AmScope M158C-2L

AmScope M158C-2L Cordless Compound Monocular Microscope User Manual

Model: M158C-2L

1. פּראָדוקט איבערview

The AmScope M158C-2L is a versatile cordless compound monocular microscope designed for biological and educational applications. It features interchangeable WF10x and WF25x eyepieces, providing a magnification range from 40x to 1000x. The microscope is equipped with both upper (episcopic) and lower (diascopic) LED illumination, controlled by a rheostat for adjustable brightness. Its robust design includes coaxial coarse and fine focus knobs, a single-lens condenser, and a plain stagע מיט זtage clips. This model can be powered by a 110V AC adapter or three AA batteries, offering flexibility for both lab and field use.

AmScope M158C-2L Cordless Compound Monocular Microscope

Figure 1: AmScope M158C-2L Cordless Compound Monocular Microscope. This image displays the full microscope unit, including the monocular head, objective lenses, stage, focus knobs, and power adapter.

2. זיכערקייַט אינפֿאָרמאַציע

  • Always handle the microscope with care to prevent damage to optical and mechanical components.
  • Ensure the microscope is placed on a stable, level surface to prevent tipping.
  • Do not expose the microscope to extreme temperatures, humidity, or direct sunlight.
  • Disconnect the power adapter before cleaning or performing any maintenance.
  • Use only the specified power adapter (110V) or AA batteries.
  • האַלטן קליין טיילן און אַקסעסעריז אַוועק פון קינדער צו פאַרמייַדן טשאָוקינג כאַזערדז.
  • Avoid touching optical surfaces with bare hands. Use a lens cleaning cloth if necessary.

3. וואָס איז אין דער קעסטל

באַשטעטיקט אַז אַלע קאָמפּאָנענטן וואָס זענען ליסטעד אונטן זענען אַרייַנגערעכנט אין דיין פּעקל:

  • AmScope M158C-2L microscope with plain stage
  • WF10x eyepiece
  • WF25x eyepiece
  • 4x DIN achromatic objective
  • 10x DIN achromatic objective
  • 40x DIN achromatic objective
  • (2) שtagE קליפּס
  • שטויב דעקן
  • קסנומקסוו מאַכט אַדאַפּטער
  • אינסטרוקציעס (דיזער מאַנואַל)

4. סעטאַפּ

4.1 אַנפּאַקינג און פּלייסמאַנט

  1. קערפאַלי באַזייַטיקן אַלע קאַמפּאָונאַנץ פון די פּאַקקאַגינג.
  2. Place the microscope on a sturdy, level, and vibration-free surface.
  3. אַראָפּנעמען די שטויב דעקן פון די מיקראָסקאָפּ.

4.2 אויגנשטיק אינסטאַלאַציע

  1. Gently insert either the WF10x or WF25x eyepiece into the monocular viewינג רער.
  2. Ensure the eyepiece is fully seated.

4.3 מאַכט קאַנעקשאַן

The microscope can be powered by the included AC adapter or by three AA batteries (sold separately).

  • AC מאַכט: Connect the 110V power adapter to the microscope's power input jack and then plug it into a standard electrical outlet.
  • באַטאַרייע מאַכט: Locate the battery compartment on the base of the microscope. Insert three AA batteries, ensuring correct polarity. Close the battery compartment cover securely.

5. אַפּערייטינג ינסטרוקטיאָנס

5.1 Preparing a Specimen

  1. Place your prepared slide or specimen on the plain stage.
  2. Secure the slide using the stagE קליפּס.
  3. For opaque specimens, ensure the upper LED illumination is positioned correctly. For translucent specimens, ensure the lower LED illumination is clear.
User placing a specimen slide on the microscope stage

Figure 2: User placing a specimen slide on the microscope stage. This image illustrates the proper method for securing a slide using the stage clips on the plain stage.

5.2 Selecting Magnification

  1. Rotate the revolving nosepiece to select the desired objective lens (4x, 10x, or 40x). Start with the lowest magnification (4x) for initial viewing.
  2. The total magnification is calculated by multiplying the eyepiece magnification by the objective lens magnification (e.g., WF10x eyepiece with 40x objective = 400x total magnification).

5.3 אַדזשאַסטירן באַלויכטונג

The microscope features both upper (episcopic) and lower (diascopic) LED illumination.

  • Lower Illumination (Brightfield): Used for translucent or transparent specimens. Turn on the lower LED light source. Adjust the light intensity using the rheostat control knob located on the base. The disc diaphragm below the stage can be rotated to control the amount of light passing through the specimen.
  • Upper Illumination (Incidental): Used for opaque specimens that do not allow light to pass through. Turn on the upper LED light source. Adjust the light intensity using the rheostat control knob.

5.4 פאָקוסינג

  1. With the lowest power objective (4x) in place, use the coarse focus knob (larger knob) to bring the specimen into approximate focus.
  2. Once roughly focused, use the fine focus knob (smaller knob, nested with coarse focus) for precise focusing and to achieve a sharp image.
  3. When switching to higher magnification objectives, only minor adjustments with the fine focus knob should be necessary due to the parfocal design.

5.5 ווידעא דעמאַנסטראַציע

Video 1: AmScope M158C-2L Cordless Compound Monocular Microscope Overview. This video provides a visual demonstration of the microscope's features, including its high-quality optics, dual illumination system for opaque and transparent specimens, and precision focusing capabilities.

6. וישאַלט

  • רייניקונג לענסעס: Use a soft, lint-free lens cleaning cloth and a small amount of lens cleaning solution. Wipe gently in a circular motion. Avoid using abrasive materials or harsh chemicals.
  • רייניקונג קערפער: ווישט דעם מיקראָסקאָפּ קערפּער מיט אַ ווייכן, טרוקענעם שטאָף.amp cloth. Do not use organic solvents.
  • סטאָרידזש: When not in use, cover the microscope with the provided dust cover and store it in a cool, dry place away from direct sunlight and dust.
  • באַטערי פאַרבייַט: If using battery power, replace all three AA batteries when the illumination dims significantly. Ensure correct polarity.

7. טראָובלעשאָאָטינג

פּראָבלעםמעגלעך סיבהלייזונג
קיין ילומאַניישאַןPower adapter not connected, batteries dead/incorrectly inserted, power switch off.Check power adapter connection, replace batteries, ensure power switch is on.
Image blurry/cannot focusIncorrect objective selected, coarse/fine focus not adjusted, slide upside down, dirty lens.Start with lowest objective, use coarse then fine focus, ensure slide is correct side up, clean lenses.
Dark field of viewDiaphragm closed too much, illumination too low, objective not fully clicked into place.Adjust diaphragm, increase rheostat intensity, rotate nosepiece until objective clicks.
Dust/spots in viewDust on eyepiece or objective lens.Clean eyepiece and objective lenses carefully.

8. ספּעסאַפאַקיישאַנז

שטריךדעטאַל
קאָפּCompound monocular, 45-degree fixed inclination, 360-degree rotatable
יעפּיסעסWF10x, WF25x
אַבדזשעקטיווז4x, 10x, 40x DIN achromatic
מאַגנאַפאַקיישאַן קייט40x-1000x
Stageקלאָר סtagע מיט זtagE קליפּס
ליגהטינג קאַנפיגיעריישאַןIncidental (upper) and Transmitted (lower)
קאַנדענסערSingle lens, 0.65 NA
דייאַפראַםDisc diaphragm
ליכט מקורLED with rheostat control
יללומינאַטיאָן טיפּברייטפילד
פאָקוסינגCoaxial coarse and fine focus
מאַכט110V/60Hz AC adapter or three AA batteries
פּראָדוקט דימענשאַנז10.24 X 6.69 X 14.96 אינטשעס
פּונקט וואָג4.8 פונט
מאַטעריאַלמעטאַל

9. וואָראַנטי און שטיצן

United Scope (AmScope) products are designed for durability and precision. While specific warranty details are typically provided with the product documentation, AmScope generally offers a 5-year warranty on their microscopes, covering manufacturing defects.

For technical support, warranty claims, or replacement parts, please contact AmScope customer service directly. Refer to the contact information provided on the official AmScope webזייטל אדער אין אייער פּראָדוקט'ס אָריגינעלער פּאַקאַדזשינג.

פאַבריקאַנט: AmScope

הויפּטקוואַרטיר: Irvine, CA, USA

© 2025 AmScope. All rights reserved.