QuietWarmth THERMST-D

QuietWarmth THERMST-D נישט-פּראָגראַמירבאַר טערמאָסטאַט באַניצער מאַנואַל

For 120V or 240V Radiant Heat Systems

1. הקדמה

The QuietWarmth THERMST-D Non-Programmable Thermostat is designed to provide reliable control for 120V or 240V electric radiant floor heating systems. This thermostat offers flexible temperature management, allowing you to configure it for control based on floor temperature, room temperature, or a combination of room temperature with a floor temperature limit. It features a built-in Ground Fault Circuit Interrupter (GFCI) for enhanced safety and a clear, backlit display for easy monitoring and operation. A floor sensor is included to ensure accurate temperature readings and optimal comfort.

פראָנט view of the QuietWarmth THERMST-D Non-Programmable Thermostat, showing the digital display and control buttons.

פיגורע 1: פראָנט view of the THERMST-D Thermostat.

2. זיכערקייַט אינפֿאָרמאַציע

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or property damage.

  • ווארענונג: To reduce the risk of electric shock, do not connect this device to a circuit with any phase operating down more than 150 volts to ground.
  • די אינסטאַלאַציע מוז דורכגעפירט ווערן דורך אַ קוואַליפֿיצירטן עלעקטריקער לויט די לאָקאַלע און נאַציאָנאַלע עלעקטרישע קאָודן.
  • The thermostat requires connection to a dedicated 20 Amp קרייַז.
  • The resistive load connected to the thermostat must not exceed 15 Amps.
  • Electric radiant floor heating systems are required by the National Electrical Code to be protected by a Ground Fault Circuit Interrupter (GFCI). This thermostat has a built-in GFCI.
  • Always turn off power at the circuit breaker before installing or servicing the thermostat.
זייַט view of the QuietWarmth THERMST-D Thermostat showing a warning label regarding electric shock risk.

פיגורע 2: זייַט view of the thermostat with safety warning label.

3. פּעקל אינהאַלט

באַשטעטיקן אַז אַלע זאכן זענען פאַראַן אין פּעקל:

  • QuietWarmth THERMST-D Non-Programmable Thermostat
  • פלאָר סענסאָר

4. פּראָדוקט איבערview

4.1 שליסל פֿעיִקייטן

  • Non-Programmable operation for radiant floor heat systems.
  • Compatible with both 120V and 240V heating systems.
  • Integrated Ground Fault Circuit Interrupter (GFCI) for safety.
  • Clear, backlit LED display for easy reading.
  • Includes a floor sensor for precise temperature control.
  • Configurable for floor temperature, room temperature, or room temperature with a floor temperature limit.
  • Seven-day energy log to monitor power consumption.
  • Supports multiple QuietWarmth mats: up to 120 sq ft for 120V systems, or 240 sq ft for 240V systems.

4.2 קאַמפּאָונאַנץ

The thermostat consists of a front display unit with control buttons and a back plate for electrical connections.

  • פראָנט פּאַנעל: Features a digital display showing time and temperature, along with 'Up', 'OK', and 'Down' buttons for navigation and setting adjustments.
  • Back Panel: Contains wiring terminals for power input (L1, L2) and load output, as well as a connection point for the floor sensor.
צוריק view of the QuietWarmth THERMST-D Thermostat showing wiring terminals labeled L1(L), L2(N), and Load, along with a mounting screw.

פיגורע 3: צוריק view of the thermostat with wiring terminals.

Image of the QuietWarmth floor sensor, a black cable with a small probe at the end.

Figure 4: Included floor sensor.

5. סעטאַפּ און ייַנמאָנטירונג

Installation should only be performed by a qualified electrician.

5.1 מאַונטינג

  • The thermostat is designed for wall mounting.
  • Ensure the mounting location is free from direct sunlight, drafts, or other heat sources that could affect temperature readings.

5.2 וויירינג

Before wiring, ensure power is OFF at the circuit breaker.

  1. Connect the thermostat to a dedicated 20 Amp קרייַז.
  2. Identify the Line (power supply) and Load (heating mat) wires.
  3. Connect the Line wires to the L1(L) and L2(N) terminals on the thermostat's back panel.
  4. Connect the Load wires from the heating mat to the 'Load' terminals on the thermostat.
  5. זיכער מאַכן אַז מען האָט אַ געהעריקע גראַונדינג לויט די לאָקאַלע עלעקטרישע קאָודן.
  6. The thermostat is dual-voltage; it can be used with either 120V or 240V heating mats, but not simultaneously. Verify your heating mat's voltagE שוועבעלעך די מאַכט צושטעלן.

5.3 Floor Sensor Placement

The floor sensor is crucial for accurate floor temperature control.

  • Place the sensor next to the long edge of the QuietWarmth heating mat.
  • Ensure the sensor is positioned in the heated area and not near any unheated zones or external heat sources.
  • Route the sensor wire carefully to avoid damage during installation of flooring materials.
An illustration showing a golden retriever dog sleeping on a floor with radiant heat film installed underneath, indicating warmth for floating floors.

פיגורע 5: עקסample of radiant heat film installation under floating floors.

An illustration showing a French bulldog puppy sleeping on a floor with radiant heat film installed underneath, indicating warmth for tile and glued floors.

פיגורע 6: עקסample of radiant heat film installation under tile and glued floors.

6. אַפּערייטינג ינסטרוקטיאָנס

6.1 מאַכט אויף

After installation, restore power at the circuit breaker. The thermostat display will illuminate.

6.2 באַשטעטיקן טעמפּעראַטור

  • ניצן די Up און אַראָפּ קנעפּלעך צו סטרויערן די געבעטן טעמפּעראַטור.
  • דרוק די OK קנעפּל צו באַשטעטיקן דיין סעלעקציע.

6.3 קאָנטראָל מאָדעס

The thermostat can be configured to operate in one of three control modes:

  • Floor Temperature Control: The thermostat maintains the floor at the set temperature using the floor sensor.
  • צימער טעמפּעראַטור קאָנטראָל: The thermostat maintains the room air temperature at the set point.
  • Room Temperature Control with Floor Limit: The thermostat primarily controls room air temperature but prevents the floor temperature from exceeding a specified maximum limit, protecting sensitive flooring materials.

Refer to the full installation guide for instructions on how to select and configure these control modes.

6.4 Energy Log

The thermostat features a seven-day energy log, allowing you to monitor the power consumption of your radiant heating system. Consult the detailed manual for accessing and interpreting this data.

7. וישאַלט

7.1 GFCI Testing

For continued safety, the built-in GFCI should be tested monthly.

  1. דרוק די פּרובירן button located on the bottom of the thermostat.
  2. The GFCI should trip, cutting power to the heating system and indicating a fault.
  3. דרוק די באַשטעטיק button to restore power.
  4. If the GFCI does not trip or reset correctly, discontinue use and contact a qualified electrician.
דנאָ view of the QuietWarmth THERMST-D Thermostat showing the GFCI test button and 'Test Monthly' text.

Figure 7: Bottom of the thermostat with GFCI test button.

7.2 רייניקונג

ווישט אָפּ די אויסערלעכע זייט פון דעם טערמאָסטאַט מיט אַ ווייכן, טרוקענעם שטאָף.amp שטאָף. דו זאלסט נישט נוצן אַברייסיוו קלינערז אָדער סאָלוואַנץ.

8. טראָובלעשאָאָטינג

If you encounter issues with your QuietWarmth THERMST-D thermostat, refer to the following common problems and solutions:

  • קיין דיספּלעי/קיין מאַכט:
    • Check the circuit breaker for the dedicated circuit and ensure it is in the ON position.
    • באַשטעטיקן אַז אַלע וויירינג קאַנעקשאַנז זענען זיכער און ריכטיק.
  • Heating System Not Activating:
    • Ensure the thermostat is set to a temperature higher than the current room or floor temperature.
    • Check if the GFCI has tripped (press the RESET button if it has).
    • Confirm the correct control mode is selected (floor, room, or room with limit).
  • GFCI Trips Frequently:
    • This indicates a ground fault. Immediately turn off power at the circuit breaker.
    • Inspect the heating mat and wiring for any damage or moisture.
    • Ensure the total resistive load does not exceed 15 Amps.
    • Contact a qualified electrician for diagnosis and repair.
  • נישט פּינקטלעכע טעמפּעראַטור מעסטונגען:
    • Verify the floor sensor is correctly installed and not damaged.
    • Ensure the thermostat is not exposed to drafts, direct sunlight, or other external heat sources.

For issues not covered here, please contact QuietWarmth customer support or a qualified electrician.

9. ספּעסאַפאַקיישאַנז

באַשרייַבונגדעטאַל
סאָרטQuietWarmth
מאָדעל נאָמעןQuietWarmth Non-Programmable Thermostat
טייל נומערטערמסט-ד
פּראָדוקט דימענשאַנז3"ד רענטגענ 4"וו רענטגענ 6"ה
פּונקט וואָג11.4 אונסעס
קאָלירווייַס
מאַטעריאַלפּלאַסטיק
Voltage120 וואלטס, 240 וואלטס
מאַקס רעזיסטיוו לאָוד15 Amps
מאַכט מקורהאַרדוויירעד
קאָנטראָללער טיפּדרוק קנעפּל
טעמפּעראַטור קאָנטראָל טיפּמאַנואַל
ווייַז טיפּLED (Backlit)
קאַנעקטיוויטי טעכנאָלאָגיעווייערד
ספּעציעלע שטריךEnergy Usage Tracking, Built-in GFCI
מאַונטינג טיפּוואנט בארג
באַשרייַבונג באגעגנטUL
UPC696087109103

10. וואָראַנטי און שטיצן

10.1 וואָראַנטי אינפֿאָרמאַציע

The QuietWarmth THERMST-D Non-Programmable Thermostat comes with a 3-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

10.2 קונה שטיצן

For technical assistance, troubleshooting, or warranty inquiries, please contact QuietWarmth customer support. Refer to the product packaging or the manufacturer's webזייטל פֿאַר איצטיקע קאָנטאַקט אינפֿאָרמאַציע.

© 2024 QuietWarmth. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.