Lascar EL-WiFi-TPX-

Lascar EL-WiFi-TPX+ WiFi Wireless High Accuracy Temperature Data Logger User Manual

Model: EL-WiFi-TPX+

Brand: Lascar Electronics

1. הקדמה

The Lascar EL-WiFi-TPX+ is a high-accuracy wireless temperature data logger designed for remote environmental monitoring. It utilizes an external thermistor probe to measure temperatures within a range of -40°C to +125°C (-40°F to +257°F). Data is uploaded to the EasyLog Cloud via a standard WiFi network, providing accessible monitoring from any internet-enabled device.

שליסל פֿעיִקייטן

  • Measures and records temperature using an external thermistor probe.
  • Wide temperature measurement range of -40°C to 125°C with typical ±0.2°C accuracy.
  • Equipped with audio (sounder) and visual (blinking LED) alarms for temperature breaches.
  • Enables monitoring on any device (including Android and iOS) with a web browser via the EasyLog Cloud.
  • Internal data storage ensures no data loss during WiFi disconnections, with automatic upload upon reconnection.
  • Remote configuration and alarm alerts via EasyLog Cloud.

2. פּעקל אינהאַלט

  • EL-WiFi-TPX+ Temperature Data Logger
  • 3-Meter Thermistor Probe
  • Rechargeable Lithium Battery (pre-installed or separate)
  • מיקראָ וסב קאַבלע
  • וואנט מאָונטינג קלאַמער

3. סעטאַפּ גייד

3.1 Initial Device Overview

פראָנט view of the Lascar EL-WiFi-TPX+ data logger showing the digital display with temperature reading, WiFi signal indicator, alarm light indicator, and battery level. The external thermistor probe is visible on the right side.

בילד 1: פראָנט view of the EL-WiFi-TPX+ data logger showing the digital display with temperature reading, WiFi signal indicator, alarm light indicator, and battery level. The external thermistor probe is visible on the right side.

זייַט view of the Lascar EL-WiFi-TPX+ data logger, highlighting its compact design and the connection point for the external thermistor probe.

בילד 2: זייַט view of the EL-WiFi-TPX+ data logger, highlighting its compact design and the connection point for the external thermistor probe.

3.2 באַטעריע אינסטאַלאַציע און טשאַרדזשינג

The EL-WiFi-TPX+ comes with a rechargeable lithium battery. Ensure the battery is fully charged before initial use. Connect the device to a standard USB power source using the supplied Micro USB cable. The battery indicator on the display will show charging status.

3.3 Connecting the Thermistor Probe

Carefully insert the 3-meter thermistor probe into the designated port on the side of the data logger. Ensure a secure connection for accurate temperature readings.

נאָענט-אַרויף view of the Lascar EL-WiFi-TPX+ data logger showing the external thermistor probe securely connected to the device, ready for temperature measurement.

בילד 3: נאָענט-אַרויף view of the EL-WiFi-TPX+ data logger showing the external thermistor probe securely connected to the device, ready for temperature measurement.

3.4 WiFi Network Configuration

The EL-WiFi-TPX+ connects to your WiFi network to upload data to the EasyLog Cloud.

  1. Download the EasyLog Cloud App (available for Android and iOS) or visit the EasyLog Cloud webפּלאַץ.
  2. Follow the on-screen instructions to register your device and connect it to your local WiFi network. This typically involves putting the device into setup mode and entering your network credentials.
  3. Ensure the device is within range of your WiFi router for stable connection.
Two Lascar EL-WiFi-TPX+ data loggers, one showing a temperature reading and the other indicating wireless communication, demonstrating the device's ability to connect and transmit data wirelessly.

בילד 4: Two EL-WiFi-TPX+ data loggers, one showing a temperature reading and the other indicating wireless communication, demonstrating the device's ability to connect and transmit data wirelessly.

4. אָפּעראַציע

4.1 Monitoring Temperature Data

Once configured, the device will begin measuring and logging temperature data. The current temperature is displayed on the device's screen.

פראָנט view of the Lascar EL-WiFi-TPX+ data logger displaying a temperature reading of 5.58°C on its digital screen, indicating active temperature monitoring.

בילד 5: פראָנט view of the EL-WiFi-TPX+ data logger displaying a temperature reading of 5.58°C on its digital screen, indicating active temperature monitoring.

4.2 Accessing Data via EasyLog Cloud

All logged data is periodically uploaded to the EasyLog Cloud.

  1. Log in to your EasyLog Cloud account via the app or web בלעטערער.
  2. View real-time data, historical graphs, and download data logs.
  3. Configure logging intervals, alarm thresholds, and notification settings remotely.

4.3 שרעק פאַנגקשאַנז

The EL-WiFi-TPX+ features configurable high and low temperature alarms.

If a temperature breach occurs, the device will activate its visual (blinking LED) and audio (sounder) alarms. Email alerts can also be configured through the EasyLog Cloud.

פראָנט view of the Lascar EL-WiFi-TPX+ data logger with a red glow around its edges, indicating an active alarm condition, alongside a temperature reading of 8.23°C.

בילד 6: פראָנט view of the EL-WiFi-TPX+ data logger with a red glow around its edges, indicating an active alarm condition, alongside a temperature reading of 8.23°C.

5. וישאַלט

5.1 רייניקונג

ווישט דעם אפאראט ריין מיט א ווייכן, דamp שטאָף. דו זאלסט נישט נוצן אַברייסיוו קלינערז אָדער ייַנטונקען די מיטל אין וואַסער.

5.2 באַטערי קער

To prolong battery life, avoid extreme temperatures and fully discharge and recharge the battery periodically if the device is stored for extended periods.

5.3 פּראָבע זאָרג

Handle the thermistor probe carefully. Avoid bending or kinking the cable excessively. Ensure the probe tip is clean for accurate readings.

6. טראָובלעשאָאָטינג

6.1 Device Not Connecting to WiFi

  • Ensure the device is within range of your WiFi router.
  • Verify WiFi network credentials entered during setup.
  • Check if your WiFi network is 2.4GHz (5GHz networks may not be supported).
  • Restart the data logger and your WiFi router.

6.2 אומגענויע טעמפּעראַטור מעסטונגען

  • Ensure the thermistor probe is securely connected.
  • Check if the probe tip is clean and free from obstructions.
  • Verify the probe is placed in the environment you wish to monitor, away from direct heat sources or drafts.
  • Consider recalibration if persistent inaccuracies are observed.

6.3 Alarms Not Triggering

  • Verify alarm thresholds are correctly set in the EasyLog Cloud.
  • Check if the device has a stable WiFi connection to receive updated settings.
  • Ensure the device's sounder and LED are not physically obstructed.

7. טעכניש ספּעסאַפאַקיישאַנז

שטריךדעטאַל
טעמפּעראַטור מעאַסורעמענט ראַנגע-40°C צו +125°C (-40°F צו +257°F)
אַקיעראַסיTypical ±0.2°C
קאַנעקטיוויטיWiFi
מאַכט מקורקריקאָנלאָדלעך ליטהיום פּאָלימער באַטערי
אַרייַנגערעכנט קאַמפּאָונאַנץData Logger, 3-Meter Thermistor Probe, Micro USB Cable, Wall Bracket
ווייַז טיפּדיגיטאַל
ויסווייניקסט מאַטעריאַלפּאָליקאַרבאָנאַטע (פּיסי)
פּראָדוקט קערווישן ריין
פאַבריקאַנטלאַסקאַר עלעקטראָניקס
ASINB08WRK5PN2
ערשטער בנימצא10 אפריל 2020
נומער לענג118.11 אינטשעס

8. וואָראַנטי און שטיצן

For warranty information and technical support, please refer to the official Lascar Electronics webזייטל אדער קאנטאקט זייער קאסטומער סערוויס גלייך. ספעציפישע גאראנטיע באדינגונגען קענען זיין אנדערש לויט ראיאן און קויף דאטום.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.