירטן פאַכמאַן אין לויט מיט אַלע לאָקאַלע קאָודז און רעגולאַציעס.
  • Use appropriate tools and personal protective equipment.
  • Check for leaks after installation using a non-corrosive leak detection solution.
  • Do not use open flames to check for gas leaks.
  • This valve is intended for natural gas or LP gas applications only. Do not use for other media.

3. סעטאַפּ און ייַנמאָנטירונג

This section provides general guidelines for the installation of the ProLine 116-502 Gas Ball Valve. Always refer to local plumbing and gas codes for specific requirements.

3.1 פאַר-ינסטאַלירונג טשעקס

  1. Verify that the valve model 116-502 is suitable for your specific gas application (natural gas or LP gas).
  2. Ensure the connection sizes (3/8-inch flare) match your existing piping.
  3. Inspect the valve for any visible damage before installation. Do not install a damaged valve.
  4. Gather all necessary tools, including wrenches, pipe thread sealant (if applicable for other connections in the system), and leak detection solution.

3.2 ינסטאַללאַטיאָן סטעפּס

  1. Turn off Gas Supply: Locate the main gas shut-off valve and turn off the gas supply to the area where the valve will be installed.
  2. צוגרייטן קאַנעקשאַנז: Ensure the flare connections on your gas lines are clean and free of debris.
  3. Connect Valve: Align the valve with the gas lines. Hand-tighten the flare nuts onto the valve's flare connections.
  4. פאַרשטאַרקן קאַנעקשאַנז: Using appropriate wrenches, carefully tighten the flare nuts. Do not overtighten, as this can damage the flare connections. Refer to manufacturer's recommendations for torque specifications if available, or tighten until snug and then an additional quarter to half turn.
  5. Restore Gas Supply: Slowly turn the main gas supply back on.
  6. טשעק פֿאַר ליקס: Apply a non-corrosive leak detection solution to all new connections. Bubbles indicate a leak. If a leak is detected, turn off the gas supply immediately, re-tighten the connection, and re-test. Repeat until no leaks are present.

4. אַפּערייטינג ינסטרוקטיאָנס

The ProLine 116-502 Gas Ball Valve is designed for simple on/off operation.

  • צו עפענען דעם ווענטיל: Rotate the yellow lever handle 90 degrees (a quarter-turn) so that it is parallel with the gas flow direction.
  • צו פארמאכן דעם ווענטיל: Rotate the yellow lever handle 90 degrees (a quarter-turn) so that it is perpendicular to the gas flow direction.

The quarter-turn design allows for quick and easy visual confirmation of the valve's open or closed status.

5. וישאַלט

The ProLine 116-502 Gas Ball Valve is designed for long-term, maintenance-free operation under normal conditions. Regular inspection is recommended.

  • פּעריאָדיש דורכקוק: Visually inspect the valve and connections periodically for any signs of corrosion, damage, or leaks.
  • ליק טשעקס: If you suspect a leak, perform a leak check using a non-corrosive leak detection solution.
  • רייניקונג: רייניקן די אויסערליכע זייט פון די ווענטיל מיט אדווערטייזמענטamp cloth if necessary. Do not use harsh chemicals or abrasive cleaners.
  • קיין באַניצער-סערוויסאַבלע פּאַרץ: This valve contains no user-serviceable parts. Do not attempt to disassemble or repair the valve. If the valve is damaged or malfunctioning, it must be replaced by a qualified professional.

6. טראָובלעשאָאָטינג

This section addresses common issues that may arise with gas ball valves. Always prioritize safety and consult a professional for any complex issues.

  • גאז ליק דעטעקטירט:
    • סימפּטאָם: Smell of gas, or bubbles when leak detection solution is applied.
    • אקציע: Immediately turn off the main gas supply. Re-check all connections for proper tightening. If the leak persists, do not attempt further repairs. Contact a qualified gas technician.
  • Valve Difficult to Turn:
    • סימפּטאָם: Lever handle is stiff or hard to rotate.
    • אקציע: Do not force the handle. Excessive force can damage the valve. If the valve is new, it may be slightly stiff initially. If it becomes stiff over time, it may indicate internal wear or debris. The valve should be replaced by a qualified professional.
  • קיין גאז פלוס:
    • סימפּטאָם: Appliance not receiving gas, even with valve in open position.
    • אקציע: Ensure the valve handle is fully parallel to the pipe (open position). Check other shut-off valves in the system and the main gas supply. If the issue persists, contact a qualified gas technician.

7. ספּעסאַפאַקיישאַנז

באַשרייַבונגדעטאַל
מאָדעל נומער116-502
סאָרטפּראָלינע
מאַטעריאַלForged Brass (Chrome Plated Ball)
קשר טיפּFlare x Flare
קשר גרייס3/8 inch x 3/8 inch
אָפּעראַציעQuarter-Turn Lever Handle
סערטיפיקאַטיאָנסקסאַ 3-88
אַפּפּליקאַטיאָןנאַטירלעך גאַז אָדער לפּ גאַז
פּונקט וואָג3.7 פונט (פֿאַר אַ 10-פּאַק)
פּראָדוקט דימענשאַנז (L x W x H)7.28 x 4.53 x 2.95 אינטשעס (פֿאַר 10-פּאַק)
פאַבריקאַנטB&K LLC

8. וואָראַנטי אינפֿאָרמאַציע

For specific warranty details regarding the ProLine 116-502 Gas Ball Valve, please refer to the official ProLine website or contact their customer service directly. Warranty terms typically cover manufacturing defects under normal use and service.

9. קונה שטיצן

If you have any questions, require technical assistance, or need to report an issue with your ProLine 116-502 Gas Ball Valve, please contact ProLine customer support through their official channels. Always provide the model number (116-502) when seeking support.

פֿאַר אַלגעמיינע פֿראַגעס, קענט איר באַזוכן די ProLine brand page on Amazon.

© 2024 ProLine. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.