AmScope SW-3T24Z Trinocular Stereo Microscope Instruction Manual

הקדמה

This manual provides detailed instructions for the safe and effective use of your AmScope SW-3T24Z Trinocular Stereo Microscope. Please read this manual thoroughly before operation and retain it for future reference. This microscope is designed for inspecting biological specimens, rocks, stamps, jewelry, and other large specimens that require handling or manipulation.

זיכערקייַט אינפֿאָרמאַציע

  • Handle the microscope with care to prevent damage to optical and mechanical components.
  • Avoid exposing the microscope to direct sunlight, high temperatures, or high humidity.
  • Keep the microscope away from dust and corrosive chemicals.
  • Ensure the microscope is placed on a stable, level surface to prevent tipping.
  • Do not attempt to disassemble or repair the microscope yourself. Contact qualified service personnel for assistance.

פּעקל אינהאַלט

באַשטעטיקן אַז אַלע קאָמפּאָנענטן זענען פאַראַן אין דער פּאַקעט:

  • Trinocular stereo zoom head with 2x/4x objective
  • WH10x eyepieces (one pair)
  • 2.0x Barlow אָביעקטיוו
  • Single-arm boom stand with focus rack
  • Eye guards (one pair)

סעטאַפּ אינסטרוקציעס

Follow these steps to assemble your AmScope SW-3T24Z microscope:

  1. אָפּלייגן קאַמפּאָונאַנץ: Carefully remove all parts from the packaging and place them on a clean, stable surface.
  2. Assemble the Boom Stand: Attach the vertical pillar to the heavy base using the provided screws. Ensure it is securely fastened.
  3. Attach Horizontal Arm: Slide the horizontal boom arm into the clamp on the vertical pillar. Adjust its position and tighten the knob to secure it.
  4. Mount Microscope Head: Insert the microscope head into the mounting ring at the end of the horizontal arm. Secure it by tightening the set screw.
AmScope SW-3T24Z Trinocular Stereo Microscope assembled on its boom stand, side view.

Figure 1: Assembled AmScope SW-3T24Z Trinocular Stereo Microscope.

  1. Insert Eyepieces: Gently insert the WH10x eyepieces into the two viewing tubes of the trinocular head.
נאָענט-אַרויף view of the two WH10x eyepieces inserted into the microscope head.

Figure 2: Eyepieces installed in the microscope head.

  1. Install Barlow Lens (Optional): If increased magnification is desired, screw the 2.0x Barlow lens onto the objective housing at the bottom of the microscope head.
Close-up of the microscope head showing the 2x/4x objective and the area for Barlow lens attachment.

Figure 3: Microscope head with objective. The Barlow lens attaches here.

  1. Attach Eye Guards: Place the rubber eye guards onto the eyepieces for comfortable viewing and to block ambient light.

אַפּערייטינג ינסטראַקשאַנז

1. אַדזשאַסטירן פאַרגרעסערונג

  • The microscope features a 2x/4x objective. Rotate the objective housing to switch between 2x and 4x magnification.
  • With the WH10x eyepieces, the base magnification is 20x (2x objective) and 40x (4x objective).
  • When the 2.0x Barlow lens is installed, the total magnification becomes 40x (2x objective * 2.0x Barlow * 10x eyepieces) and 80x (4x objective * 2.0x Barlow * 10x eyepieces).

2. פאָקוסינג

  • Place your specimen on a flat surface beneath the objective.
  • Use the bilateral focus knobs on the boom stand to raise or lower the microscope head until the specimen comes into sharp focus.

3. אַדזשאַסטירן אינטערפּופּילאַרי דיסטאַנס

  • While looking through the eyepieces, adjust the distance between the two eyepiece tubes until you see a single, circular field of view. This range is typically 47 to 75mm.

4. Dioptric Adjustment

  • Close your left eye and focus the right eyepiece using the main focus knob until the image is sharp.
  • Close your right eye and use the diopter adjustment ring on the left eyepiece to focus the image for your left eye. Do not use the main focus knob for this step.

5. Using the Trinocular Port

  • The vertical trinocular port allows for the attachment of a camera (sold separately). It is compatible with C-Mount or 23mm photo ports.
  • To use the trinocular port, pull out the light path selector rod (if present) to divert the image to the camera port.

6. ארבעטן דיסטאַנסע

  • The microscope offers a long working distance, up to 4 inches, which is beneficial for manipulating specimens under observation.
  • The 17-inch pillar provides an 8-inch vertical working distance, and the 16-inch single-arm boom has a 24-inch overall length, allowing for flexible positioning over large objects.
מיקראָסקאָפּיק view of a circuit board with solder joints, demonstrating the clarity of the microscope.

פיגורע 4: עקסample of a circuit board viewed through the microscope.

מיקראָסקאָפּיק view of several yellow insect eggs on a green surface, with a 1mm scale bar.

פיגורע 5: עקסample of insect eggs viewed through the microscope.

וישאַלט

1. רייניקן לענסעס

  • Use only specialized lens cleaning paper and lens cleaning solution.
  • Gently wipe the lens surfaces in a circular motion. Avoid touching the lenses with bare hands.
  • Never use abrasive cloths or harsh chemicals, as these can scratch or damage the optical coatings.

2. רייניקן דעם קערפער

  • ווישט דעם מיקראָסקאָפּ קערפּער מיט אַ ווייכן, טרוקענעם שטאָף.amp שטאָף.
  • For stubborn dirt, a mild detergent solution can be used, but ensure no liquid enters the internal components.

3. סטאָרידזש

  • When not in use, cover the microscope with the provided dust cover to protect it from dust and debris.
  • Store the microscope in a cool, dry place, away from direct sunlight and extreme temperatures.

4. לובריקיישאַן

  • The moving parts of the microscope are pre-lubricated. Avoid excessive lubrication.
  • If any movement becomes stiff, apply a minimal amount of light machine oil to the vertical and horizontal bars, wiping off any excess immediately.

טראָובלעשאָאָטינג

פּראָבלעם: בילד איז נישט קלאָר אָדער נישט אין פאָקוס.

  • לייזונג 1: Adjust the main focus knobs to bring the specimen into sharp focus.
  • לייזונג 2: Ensure the eyepieces are fully inserted and the interpupillary distance is correctly set for your eyes.
  • לייזונג 3: Perform dioptric adjustment for each eyepiece individually.
  • לייזונג 4: Check if the objective is clean and free from smudges or dust.

Problem: No image visible.

  • לייזונג 1: Verify that the specimen is correctly positioned under the objective.
  • לייזונג 2: Ensure the objective is rotated to a click-stop position (2x or 4x).
  • לייזונג 3: Check if the light path selector for the trinocular port is correctly set for visual observation (not diverted to a camera).

Problem: Image appears dim.

  • לייזונג 1: Ensure adequate ambient lighting is available, as this microscope uses ambient light for illumination.
  • לייזונג 2: Clean the objective and eyepiece lenses.

ספּעסאַפאַקיישאַנז

שטריךבאַשרייַבונג
קאָפּטרינאָקולאַר
פאַרגרעסערונג20x, 40x, 80x (with 2.0x Barlow)
Objective Power2 קס / 4 קס
יעפּיסעסWH10x20mm
טרינאָקולאַר פּאָרטC-Mount or 23mm
Optical Working Distanceאַרויף צו 4 אינטשעס
פעלד פון View0.787 inches at 10x
מיקראָסקאָפּ שטייןSingle-arm boom stand
קאָפּ באַוועגונגX- and Y-axes
יללומינאַטיאָן טיפּאַמביאַנט
מאַטעריאַלאָפּטיש גלאז
פּונקט וואָג3.3 פונט
מאָדעל נומערSW-3T24Z

וואָראַנטי אינפֿאָרמאַציע

The AmScope SW-3T24Z Trinocular Stereo Microscope is covered by a 5-Year Manufacturer Warranty. This warranty covers defects in materials and workmanship under normal use. For specific terms and conditions, or to make a warranty claim, please contact AmScope customer support.

שטיצן

For technical assistance, troubleshooting, or inquiries regarding your AmScope SW-3T24Z Trinocular Stereo Microscope, please contact AmScope customer support. You can find contact information and additional resources on the official AmScope website. The manufacturer is United Scope LLC.

© 2024 AmScope. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.