1. הקדמה
The Hanna Instruments HI 711 Checker HC is a handheld colorimeter designed for accurate and precise measurement of total chlorine levels. This device offers a simpler and more cost-effective alternative to chemical test kits while providing greater accuracy. It utilizes the EPA-approved DPD method 4500-Cl G, making it suitable for applications requiring this standard. This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your HI 711 Checker HC.
2. זיכערקייַט אינפֿאָרמאַציע
Please read all instructions carefully before using the HI 711 Checker HC. Failure to do so may result in inaccurate readings or damage to the device. Always handle reagents with care and follow all safety precautions provided with the reagent kits. Keep the device and reagents out of reach of children.
3. פּראָדוקט איבערview
The HI 711 Checker HC is a compact, single-button operation device featuring a large LCD screen for easy readability. It is designed for portability and ease of use in various environments.

בילד 1: The Hanna Instruments HI 711 Checker HC Handheld Colorimeter shown with a sample vial. The device displays a reading of 0.87 ppm for Total Chlorine.
די הויפּט קאַמפּאָונאַנץ אַרייַננעמען:
- LCD ווייַז: Shows measurement readings and operational prompts.
- אָפּעראַציע קנעפּל: Used for powering on/off and initiating measurements.
- Cuvette Holder: Compartment for inserting sample ווייאַלז.
- באַטערי אָפּטייל: Located at the rear for AAA battery installation.
4. סעטאַפּ
4.1 באַטאַרייע ייַנמאָנטירונג
- געפֿינען די באַטאַרייע אָפּטייל אויף די צוריק פון די מיטל.
- אַראָפּנעמען די באַטאַרייע דעקן.
- Insert one (1) AAA battery, ensuring correct polarity (+/-).
- פאַרבייַטן די באַטאַרייע דעקן סיקיורלי.
4.2 ערשט צוגרייטונג
Before first use, ensure the cuvettes are clean and free from scratches or debris. Use distilled or deionized water for rinsing.
5. אַפּערייטינג ינסטרוקטיאָנס
The HI 711 Checker HC operates using a simple, single-button interface. Follow these steps for accurate total chlorine measurements:
- מאַכט אויף: Press the button to turn the Checker HC on. The display will show "---" then "Add C1".
- Zero the Device:
- Fill a clean cuvette with 10 mL of unreacted sample water (the water you wish to test, before adding reagent).
- Cap the cuvette and wipe it thoroughly with a lint-free cloth to remove any fingerprints or smudges.
- Insert the cuvette into the Checker HC, ensuring the cap is fully seated.
- Press the button. The display will show "Add C2" when zeroing is complete.
- צולייגן רעאַגענט:
- Remove the cuvette from the Checker HC.
- Add one packet of HI 711-0 Total Chlorine reagent to the sampאין די קווועט.
- Cap the cuvette and shake gently for approximately 20 seconds to dissolve the reagent.
- Wipe the cuvette thoroughly with a lint-free cloth.
- מאָס:
- Insert the cuvette back into the Checker HC.
- Press the button. The display will show a countdown timer (e.g., "2:00"). This is the reaction time required for the DPD method.
- After the countdown, the Checker HC will display the total chlorine concentration in ppm (parts per million).
- מאַכט אַוועק: The device features an auto shut-off function to conserve battery life. It will automatically turn off after 10 minutes of inactivity. To manually turn off, press and hold the button until "OFF" is displayed.

בילד 2: The Hanna Instruments HI 711 Checker HC showing a measurement of 0.82 ppm for Total Chlorine on its LCD screen.
6. וישאַלט
6.1 רייניקונג
- Always keep the cuvettes clean. Rinse them thoroughly with distilled or deionized water after each use.
- Wipe the exterior of the Checker HC with a soft, damp שטאָף. דו זאלסט נישט נוצן אַברייסיוו קלינערז אָדער סאָלוואַנץ.
- Ensure the cuvette holder is clean and dry before storage.
6.2 סטאָרידזש
- Store the Checker HC in a cool, dry place away from direct sunlight and extreme temperatures.
- If storing for extended periods, remove the AAA battery to prevent leakage.
- Store reagents in their original packaging in a cool, dark place.
7. טראָובלעשאָאָטינג
This section addresses common issues you might encounter with your HI 711 Checker HC.
| פּראָבלעם | מעגלעך סיבה | לייזונג |
|---|---|---|
| אומגענויע אדער נישט-קאנסיסטענטע לייענונגען | Dirty cuvette, expired reagent, improper zeroing, air bubbles in sample | Clean cuvette thoroughly, use fresh reagent, ensure proper zeroing with unreacted sample, remove air bubbles by gently tapping the cuvette. |
| די מיטל טוט נישט מאַכט אויף | Dead battery, incorrect battery installation | Replace AAA battery, check battery polarity. |
| "ערר" מעסעדזש אויף דיספּליי | Measurement outside range, light interference | פאַרזיכערן סample is within the device's measurement range. Perform measurement in a stable light environment. Re-zero the device. |
8. ספּעסאַפאַקיישאַנז
The following are the technical specifications for the Hanna Instruments HI 711 Checker HC:
- מאָדעל: הי-711
- פּאַראַמעטער: גאַנץ קלאָרין
- מעטאָד: Adaptation of the EPA DPD method 4500-Cl G
- מאַכט מקור: 1 X AAA באַטערי
- פּראָדוקט דימענשאַנז: 5 X 3 X 4 אינטשעס
- וואָג: 8.82 אונסעס
- אַוטאָ פאַרמאַכן-אַוועק: נאָך 10 מינוט פון ינאַקטיוויטי
9. וואָראַנטי אינפֿאָרמאַציע
Hanna Instruments products are warranted against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. The specific warranty period may vary by region and product. Please refer to the warranty card included with your product or visit the official Hanna Instruments webזייטל פֿאַר דעטאַלירטע וואָראַנטי טערמינען און באַדינגונגען. האַלט דיין באַווייַז פון קויפן פֿאַר וואָראַנטי קליימז.
10. קונה שטיצן
For technical assistance, troubleshooting, or information regarding reagents and accessories, please contact Hanna Instruments customer support. You can find contact details on the official Hanna Instruments website or through your local distributor. When contacting support, please have your product model number (HI-711) and purchase date available.