Murray MP120AFC

Murray MP120AFC 20-Amp 1 Pole 120-Volt Combination Type Arc Fault Circuit Interrupter User Manual

Model: MP120AFC

1. הקדמה

This manual provides essential information for the safe installation, operation, and maintenance of the Murray MP120AFC 20-Amp 1 Pole 120-Volt Combination Type Arc Fault Circuit Interrupter (AFCI). Please read this manual thoroughly before installation or use to ensure proper function and safety. This device is designed to detect and mitigate the effects of arc faults, which can be a cause of electrical fires.

2. זיכערקייַט אינפֿאָרמאַציע

ווארענונג: ריזיקע פון ​​עלעקטרישן שאק אדער פייער

  • Installation and servicing must be performed by qualified electrical personnel only.
  • Always turn off power at the main service panel before working on electrical circuits or installing this device.
  • ניצן צונעמען פערזענלעכע פּראַטעקטיוו עקוויפּמענט (פּפּע).
  • Ensure all wiring connections are secure and meet local and national electrical codes.
  • דו זאלסט נישט נוצן דעם מיטל אויב עס איז דאַמידזשד.

3. פּראָדוקט איבערview

The Murray MP120AFC is a single-pole, 20-Amp, 120-Volt Combination Type Arc Fault Circuit Interrupter designed for use in Murray load centers or meter combinations. It provides protection against both parallel and series arc faults, as well as overcurrent protection. The breaker features a test button for verifying proper operation.

Murray MP120AFC Arc Fault Circuit Interrupter

פיגורע 1: Illustrative image of a Murray Arc Fault Circuit Interrupter. Note: This image displays a 15-Amp version for visual reference; the product covered by this manual is a 20-Amp model (MP120AFC). The image shows the main body of the circuit breaker, including the toggle switch, the blue 'TEST' button, and various labels indicating specifications like 'MURRAY', 'ARC FAULT', 'AFCI', 'Interrupting Rating 22kA 120V~', and wiring instructions. A coiled white pigtail wire is visible at the bottom.

4. סעטאַפּ און ייַנמאָנטירונג

גיי די סטעפּס פֿאַר געהעריק ינסטאַלירונג:

  1. מאַכט דיסקאַנעקשאַן: Turn off the main power to the electrical panel at the service entrance. Verify power is off using a voltagE tester.
  2. אידענטיפיצירן סלאָט: Locate an available slot in the Murray load center.
  3. Connect Pigtail: Connect the white pigtail wire from the AFCI to the neutral bar in the load center. Ensure a secure connection.
  4. אינסטאַלירן ברעיקער: Hook the rear of the breaker onto the bus bar stab and firmly push the front of the breaker down until it is fully seated in the panel.
  5. Connect Circuit Wire: Connect the circuit's hot (black) wire to the terminal screw on the AFCI. Tighten the screw to the torque specified on the breaker label (e.g., 25 lb-in for 60/75°C wire, AWG CU #14-8 / AL #12-8).
  6. Connect Circuit Neutral: Connect the circuit's neutral (white) wire to the designated terminal on the AFCI, not the neutral bar.
  7. ומקערן מאַכט: Once all connections are secure and verified, close the panel cover and restore power at the main service entrance.

5. אַפּערייטינג ינסטרוקטיאָנס

The AFCI operates automatically to protect against arc faults and overcurrents. It has a toggle switch for manual operation and a test button.

5.1 טורנינג אויף / אַוועק

  • To turn the circuit ON, push the toggle switch firmly to the 'ON' position.
  • To turn the circuit OFF, push the toggle switch firmly to the 'OFF' position.

5.2 Testing the AFCI

It is recommended to test the AFCI monthly to ensure proper operation.

  1. זיכער מאַכן אַז דער קרייַז ברעאַקער איז אין דער 'ON' פּאָזיציע.
  2. Press the 'TEST' button (typically blue) located on the front of the breaker.
  3. The breaker should immediately trip to the 'TRIPPED' (center) position. This indicates the AFCI is functioning correctly.
  4. To reset the breaker, push the toggle switch firmly to the 'OFF' position, then back to the 'ON' position.
  5. If the breaker does not trip when the 'TEST' button is pressed, or if it does not reset, contact a qualified electrician for inspection and replacement if necessary.

6. וישאַלט

The Murray MP120AFC is designed for maintenance-free operation. Regular testing as described in Section 5.2 is the primary maintenance requirement. Keep the area around the electrical panel clean and free from obstructions. Do not attempt to open or repair the circuit breaker.

7. טראָובלעשאָאָטינג

פּראָבלעםמעגלעך סיבהלייזונג
ברעאַקער טריפּס אָפטArc fault detected, Overload, Short circuit, Ground faultUnplug appliances from the circuit. If it still trips, contact a qualified electrician to inspect wiring for arc faults, overloads, or short circuits.
ברעיקער ריסעט נישטPersistent fault, Internal breaker failureEnsure all loads are disconnected. If it still won't reset, contact a qualified electrician.
טעסט קנעפל טוט נישט אויסלעשן די ברעיקערAFCI malfunctionThe AFCI may be faulty. Contact a qualified electrician for replacement.

8. ספּעסאַפאַקיישאַנז

  • סאָרט: מוריי
  • מאָדעל: MP120AFC
  • איצטיקע רייטינג: 20 Amps
  • Voltage: 120 וואלטס
  • נומער פון פּויליש: 1
  • קרייַז צוימען טיפּ: Combination Type AFCI (Arc Fault Circuit Interrupter)
  • מאַונטינג טיפּ: פּלוג-אין בארג
  • ינטעראַפּטינג שאַץ: 22kA
  • אָפטקייַט: 50/60 הז
  • דראָט קאַמפּאַטאַבילאַטי: CU #14-8 / AL #12-8
  • טאָרק שאַץ: 25 lb-in (for wire terminals)
  • דימענסיעס: בעערעך 1 X 4 X 3 אינטשעס
  • וואָג: בעערעך 1.6 אונסעס
  • סערטיפיקאַטיאָנס: UL ליסטעד

9. וואָראַנטי און שטיצן

Specific warranty details for the Murray MP120AFC are typically provided at the point of purchase or on the product packaging. For warranty claims or technical support, please contact Murray customer service or refer to the official Murray website. Always ensure that any servicing or inspection is carried out by a qualified professional.

© 2023 Murray. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.