Orbit 57114 4-Station Standard Indoor Sprinkler System Control Timer User Manual

מאָדעל: 57114

הקדמה

This manual provides instructions for the installation, programming, operation, and maintenance of your Orbit 57114 4-Station Standard Indoor Sprinkler System Control Timer. Please read this manual thoroughly before installation and use to ensure proper function and longevity of your device.

Orbit 57114 4-Station Sprinkler Timer front view

בילד: פראָנט view of the Orbit 57114 4-Station Standard Indoor Sprinkler System Control Timer, showing the digital LCD screen and control dial.

פּראָדוקט פֿעיִקייטן

  • 4 Watering Stations: Manages up to four independent watering zones.
  • 2 פּראָגראַמען: Allows for two distinct watering schedules (Program A and Program B).
  • פלעקסיבלע סקעדזשולינג: Set watering based on specific days of the week or intervals from 1 to 28 days.
  • Adjustable Watering Duration: Water for 1 to 99 minutes per station.
  • Multiple Start Times: Up to 8 start times per program, ideal for new lawns or drip irrigation to prevent runoff.
  • דיגיטאַל לקד פאַרשטעלן: Provides clear display for easy programming and operation.
  • Indoor Mounted Design: Specifically designed for indoor installation.

פּעקל אינהאַלט

באַשטעטיקן אַז אַלע קאָמפּאָנענטן זענען פאַראַן איידער איר הייבט אָן די אינסטאַלאַציע:

  • Orbit 57114 4-Station Sprinkler Timer Unit
  • Power Adapter (Transformer)
  • Mounting Hardware (screws and wall anchors) - Note: Some packages may not include screws; ensure you have appropriate hardware for mounting.
  • באַניצער מאַנואַל (דעם דאָקומענט)

ייַנמאָנטירונג

1. מאָנטירן דעם טייַמער

  1. Select an indoor location near a standard electrical outlet and away from direct sunlight, heat, or freezing temperatures.
  2. Use the provided mounting template (if available) or mark two mounting holes on the wall, ensuring they are level.
  3. Drill pilot holes and insert wall anchors if mounting into drywall.
  4. Insert screws into the upper mounting holes, leaving a small gap between the screw head and the wall.
  5. Hang the timer unit onto the upper screws using the keyhole slots on the back.
  6. Secure the timer by inserting a screw through the lower mounting hole and tightening all screws.

2. Wiring the Valves

Each sprinkler valve has two wires. One wire from each valve is a common wire, and the other is a specific zone wire.

  1. Strip approximately 1/2 inch of insulation from the ends of all valve wires.
  2. Connect all common wires from your valves to the terminal labeled "COMMON" or "C" on the timer.
  3. Connect each individual zone wire to its corresponding station terminal (e.g., Station 1 to "1", Station 2 to "2", etc.).
  4. ענשור אַז אַלע דראָט קאַנעקשאַנז זענען זיכער.

3. קאַנעקטינג מאַכט

Connect the power adapter to the timer's power input jack, then plug the adapter into a standard 120V AC electrical outlet. The timer display should illuminate.

סעטאַפּ און פּראָגראַממינג

The Orbit 57114 timer features a digital LCD screen and a control dial for easy navigation and programming.

1. Set Current Time and Day

  1. דריי דעם קנעפּל צו "שטעלן די זייגער".
  2. ניצן די + און - buttons to adjust the hour, then press "NEXT" or "ENTER" (button names may vary slightly) to move to minutes.
  3. Adjust minutes, then press "NEXT" or "ENTER" to set AM/PM.
  4. Continue to set the current day of the week.

2. Program Watering Schedules (A and B)

The timer allows for two independent programs, A and B. Each program can have up to 8 start times.

  1. אויסקלייַבן פּראָגראַם: Turn the dial to "PROGRAM A" or "PROGRAM B".
  2. Set Start Times:
    • Turn the dial to "START TIMES".
    • ניצן + און - buttons to set the desired start time for the first cycle. Press "NEXT" or "ENTER".
    • Repeat for up to 8 start times. To disable a start time, set it to "OFF".
  3. שטעלן וואַסערונג געדויער:
    • Turn the dial to "RUN TIME".
    • Select the station (1-4) you wish to program.
    • ניצן + און - buttons to set the watering duration (1 to 99 minutes) for that station.
    • Press "NEXT" or "ENTER" to move to the next station. Repeat for all active stations.
  4. Set Watering Days:
    • Turn the dial to "HOW OFTEN".
    • Choose your preferred scheduling method:
      • טעג פון דער וואָך: Select specific days (e.g., Mon, Wed, Fri) using the + און - buttons to toggle days ON/OFF.
      • ינטערוואַלז: Set an interval (e.g., every 2 days, every 3 days) from 1 to 28 days.

3. Activate Program

After programming, turn the dial to "AUTO" to enable the automatic watering schedule. The timer will now operate according to your set programs.

אָפּעראַציע

אָטאַמאַטיק אָפּעראַציע

When the dial is set to "AUTO", the timer will automatically activate your programmed watering schedules (Program A and Program B) at their designated start times, for the specified durations, and on the selected days or intervals.

Manual Operation (Water Now)

צו מאַנועל וואַסערן אַ סטאַנציע אָדער אַלע סטאַנציעס:

  1. Turn the dial to "MANUAL".
  2. ניצן די + און - buttons to select the station you wish to water manually.
  3. Press "NEXT" or "ENTER" to confirm.
  4. Set the desired watering duration for the manual cycle.
  5. The selected station will begin watering immediately. To stop manual watering, turn the dial back to "AUTO" or "OFF".

וישאַלט

The Orbit 57114 timer requires minimal maintenance. Ensure it remains in a dry, indoor environment. Periodically check wire connections for corrosion or looseness. If the display fades or the timer behaves erratically, ensure the power adapter is securely connected and functioning correctly.

טראָובלעשאָאָטינג

  • Timer Display is Blank:
    • Check if the power adapter is securely plugged into both the timer and the electrical outlet.
    • באַשטעטיקן אַז די עלעקטרישע אַוטלעט אַרבעט דורך אַרײַנשטעקן אַן אַנדער אַפּאַראַט.
  • Sprinklers Do Not Turn On:
    • Ensure the dial is set to "AUTO" for automatic operation.
    • Check that watering programs (A or B) are enabled and have valid start times, run times, and watering days/intervals.
    • Inspect all wiring connections to the valves and the common terminal for security.
    • Manually test each station using the "MANUAL" function to confirm valve functionality.
    • Verify that the main water supply to your sprinkler system is turned on.
  • Only Some Sprinklers Turn On:
    • Check the wiring for the non-functioning stations. Ensure the zone wire is properly connected to its terminal.
    • Verify the common wire connection is secure for all valves.
    • Confirm that the run time is set for the affected stations in the active program.
  • Timer is Not Keeping Time:
    • Ensure the power supply is stable. Power interruptions can affect timekeeping.
    • Re-set the current time and day.

For further assistance, refer to the detailed troubleshooting guide on the Orbit webפּלאַץ אָדער קאָנטאַקט קונה שטיצן.

ספּעסאַפאַקיישאַנז

שטריך דעטאַל
מאָדעל נומער 57114
נומער פון סטאַנציעס 4
מגילה 2 (Program A, Program B)
Start Times per Program אַרויף צו 8
וואָטערינג געדויער 1 צו 99 מינוט
וואָטערינג אָפטקייַט Days of the week or intervals (1-28 days)
ייַנמאָנטירונג דרינענדיק מאָונטעד
מאַכט אַרייַנשרייַב 120V AC (דורך די אַרייַנגעשלאָסענע אַדאַפּטער)
מאַטעריאַל מעטאַל, פּלאַסטיק
פּונקט וואָג 16 אונסעס (בעערעך)
סמאַרט היים קאַמפּאַטאַבילאַטי Not Smart Home Compatible

וואָראַנטי און שטיצן

For information regarding product warranty, technical support, or replacement parts, please contact Orbit customer service directly. Refer to the packaging or the official Orbit webזייטל פֿאַר די מערסט אַקטועלע קאָנטאַקט אינפֿאָרמאַציע און וואָראַנטי דעטאַלן.

Orbit Customer Support: www.orbitonline.com/support

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.