This manual provides essential information for the safe and effective installation, operation, and maintenance of the Idec RH2B-UL-AC110-120V Electromechanical Relay. Please read this manual thoroughly before using the product to ensure proper function and to prevent potential hazards.
זיכערקייַט אינפֿאָרמאַציע
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working with the relay.
- Always ensure power is disconnected before installation, wiring, or maintenance.
- באַשטעטיקן די ריכטיק voltage and current ratings before connecting the relay to a circuit.
- Do not operate the relay in environments exceeding its specified temperature or humidity limits.
- Ensure proper grounding where applicable.
פּראָדוקט איבערview
The Idec RH2B-UL-AC110-120V is a general-purpose electromechanical relay designed for various industrial control applications. It features a compact design and is suitable for DIN rail mounting.

Figure 1: Idec RH2B-UL-AC110-120V Relays in their original packaging, showing a pack of four units.

Figure 2: A single Idec RH2B-UL-AC110-120V relay, providing an angled view of the transparent casinג און אינערלעכע קאמפאנענטן.
סעטאַפּ און ינסטאַלירונג
Follow these steps for proper installation of the Idec RH2B-UL-AC110-120V Relay:
- מאַכט דיסקאַנעקשאַן: Ensure all power to the circuit is completely disconnected before beginning installation.
- מאָונטינג: The relay is designed for DIN Rail mounting. Securely attach the relay to a standard DIN rail in your control panel.
- וויירינג: The relay utilizes through-hole connectors. Carefully connect the control circuit wiring to the coil terminals and the load circuit wiring to the contact terminals. Refer to the wiring diagram (if available in your system documentation) for specific terminal assignments.

פיגורע 3: דנאָ view of the relay, showing the through-hole connector pins for wiring connections.
- Voltage וועראַפאַקיישאַן: באַשטעטיקן אַז די צושטעלן וואָלtage for the coil matches the relay's specified voltagE פון 110-120 וו אַק, 50/60 הז.

פיגורע 4: נאָענט-אַרויף view of the relay's transparent casing, highlighting the model number and voltage specifications (AC110-120V, 50/60Hz).
- Load Verification: Ensure the connected load does not exceed the relay's contact ratings (e.g., 10A resistive at 240VAC).

פיגורע 5: זייַט view of the relay, displaying detailed electrical ratings and certifications.
- לעצט טשעק: Before restoring power, double-check all connections for security and correctness.
אַפּערייטינג ינסטראַקשאַנז
The Idec RH2B-UL-AC110-120V Relay operates automatically based on the control signal applied to its coil. When the specified AC voltage (110-120V) is applied to the coil, the relay contacts will switch, opening or closing the connected load circuit. When the voltage is removed, the contacts return to their original state.
- Ensure the control signal is within the specified voltagE קייט פֿאַר פאַרלאָזלעך אָפּעראַציע.
- Observe any indicator lights on the relay (if present) to confirm coil energization.
וישאַלט
The Idec RH2B-UL-AC110-120V Relay is designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended:
- וויסואַל דורכקוק: Periodically check the relay for any signs of physical damage, discoloration, or loose connections.
- רייניקונג: אויב נייטיק, רייניקט פֿאָרזיכטיק די אויסערלעכע זײַט פֿון רעליי מיט אַ טרוקענעם, ווייכן שטאָף. ניצט נישט קיין סאָלווענטן אָדער אַברייסיוו רייניגער.
- קאָנטאַקט דורכקוק: In critical applications, inspect contacts for pitting or wear. Replace the relay if significant wear is observed.
- ינווייראַנמענאַל טנאָים: זיכער מאַכן אַז די אָפּערייטינג סביבה בלייבט אין די ספּעציפֿיצירטע טעמפּעראַטור און הומידיטי ריינדזשאַז צו פאַרמייַדן פריצייטיגע דורכפאַל.
טראָובלעשאָאָטינג
If the relay is not functioning as expected, consider the following common issues:
| פּראָבלעם | מעגלעך סיבה | לייזונג |
|---|---|---|
| Relay coil does not energize. | No power to coil, incorrect voltage, faulty wiring, or damaged coil. | Check power supply, verify voltage (110-120V AC), inspect wiring connections, test coil continuity. |
| Contacts do not switch. | Coil not energizing, contacts welded, or mechanical failure. | Refer to "Relay coil does not energize" solutions. If coil is good, replace relay. |
| Load not receiving power. | Relay contacts not closing, open circuit in load wiring, or faulty load. | Verify relay operation. Check load circuit wiring and the load itself. |
If troubleshooting steps do not resolve the issue, contact Idec technical support or a qualified electrician.
ספּעסאַפאַקיישאַנז
| פּאַראַמעטער | ווערט |
|---|---|
| מאָדעל נומער | RH2B-UL-AC110-120V |
| סאָרט | Idec |
| שפּול וואָלtage | קסנומקס-קסנומקסוו אַק |
| אָפטקייַט | 50/60 הז |
| Current Rating (Resistive) | 10A @ 240VAC, 10A @ 30VDC |
| Current Rating (General Use) | 7.5A @ 120VAC, 7A @ 240VAC, 7.5A @ 30VDC |
| כאָרספּאַוער רייטינג | 1/6 HP @ 120VAC, 1/3 HP @ 240VAC |
| מאַונטינג טיפּ | דין רעלס בארג |
| קאַנעקטער טיפּ | דורך האָלע |
| אָפּעראַציע מאָדע | אָטאַמאַטיק |
| פּונקט וואָג | 0.01 אונסעס |
| פאַבריקאַנט | Idec |
וואָראַנטי און שטיצן
For warranty information and technical support, please contact Idec directly through their official webזייטל אדער קונה סערוויס קאנאלן. האַלט אייער קויף קוויטל פֿאַר וואָראַנטי קליימז.
Idec Official Webפּלאַץ: us.idec.com