This manual provides essential information for the safe and efficient operation, installation, and maintenance of your FibroPool 2 HP Swimming Pool Pump (Model FP200). Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage or injury.

The FibroPool FP200 is a high-efficiency single-speed motor pump designed for in-ground pools and spas. It features a durable, corrosion-proof construction and is engineered for reliable performance.

זיכערקייַט אינפֿאָרמאַציע

Always observe basic safety precautions when installing and operating this electrical equipment. Failure to follow instructions can result in serious injury or death.

  • Ensure the pump is connected to a 240-volt, 60 Hz power supply only. It is not convertible to 120 volts.
  • די אינסטאַלאַציע מוז דורכגעפירט ווערן דורך אַ קוואַליפֿיצירטן פאַכמאַן און פאָלגן אַלע לאָקאַלע און נאַציאָנאַלע עלעקטרישע און פּלאַמבינג קאָודן.
  • שטענדיק אָפּשטעקן די מאַכט צו דער פּאָמפּע איידער איר דורכפירן קיין סערוויס אָדער וישאַלט.
  • לאָזט נישט די פּאָמפּע טרוקן לויפן. מאַכט זיכער אַז די פּאָמפּע איז אָנגעפילט מיט וואַסער איידער איר הייבט אָן.
  • Keep children away from the pump and pool equipment area.
  • Do not operate the pump if any parts are damaged or missing.

פּראָדוקט איבערview

The FibroPool FP200 pump is engineered for optimal performance and longevity. Key features include:

  • 2 horsepower motor, pushing up to 8100 GPH at 3450 RPM.
  • High-efficiency single-speed motor designed to reduce energy consumption.
  • Durable, weatherproof chassis suitable for various environments.
  • Integrated pedestal base for stable mounting.
  • Super-sized 124 cubic-inch strainer basket with a clear twist-lock lid for easy inspection and cleaning.
  • 2-inch unions included for simplified installation and servicing.
FibroPool FP200 Swimming Pool Pump, side view

פיגורע 1: זייַט view of the FibroPool FP200 Swimming Pool Pump, showing the motor and pump housing.

FibroPool FP200 Swimming Pool Pump, opposite side view

פיגור 2: קעגן-איבער זייט view of the FibroPool FP200 Swimming Pool Pump, highlighting the clear strainer lid.

ייַנמאָנטירונג

Proper installation is crucial for the pump's performance and longevity. It is recommended that installation be performed by a certified pool technician or electrician.

פּלאַץ סעלעקציע

  • Install the pump as close to the pool as possible to minimize friction loss from plumbing.
  • Ensure the location is well-ventilated and protected from direct sunlight and excessive moisture.
  • גיט גענוג פּלאַץ אַרום דער פּאָמפּע פֿאַר רוטינע וישאַלט און סערוויסינג.
  • Mount the pump on a solid, level base to prevent vibration and noise. The integrated pedestal base provides stability.

גערער קאַנעקשאַנז

  • The pump is equipped with 2-inch unions for easy connection to your existing plumbing system.
  • ניצט פּאַסיקע PVC צעמענט און פּריימער פֿאַר זיכערע, לעק-פֿרייע פֿאַרבינדונגען.
  • Ensure all plumbing is properly supported to avoid strain on the pump.

עלעקטריקאַל קאַנעקשאַנז

ווארענונג: Electrical wiring should only be performed by a licensed electrician.

  • The FibroPool FP200 operates on 240 volts, 60 Hz. Verify your power supply matches these requirements.
  • פֿאַרבינדט די פּאָמפּע צו אַ באַזונדערן קרייַז וואָס ווערט באַשיצט דורך אַ גראַונד שולד קרייַז ינטעראַפּטער (GFCI).
  • The pump includes a 6-foot weatherproof power cable. Ensure all connections are secure and weatherproof.
  • Refer to local electrical codes for specific wiring requirements.
FibroPool FP200 Swimming Pool Pump, back view מיט וויירינג

פיגורע 3: צוריק view of the FibroPool FP200 pump, showing the electrical connection box and wiring.

אַפּערייטינג ינסטראַקשאַנז

פּרימינג די פּאָמפּע

Before starting the pump for the first time, or after draining for maintenance, the pump must be primed.

  1. זיכער מאַכן אַז אַלע ווענטילן זענען אָפֿן כּדי צו דערלויבן וואַסער צו פֿליסן פֿונעם בעקן צום פּאָמפּע.
  2. Remove the clear twist-lock lid from the strainer basket.
  3. Fill the strainer basket with water until it overflows.
  4. Replace the lid, ensuring it is securely twisted and sealed.
  5. Turn on the pump. The pump should prime within a few minutes. If not, turn off the pump, re-prime, and check for air leaks in the suction line.

נאָרמאַל אָפּעראַציע

  • Once primed, the pump will circulate water through your pool system.
  • Monitor the pressure gauge on your filter system to ensure it is within the normal operating range.
  • The clear top lid allows for easy visual inspection of the strainer basket to determine when cleaning is needed.

וישאַלט

Regular maintenance ensures the longevity and efficient operation of your FibroPool pump.

זיפּ קאָרב רייניקונג

The super-sized 124 cubic-inch basket has extra leaf-holding capacity, extending time between cleanings. However, regular inspection is recommended.

  1. אויסלעשן די פּאָמפּע און אָפּשטעקן די עלעקטריע.
  2. Twist and remove the clear lid from the strainer housing.
  3. אַרויסנעמען דעם קאָרב און ליידיקן יעדן שמוץ.
  4. שווענקט דעם קאָרב גוט אויס מיט וואַסער.
  5. Inspect the O-ring on the lid for cracks or wear. Replace if necessary.
  6. Return the basket to the housing, ensuring it is seated correctly.
  7. Replace the lid, twisting it securely to create a watertight seal.
  8. אויב נייטיק, פירט ווידער אָן די פּאָמפּע איידער איר ריסטאַרט עס.

ווינטעריזאַטיאָן

In areas subject to freezing temperatures, proper winterization is essential to prevent damage.

  • אַרויסלאָזן אַלע וואַסער פֿון דער פּאָמפּע דורך אַרויסנעמען די אַראָפּגאַנג פּלאַגז.
  • Store the pump in a dry, protected area if possible.
  • Consult a pool professional for comprehensive winterization procedures for your entire pool system.

טראָובלעשאָאָטינג

This section provides solutions to common issues you may encounter with your FibroPool pump.

פּראָבלעםמעגלעך סיבהלייזונג
פּאָמפּע טוט נישט אָנהייבןNo power, tripped breaker/GFCI, faulty wiring, motor issue.Check power supply, reset breaker/GFCI. Verify electrical connections. If motor hums but doesn't start, contact a qualified technician.
Pump runs but does not prime or has low flowAir leak in suction line, clogged strainer basket, low water level in pool, closed valves, impeller obstruction.Check and seal all suction line connections. Clean strainer basket. Ensure adequate pool water level. Open all necessary valves. Inspect impeller for debris.
יבעריק ראַש אָדער ווייבריישאַןAir leak, cavitation, loose mounting, worn bearings.Check for air leaks. Ensure pump is properly primed. Tighten mounting bolts. If noise persists, motor bearings may be worn; contact service.
וואַסער ליקינג פון פּאָמפּעLoose plumbing connections, worn shaft seal, damaged O-rings.Tighten plumbing connections. Inspect and replace O-rings on strainer lid and unions. A leaking shaft seal requires professional service.

ספּעסאַפאַקיישאַנז

Detailed technical specifications for the FibroPool 2 HP Swimming Pool Pump FP200.

אַטריביוטווערט
סאָרטפיבראָפּאָאָל
מאָדעל נומערFP200
כאָרספּאַוער2 הפּ
Voltage240 וואלטס
אָפטקייַט60 הז
וואָסtage1.5 קוו
מאַקסימום לויפן קורס135 גאלאנען פּער מינוט (8100 GPH)
רפּם3450 רפּם
מאַטעריאַלAluminum (Motor), Heavy Duty Plastic (Housing)
פּונקט וואָג34.9 פונט
פּעקל דימענשאַנז25 X 14.5 X 11.5 אינטשעס
געזונט מדרגה45 דב
UPC850013473021
Performance curve chart for FibroPool pumps, showing Head vs Flow for FP100, FP150, FP200, and FP300 models.

Figure 4: Performance Curve Chart. The FP200 curve illustrates the relationship between pump head (pressure) and flow rate.

וואָראַנטי און שטיצן

For warranty information, technical support, or service inquiries, please contact FibroPool directly. Keep your purchase receipt as proof of purchase.

While specific warranty details are not provided in this manual, FibroPool is committed to providing quality products and customer satisfaction. For the most current warranty terms and conditions, please visit the official FibroPool webפּלאַץ אָדער קאָנטאַקט זייער קונה סערוויס אָפּטיילונג.

You can often find contact information on the product packaging, the manufacturer's webוועבזייטל, אדער דורך דעם פארקויפער וואו דער פראדוקט איז געקויפט געווארן.

© 2024 FibroPool. All rights reserved.

פֿאַר מער אינפֿאָרמאַציע, באַזוכן the FibroPool Store on Amazon.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.