ICOM HM195

Icom HM195 CommandMic IV Instruction Manual

Remote Control Microphone for Icom Marine Transceivers

1. פּראָדוקט איבערview

The Icom HM195 CommandMic IV is a remote control microphone designed to provide full control over compatible Icom marine transceivers. It features a user-friendly menu system with a dot-matrix display and a directional keypad for various operations and settings. This device enhances communication functionality and integration with your marine radio system.

Icom HM195 CommandMic IV

Image of the Icom HM195 CommandMic IV, a black remote control microphone with a yellow backlit LCD display.

שליסל פֿעיִקייטן:

  • Waterproof Rating: IPX7 (Submersible for 30 minutes at 1m depth)
  • ענכאַנסט געזונט קוואַליטעט
  • Complete Control Over Communications & Class D DSC Functions
  • AquaQuake Technology for water removal from the speaker
  • Full Remote Control Capability for Icom Marine Transceivers
  • User-Friendly Interface with dot-matrix display and directional keypad
  • Intercom Functionality with Compatible Transceivers
  • DSC 'Distress' Button for emergency situations

2. וואָס איז אין דער קעסטל

באַשטעטיקן אַז אַלע זאכן זענען פאַראַן ביים אויספּאַקן:

  • Icom HM195 CommandMic IV Remote Control Microphone
  • 2x OPC-1541 Extension Cables

3. סעטאַפּ און ייַנמאָנטירונג

The HM195 CommandMic IV is designed for remote installation and requires connection to a compatible Icom marine transceiver.

קאַמפּאַטאַבילאַטי:

This CommandMic is compatible with a broad range of Icom two-way radios, including but not limited to: M400BB, M410BB, M424G, M510BB, M510 Series, and M510 Evo Series.

קשר סטעפּס:

  1. Ensure the marine transceiver is powered off before connecting the CommandMic.
  2. Connect one end of an OPC-1541 extension cable to the designated CommandMic port on your Icom marine transceiver.
  3. Connect the other end of the extension cable to the HM195 CommandMic IV.
  4. For remote installations up to 18.3 meters, additional OPC-1541 extension cables may be required. Ensure all connections are secure to maintain the waterproof integrity.
  5. Once connected, power on your marine transceiver. The CommandMic IV display should illuminate, indicating a successful connection.

4. אַפּערייטינג ינסטרוקטיאָנס

The HM195 CommandMic IV provides intuitive control over your marine transceiver's functions.

מעניו נאַוויגאַציע:

  • The dot-matrix display shows various menu options and information.
  • The bottom line of the display indicates software key functions. Use the left and right buttons to toggle through these functions.
  • The directional keypad (up, down, left, right, enter) allows for navigation through menus, selection of options, and adjustment of settings.

Communication Functions:

  • שיקן / באַקומען: Use the dedicated PTT (Push-To-Talk) button for transmitting. Release to receive.
  • קאַנאַל סעלעקציע: Use the directional keypad to select desired channels.
  • באַנד אַדזשאַסטמאַנט: Adjust the speaker volume directly from the CommandMic.

דיגיטאַל סעלעקטיוו קאַלינג (DSC):

  • The CommandMic IV provides complete control over Class D DSC functions.
  • Distress Button: A dedicated DSC 'Distress' button is available for emergency situations. Refer to your transceiver's manual for proper use of this critical safety feature.

ינטערקאָם פאַנגקשאַנאַליטי:

When connected to a compatible transceiver, the CommandMic IV supports intercom functionality, allowing communication between the main transceiver unit and the remote microphone.

AquaQuake Technology:

The AquaQuake draining function emits a vibrating sound to clear water from the speaker grille, maintaining clear audio output after exposure to water.

5. וישאַלט און קער

Proper maintenance ensures the longevity and reliable operation of your HM195 CommandMic IV.

  • וואַסער קעגנשטעל: The device has an IPX7 waterproof rating, meaning it can withstand submersion in 1 meter of water for 30 minutes. Ensure all caps and connectors are securely fastened to maintain this rating.
  • רייניקונג: ווישן די אַפּאַראַט מיט אַ ווייך, דamp cloth. Do not use harsh chemicals or abrasive cleaners. For saltwater exposure, rinse thoroughly with fresh water and dry completely.
  • סטאָרידזש: Store the CommandMic in a dry, cool place when not in use. Avoid extreme temperatures and direct sunlight.

6. טראָובלעשאָאָטינג

If you encounter issues with your HM195 CommandMic IV, refer to the following basic troubleshooting steps:

  • קיין מאַכט/דיספּליי:
    • Ensure the main transceiver is powered on.
    • Check all cable connections between the CommandMic and the transceiver for security.
    • קאָנטראָלירט די קאַבלען פֿאַר יעדן קענטיקן שאָדן.
  • קיין אַודיאָ/שלעכטע אַודיאָ קוואַליטעט:
    • Adjust the volume level on the CommandMic.
    • Ensure the AquaQuake function has been used if the speaker has been exposed to water.
    • Verify that the CommandMic is properly connected to the transceiver.
  • קנעפּלעך ניט ריספּאַנדאַבאַל:
    • Restart the main transceiver.
    • זייט זיכער אז קיין שמוץ זאל נישט שטערן די קנעפלעך.

For persistent issues, consult the full manual of your Icom marine transceiver or contact Icom customer support.

7. ספּעסאַפאַקיישאַנז

סאָרט ICOM
מאָדעל נומער HM195B
וואָטערפּרוף רייטינג IPX7 (Submersible for 30 minutes at 1m depth)
דימענסיעס (L X W X H) 67.5 x 144.5 x 37 mm (Approximate)
Weight (excluding cables) 400 ג (אַפּפּראָקסימאַטע)
קאַמפּאַטאַבאַל דעוויסעס Icom two-way radios (M400BB, M410BB, M424G, M510BB, M510 Series, M510 Evo Series)
מאַכט מקור Corded Electric (powered by transceiver)
אַרייַנגערעכנט קאַמפּאָונאַנץ CommandMic™ (HM-195), 2x OPC-1541 extension cables

8. וואָראַנטי און שטיצן

For detailed warranty information, please refer to the warranty card included with your Icom marine transceiver or contact your authorized Icom dealer or the manufacturer directly. Warranty terms and conditions may vary by region and retailer.

For technical support, service, or further inquiries, please contact the retailer where the product was purchased or visit the official Icom webזייטל פֿאַר קונה שטיצע רעסורסן.

© 2023 Icom Inc. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.